Plan Review Details - Permit 10040029
Plan Review Stops For Permit 10040029
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2010-04-06 Cont ID  
Sent By jwitmer Date 2010-04-06 Time 13:23 Rev Time 0.77
Received By jwitmer Date 2010-04-06 Time 13:23 Sent To  
Notes
2010-04-06 13:43:41BUILDING PLAN REVIEW
 PERMIT: 10040029
 ADD: 1801 S FLAGLER# 1404
 CONT: PHILIP E. JOHNSON, INC.
 TEL: (561)662-8656
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 BUILDING APPROVED WITH EXCEPTION!
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S).
  
  
 1) MISSING INFORMATION ON STRUCTURE-BORNE SOUND
 INSULATION.
 1207.3 STRUCTURE-BORNE SOUND. FLOOR/CEILING ASSEMBLIES
 BETWEEN DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A
 PUBLIC OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE
 AN IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS
 THAN 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE
 WITH ASTM E 492.
  
 2) 603.1 ALLOWABLE MATERIALS. COMBUSTIBLE MATERIALS
 SHALL BE PERMITTED IN BUILDINGS OF TYPE I OR TYPE II
 CONSTRUCTION IN THE FOLLOWING APPLICATIONS AND IN
 ACCORDANCE WITH SECTIONS 603.1.1 THROUGH 603.1.3:
  
 1. FIRE-RETARDANT-TREATED WOOD SHALL BE PERMITTED IN:
  
 1.1. NONBEARING PARTITIONS WHERE THE REQUIRED
 FIRE-RESISTANCE RATING IS 2 HOURS OR LESS.
  
 JIM WITMER C. B. O.
 COMMERCIAL COMBINATION PLAN REVIEW
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2010-04-09 Cont ID  
Sent By btrobaug Date 2010-04-09 Time 15:29 Rev Time 0.00
Received By btrobaug Date 2010-04-09 Time 15:15 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2010-04-14 Cont ID  
Sent By mawillia Date 2010-04-14 Time 16:43 Rev Time 0.00
Received By mawillia Date 2010-04-14 Time 16:37 Sent To  
Notes
2010-04-14 16:40:45*****APPROVED*****
  
 PLAN SHEET A-1 (1 OF 01) STAMPED, INITIALED, AND DATED.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2010-04-15 Cont ID  
Sent By jwitmer Date 2010-04-15 Time 07:48 Rev Time 0.00
Received By jwitmer Date 2010-04-01 Time 16:46 Sent To  
Notes
2010-04-05 16:47:08B--2

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2010-04-06 Cont ID  
Sent By hmoser Date 2010-04-06 Time 14:09 Rev Time 0.00
Received By hmoser Date 2010-04-06 Time 14:09 Sent To  
Notes
2010-04-06 14:15:50PASS PROVISO
 PLEASE PROVIDE THE DUCT SIZE OF THE TWO 24X12 RETURN
 AIR ON THE PLANS FOR THE 1ST INSPECTION
 PLAN REVIEW BY HAROLD MOSER 561-805-6732

Review Stop P PLUMBING
Rev No 1 Status P Date 2010-04-14 Cont ID  
Sent By lwagner Date 2010-04-14 Time 13:17 Rev Time 0.00
Received By lwagner Date 2010-04-14 Time 13:17 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status N Date 2010-04-07 Cont ID  
Sent By eschneid Date 2010-04-07 Time 10:22 Rev Time 0.00
Received By eschneid Date 2010-04-07 Time 10:22 Sent To  
Notes
2010-04-07 10:22:37LESS THAN 50% VALUE OF UNIT.