Plan Review Details - Permit 10030636
Plan Review Stops For Permit 10030636 |
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2010-04-09 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2010-04-09 |
Time |
15:04 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2010-04-09 |
Time |
14:40 |
Sent To |
|
|
Notes |
2010-04-09 14:59:05 | *****APPROVED***** | | | | | | THE COMMENTS FROM THE PREVIOUS REVIEW HAVE BEEN | | ADDRESSED. THE FIRE ALARM PLAN (SHEETS FP1, FP2, & FP3) | | FIRE-STAMPED ACCORDINGLY; READY FOR PERMIT ISSUANCE. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2010-03-30 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2010-03-30 |
Time |
15:56 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2010-03-30 |
Time |
15:23 |
Sent To |
|
|
Notes |
2010-03-30 15:56:39 | | | 3415 SOUTH DIXIE HIGHWAY | | PERMIT NUMBER 10030636 | | FIRE SPRINKLER SYSTEM INSTALLATION FOR NEW TWO-STORY | | BUILDING | | WIGINTON FIRE SYSTEMS | | | | | | 1. KNOX LOCKING CAPS NEEDED FOR THE FIRE DEPARTMENT | | CONNECTION (FDC) . BREAKAWAY CAPS ILLUSTRATED ON PAGE | | FP1. | | | | 2. CHAIN AND LOCK REQUIRED ON BACKFLOW DEVICE IN | | ADDITION TO THE TAMPER SWITCHES. | | | | 3. SITE PLAN DOES NOT ILLUSTRATE ANY NEW OR EXISTING | | FIRE HYDRANTS. THE FIRE DEPARTMENT CONNECTION (FDC) | | SHALL BE WITHIN 150 FEET OF A FIRE HYDRANT. | | | | 4. WRONG EDITION OF NFPA 13 NOTED ON PAGE FP2. IT | | SHOULD READ NFPA 13, 2002 EDITION. | | | | 5. ON PAGE FP2 AND FP3, 1 -1/4" BRANCH LINES NOT | | SUPPORTED BY HYDRAULIC CALCULATIONS. | | | | 6. SEVEN FIRE SPRINKLERS LOCATED ON 36' OF BRANCH LINE | | ON FP2 OF THREE. THIS ARRANGEMENT IS NOT SUPPORTED BY | | THE HYDRAULIC CALCULATIONS. | | | | 7. THE THREE FIRE SPRINKLER HEADS UNDERNEATH THE STAIRS | | ARE SUPPLIED BY A 1" PIPE. THIS ARRANGEMENT IS NOT | | SUPPORTED BY THE HYDRAULIC CALCULATIONS. | | | | 8. ARCHITECTURAL ELEMENTS OR SOFFITS SHALL NOT | | INTERFERE WITH THE SPRAY PATTERN OF ANY FIRE SPRINKLER | | HEADS. | | | | | | DENIED | | | | | | MIKE CARSILLO, BATTALION CHIEF | | BUREAU OF FIRE PREVENTION | | (561) 804-4724 PHONE | | (561) 804-4774 FAX | | | | WESLEY JOLIN, FIRE PROTECTION ENGINEER | | BUREAU OF FIRE PREVENTION | | (561) 805-6730 PHONE | | (561) 804-4774 FAX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2010-04-06 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2010-04-06 |
Time |
12:17 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2010-04-06 |
Time |
12:16 |
Sent To |
FIRE |
|
Notes |
2010-04-06 12:16:55 | TO FIRE BOX./WRT |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2010-04-06 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2010-04-06 |
Time |
12:16 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2010-03-24 |
Time |
11:03 |
Sent To |
|
|
Notes |
2010-04-06 12:16:03 | FIRST "I" STOP NOT CLOSED, I,M CLOSINNG AND ENTERING | | RESUB./WRT. | 2010-03-25 11:03:58 | IN FIRE BOX |
|
|
|