Plan Review Stops For Permit 10030504 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2011-01-05 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2011-01-05 |
Time |
10:22 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2011-01-05 |
Time |
10:22 |
Sent To |
P |
|
Notes |
2011-01-05 10:48:52 | ****PROVISOS**** | | ****ISSUED AT CONTRACTOR'S RISK**** | | ****REVISION REQUIRED**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2007 | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | 1. ACCESSIBLE ENTRANCE DOOR TO COMPLY WITH MANEUVERING | | CLEARANCE, FBC 11 FIGURE 25, PULL SIDE. | | | | 2. REVISE PLAN TO PROVIDE A RAMP DETAIL WHICH COMPLIES | | WITH ALL REQUIREMENTS OF FBC 11 4.8. REVISION IS | | REQUIRED PRIOR TO FIRST INSPECTION. FOR EXAMPLE, DETAIL | | SHOWN DOES NOT SHOW COMPLIANCE (OR DETAIL IS NON | | COMPLIANT) WITH REQUIREMENTS SUCH AS EDGE PROTECTION, | | RAMP LANDING AT BOTTOM, DOOR MANEUVERING CLEARANCE, | | RAMP RISE. | | | | 3. CLARIFY BUILDING TYPE ON PLAN, II B STATED; NON | | COMBUSTIBLE, SEE FBC CHAPTER 6. | | | | 4. PORCH ENCLOSURE STRUCTURAL DETAIL (PREPARED BY | | STEVEN WALSH, PE) TO BE REVIEWED BY ENGINEER OF RECORD | | (BERT BEJARANO, PE). | | | | 5. ACCESSIBLE BATH SHOWN ON FLOOR PLAN CONFLICTS WITH | | THE DETAIL MARKED "ACCESSIBLE RESTROOM REQUIREMENTS." | | SCOPE OF WORK COVERED UNDER THIS PERMIT IS NOT CLEAR. | | REVISE PLAN TO SHOW WORK TO BE INCLUDED IN THIS PERMIT | | AND REVISE DETAILS AS NECESSARY.6. | | | | 6. SUBMIT DOOR PRODUCT APPROVAL. THIS SHOULD BE | | REVIEWED BY ENGINEER OF RECORD PRIOR TO SUBMITTAL. | | ENGINEER TO SPECIFY DESIGN PRESSURES. | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2010-07-28 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2010-07-28 |
Time |
17:40 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2010-07-28 |
Time |
17:40 |
Sent To |
|
|
Notes |
2010-07-28 17:43:16 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2007 | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | 1. PLEASE SUBMIT A COST BREAKDOWN FOR THIS PROJECT, | | FBC11-4.1.6(2). THIS HAS BEEN DISCUSSED WITH THE | | ENGINEER. | | | | 2. PROVIDE THE IMPACT FEE RECEIPT SHOWING THAT THE | | IMPACT FEES HAVE BEEN PAID. | | | | 3. PLEASE CLARIFY SCOPE OF WORK. IS THE "ACCESSIBLE | | BATH" INCLUDED IN THE SCOPE? OUR RECORDS SHOW THAT THE | | ACCESSIBLE BATHROOM PERMIT WAS APPLIED FOR BUT NOT | | ISSUED. IF IT WAS NOT PERMITTED, IT IS NOT CONSIDERED | | "EXISTING." | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2010-06-21 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2010-06-21 |
Time |
14:56 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2010-06-21 |
Time |
14:56 |
Sent To |
E |
|
Notes |
2010-06-21 15:08:39 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2007 | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | 1. PLEASE SUBMIT A FLOOR PLAN AND SITE PLAN SHOWING | | COMPLIANCE WITH FBC EXISTING BUILDING CODE CHAPTER 9, | | CHANGE OF OCCUPANCY FROM R3 (RESIDENTIAL) TO B | | (BUSINESS). | | | | 2. PROVIDE THE IMPACT FEE RECEIPT SHOWING THAT THE | | IMPACT FEES HAVE BEEN PAID. | | | | | | | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2010-05-12 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2010-05-12 |
Time |
10:28 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2010-05-12 |
Time |
10:28 |
Sent To |
|
|
Notes |
2010-05-12 10:45:32 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2007 | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | 1. IMPACT FEES MAY BE DUE TO PALM BEACH COUNTY. BASED | | ON OUR RECORDS, THIS IS NEW UNDER AIR SPACE (PREVIOUSLY | | A CARPORT). PLEASE CONTACT 233-5025 FOR MORE | | INFORMATION. THE PLANS ARE TO BE STAMPED AND THE | | RECEIPT ATTACHED TO THE APPLICATION. | | | | 2. IT APPEARS THAT THERE HAS BEEN A CHANGE OF OCCUPANCY | | AT THIS ADDRESS. PLEASE SUBMIT A PLAN WHICH SHOWS | | COMPLIANCE WITH CHANGE OF OCCUPANCY REQUIREMENTS, FBC | | EXISTING BUILDING CODE CHAPTER 9. SEE ALSO COMMENT #1. | | | | 3. PER ABO, PLEASE PROVIDE INFORMATION REGARDING THE | | EXISTING SUBSTRATE. THIS INFORMATION IS REQUIRED TO | | DETERMINE THE EFFECT OF THE INFILL WALL ON THE EXISTING | | STRUCTURE. | | | | 4. THERE ARE THREE EXPIRED PERMITS FOR THIS ADDRESS. | | PLEASE ADDRESS. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2010-03-23 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2010-03-23 |
Time |
11:45 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2010-03-23 |
Time |
11:45 |
Sent To |
Z |
|
Notes |
2010-03-23 12:32:57 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2007 | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | 1. DUE TO THE PROXIMITY TO THE INTRACOASTAL, THIS | | PARCEL IS LOCATED IN EXPOSURE C (DOES NOT HAVE 1500 | | FEET OF STRUCTURES IN ALL DIRECTIONS). PLEASE REVISE. | | | | 2. PROVIDE FLORIDA STATE OR LOCAL PRODUCT APPROVALS FOR | | THE DOORS, FAC9B72. THEY ARE TO BE REVIEWED BY DESIGNER | | OF RECORD PRIOR TO SUBMITTAL. | | | | 3. PLANS STATE THAT THIS STRUCTURE IS A CBS RESIDENCE, | | BUT OUR RECORDS SHOW THIS AS AN OFFICE (AND FLOOR PLAN | | STATES THIS IS AN OFFICE). PLEASE DECLARE OCCUPANCY | | CLASSIFICATION FBC CHAPTER 3. | | | | 4. IT IS NOT CLEAR HOW THIS IMPROVEMENT WILL AFFECT | | ACCESSIBILITY, FBC11-4.1(A). ALSO SEE FBC1008.1.4. | | | | 5. DECLARE LEVEL OF ALTERATION FBC EXISTING BUILDING | | 401.4. | | | | 6. PLEASE PROVIDE A WALL SECTION INCLUDING INTERIOR | | HEIGHT FBC1003.2. NO HURRICANE CONNECTORS ARE SHOWN, | | BUT IT APPEARS THAT A NEW INFILL WALL IS PROPOSED, IS | | THIS CORRECT? SCOPE NOT CLEAR FBC106, FBC1609. | | | | 7. DOOR SIZE NOT CLEAR, SEE FBC1008.1.1. THE PLAN | | STATES THAT THIS IS A 3' DOOR BUT MASONRY OPENING IS TO | | BE 2'9". IS THE DOOR TO BE INSTALLED IN A MASONRY WALL | | OR FRAME WALL? PROVIDE A DETAIL FOR THE NEW DOOR | | OPENING. | | | | 8. IF IT IS DETERMINED THAT THIS WAS ENCLOSED WITHOUT A | | PERMIT, IMPACT FEE ASSESSMENT FROM PALM BEACH COUNTY | | WILL BE REQUIRED. 561-233-5025. | | | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
N |
Date |
2010-08-09 |
|
|
Cont ID |
|
Sent By |
dwise |
Date |
2010-08-09 |
Time |
11:12 |
Rev Time |
0.00 |
Received By |
dwise |
Date |
2010-08-09 |
Time |
11:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
N |
Date |
2010-06-22 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2010-06-22 |
Time |
11:53 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2010-06-22 |
Time |
11:53 |
Sent To |
|
|
Notes |
2010-06-22 11:55:03 | NO ELECTRICAL PLANS WERE SUBMITTED IF ELECTRICAL WORK | | IS TO BE DONE A PERMIT IS REQUIRED./WRT. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2010-12-27 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2010-12-27 |
Time |
15:37 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2010-12-27 |
Time |
15:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2010-07-29 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2010-07-29 |
Time |
15:29 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2010-07-29 |
Time |
14:14 |
Sent To |
|
|
Notes |
2010-07-29 15:29:14 | *****REVIEW COMMENTS - FIRE ***** | | | | 1) ADD FLORIDA FIRE PREVENTION CODE 2007 EDITION (NFPA | | 1 & NFPA 101) TO THE CODE LIST. | | | | 2) PROVIDE BUILDING ADDRESS HAVING NUMBERS CONTRASTING | | WITH THEIR BACKGROUND. NUMERALS SHALL BE NOT LESS THAN | | SIX-INCHES IN HEIGHT AND VISISBLE FROM THE ROAD (NFPA | | 1, SECTION 10.12.1). | | | | 3) RAMPS SHALL HAVE HANDRAILS (NFPA 101, SECTION | | 7.2.2.4.1). PROVIDE RAMP DETAILS. | | | | 4) OUTSIDE RAMPS AND LANDINGS SHALL BE DESIGNED TO | | MINIMIZE WATER ACCUMULATION ON THEIR SURFACES (NFPA | | 101, SECTION 7.2.5.6.2). | | | | 5) PROVIDE TACTILE SIGNAGE AT EXITS (NFPA 101, SECTION | | 7.10.1.3). | | | | 6) PROVIDE EXIT SIGNS WITH DIRECTIONAL CHEVRONS AND | | ORIENT SIGNS SO THEY ARE VISIBLE (NFPA 101, SECTIONS | | 7.10.1.8 AND 7.10.2). | | | | 7) THE PORCH IS BEING SHOWN AS AN EXIT. IS THE PORCH | | ENCLOSED? | | | | 8) PROVIDE INFORMATION AS TO WHERE THE EXITS DISCHARGE | | TO THE EXTERIOR OF THE BUILDING. | | | | 9) PROVIDE INFORMATION AS TO THE TYPES OF | | LOCKING/LATCHING MECHANISMS BEING USED ON THE EXIT | | DOORS. | | | | 10) PROVIDE PORTABLE FIRE EXTINGUISHERS PER NFPA 10. | | | | 11) PROVIDE INFORMATION ON SMOKE DETECTORS SHOWN ON | | PLAN. ARE THE DEVICES SMOKE ALARMS OR SMOKE DETECTORS? | | ARE THEY BATTERY OPERATED OR POWERED BY THE BUILDING? | | | | 12) PROVIDE FURNITURE/EQUIPMENT LAYOUT FOR FILE ROOM, | | RECEPTION, ENTRY FOYER AND CONFERENCE ROOM. | | | | 13) DOORS SWINGS BETWEEN TWO OFFICES AND "ACCESSIBLE | | BATH" BLOCKS EXIT ACCESS PATH. | | | | MIKE CARSILLO, BATTALION CHIEF | | & WESLEY JOLIN | | FIRE PLAN REVIEW | | 561-805-6730 |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
3 |
Status |
P |
Date |
2011-01-03 |
|
|
Cont ID |
|
Sent By |
jpapa |
Date |
2011-01-03 |
Time |
09:49 |
Rev Time |
0.00 |
Received By |
jpapa |
Date |
2011-01-03 |
Time |
09:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
P |
Date |
2010-05-10 |
|
|
Cont ID |
|
Sent By |
jpapa |
Date |
2010-05-10 |
Time |
15:13 |
Rev Time |
0.00 |
Received By |
jpapa |
Date |
2010-05-10 |
Time |
15:12 |
Sent To |
|
|
Notes |
2010-05-10 15:14:51 | REVISION REVIEWED AND APPROVED BY HISTORIC ON 4/28/2010 | | BY J. PAPA. | | JILLIAN PAPA | | HISTORIC PRESERVATION PLANNER | | 561-822-1454 |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
F |
Date |
2010-04-21 |
|
|
Cont ID |
|
Sent By |
jpapa |
Date |
2010-04-21 |
Time |
14:56 |
Rev Time |
0.00 |
Received By |
jpapa |
Date |
2010-04-21 |
Time |
14:55 |
Sent To |
|
|
Notes |
2010-04-20 12:05:18 | 4/20/2010 | | FAILED. THE APPLICANT HAS NOT OBTAINED APPROVAL FROM | | THE HISTORIC PRESERVATION DIVISION FOR EXTERIOR WORK. | | CONTACT JILLIAN PAPA, HISTORIC PRESERVATION PLANNER, AT | | 822-1454 FOR MORE INFORMATION. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2011-01-06 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2011-01-06 |
Time |
13:40 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2010-12-14 |
Time |
15:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2010-07-23 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2010-07-23 |
Time |
11:10 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2010-07-23 |
Time |
11:10 |
Sent To |
|
|
Notes |
2010-07-28 17:31:59 | C 20 | | (INCLUDED CHANGE OF OCCUPANCY WITH RESUBMITTAL) | | | | | 2010-07-23 11:11:02 | GAVE TO SAMANTHA |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2010-06-15 |
|
|
Cont ID |
|
Sent By |
vmolina |
Date |
2010-06-15 |
Time |
09:26 |
Rev Time |
0.00 |
Received By |
vmolina |
Date |
2010-06-15 |
Time |
09:26 |
Sent To |
|
|
Notes |
2010-06-21 11:22:06 | 6/21 TO SH DESK | | | | | 2010-06-15 09:26:25 | IN ZONING BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2010-04-14 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2010-04-14 |
Time |
14:59 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2010-04-14 |
Time |
14:58 |
Sent To |
|
|
Notes |
2010-04-14 14:59:06 | INCOMING SENT TO ZONING |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2010-03-23 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2010-03-23 |
Time |
12:33 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2010-03-18 |
Time |
11:18 |
Sent To |
|
|
Notes |
2010-03-22 13:18:09 | UNDER 5 K BLDG. |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2011-01-05 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2011-01-05 |
Time |
08:06 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2011-01-05 |
Time |
08:06 |
Sent To |
|
|
Notes |
2011-01-05 09:20:49 | MU-2010-011022-0000 | | IMPACT FEE RECEIPT (CHANGE OF OCCUPANCY FROM R3 TO B) |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2010-06-21 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2010-06-21 |
Time |
15:15 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2010-06-21 |
Time |
15:15 |
Sent To |
|
|
Notes |
2010-06-21 15:17:00 | PROVIDE IMPACT FEE RECEIPT | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2010-08-09 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2010-08-09 |
Time |
10:10 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2010-08-09 |
Time |
10:01 |
Sent To |
|
|
Notes |
2010-08-09 10:12:11 | NO PLANS SUBMITTED FOR REVIEW |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
N |
Date |
2011-01-06 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2011-01-06 |
Time |
07:53 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2011-01-06 |
Time |
07:53 |
Sent To |
|
|
Notes |
2011-01-06 08:00:00 | FBC PLUMBING 2007 403.1 | | REQUIRED DRINKING FOUNTAIN WAS NOT | | INCLUDED WITH THESE PLANS. SEPERATE | | PLUMBING APPLICATION, ISO DRAWING, | | AND PERMIT IS REQUIRED. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2010-08-03 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2010-08-03 |
Time |
10:01 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2010-08-02 |
Time |
14:34 |
Sent To |
|
|
Notes |
2010-08-02 15:20:38 | *******PROVISO******* | | | | PLUMBING PERMIT REQUIRED. | | PLUMBING RISER DIAGRAM REQUIRED | | | | 1. WITH A CHANGE OF OCCUPANCY TO BUSINESS A DRINKING | | FOUNTAIN WILL BE REQUIRED. | | 403.1 MINIMUM NUMBER OF FIXTURES. PLUMBING FIXTURES | | SHALL BE PROVIDED FOR THE TYPE OF OCCUPANCY AND IN THE | | MINIMUM NUMBER SHOWN IN TABLE 403.1. | | | | 2. A RISER DIAGRAM WILL BE REQUIRED FOR THE DRINKING | | FOUNTAIN PIPEING | | FBC BUILDING 2007 106.3.5 MINIMUM PLAN REVIEW CRITERIA | | FOR BUILDINGS. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
7 |
Status |
|
Date |
2011-01-19 |
|
|
Cont ID |
|
Sent By |
ajones |
Date |
2011-01-19 |
Time |
17:13 |
Rev Time |
0.00 |
Received By |
ajones |
Date |
2011-01-19 |
Time |
17:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
6 |
Status |
P |
Date |
2011-01-19 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2011-01-19 |
Time |
10:46 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2011-01-19 |
Time |
10:46 |
Sent To |
|
|
Notes |
2011-01-19 11:47:26 | OK PER CHARLES WU |
|
|
Review Stop |
Z |
ZONING |
Rev No |
5 |
Status |
F |
Date |
2010-12-30 |
|
|
Cont ID |
|
Sent By |
lfranco |
Date |
2010-12-30 |
Time |
11:50 |
Rev Time |
0.00 |
Received By |
lfranco |
Date |
2010-12-30 |
Time |
11:50 |
Sent To |
HIST |
|
Notes |
2010-12-30 11:52:48 | PLANNING AND ZONING: **** FAILED **** | | | | 1. RESPOND TO COMMENTS IN WRITING. | | | | 2. PROVIDE TWO (2) COPIES OF A CURRENT SURVEY, WHICH | | INCLUDES THE PROPERTY'S ADDRESS AND LEGAL DESCRIPTION. | | SHOW ALL DIMENSIONS AND SETBACKS FROM ALL PROPERTY | | LINES TO THE RAMP. | | | | 3. PURSUANT TO SECTION SEC. 94-74(3) OF THE ZONING AND | | LAND DEVELOPMENT REGULATIONS ("ZLDR"), THE MINIMUM | | SETBACKS FOR PRINCIPAL BUILDING IN A SINGLE-FAMILY HIGH | | DENSITY ("SF14") RESIDENTIAL DISTRICT IS AS FOLLOWS: | | | | A. FRONT: 25 FEET; | | B. CORNER: 12.5 FEET; | | C. REAR: 15 FEET OR TEN PERCENT OF LOT DEPTH, WHICHEVER | | IS LESS; | | D. SIDE: FIVE FEET MINIMUM, 15 FEET TOTAL | | | | 4. THIS PERMIT NEEDS HISTORIC REVIEW AND APPROVAL, | | PRIOR TO ZONING SIGN-OFF. | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT ME. | | | | LINDA MIA FRANCO | | SENIOR PLANNER | | PLANNING AND ZONING DEPARTMENT | | TEL: (561) 822-1443 | | EMAIL: [email protected] | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
P |
Date |
2010-08-20 |
|
|
Cont ID |
|
Sent By |
lfranco |
Date |
2010-08-20 |
Time |
20:34 |
Rev Time |
0.00 |
Received By |
lfranco |
Date |
2010-08-11 |
Time |
10:56 |
Sent To |
HIST |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2010-06-17 |
|
|
Cont ID |
|
Sent By |
ajones |
Date |
2010-06-17 |
Time |
17:31 |
Rev Time |
0.00 |
Received By |
ajones |
Date |
2010-06-15 |
Time |
15:29 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2010-04-21 |
|
|
Cont ID |
|
Sent By |
lfranco |
Date |
2010-04-21 |
Time |
15:20 |
Rev Time |
0.50 |
Received By |
lfranco |
Date |
2010-04-21 |
Time |
15:20 |
Sent To |
B |
|
Notes |
2010-04-21 15:27:08 | PLANNING AND ZONING: **** FAILED **** | | | | 1. RESPOND TO COMMENTS IN WRITING. | | | | 2. SHEET 1 DOES NOT SHOW PROPERTY LINES OR DIMENSIONS | | AND SETBACKS FROM ALL PROPERTY LINES, REVISE | | ACCORDINGLY. | | | | 3. PURSUANT TO SECTION SEC. 94-74(3) OF THE ZONING AND | | LAND DEVELOPMENT REGULATIONS ("ZLDR"), THE MINIMUM | | SETBACKS FOR PRINCIPAL BUILDING IN A SINGLE-FAMILY HIGH | | DENSITY ("SF14") RESIDENTIAL DISTRICT IS AS FOLLOWS: | | | | A. FRONT: 25 FEET; | | B. CORNER: 12.5 FEET; | | C. REAR: 15 FEET OR TEN PERCENT OF LOT DEPTH, WHICHEVER | | IS LESS; | | D. SIDE: FIVE FEET MINIMUM, 15 FEET TOTAL | | | | 4. PRIOR TO ZONING SIGN-OFF, APPROVAL FROM THE HISTORIC | | DIVISION SHALL BE OBTAINED FOR SCOPE OF WORK. | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT ME. | | | | LINDA MIA FRANCO | | SENIOR PLANNER | | PLANNING AND ZONING DEPARTMENT | | TEL: (561) 822-1443 | | EMAIL: [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2010-04-05 |
|
|
Cont ID |
|
Sent By |
lfranco |
Date |
2010-04-05 |
Time |
18:13 |
Rev Time |
0.00 |
Received By |
lfranco |
Date |
2010-04-05 |
Time |
18:13 |
Sent To |
I |
|
Notes |
2010-04-05 18:20:50 | PLANNING AND ZONING: **** FAILED **** | | | | 1. RESPOND TO COMMENTS IN WRITING. | | | | 2. PROVIDE TWO (2) COPIES OF A CURRENT SURVEY, WHICH | | INCLUDES THE PROPERTY'S ADDRESS AND LEGAL DESCRIPTION. | | SHOW ALL DIMENSIONS AND SETBACKS FROM ALL PROPERTY | | LINES. | | | | 3. PURSUANT TO SECTION SEC. 94-74(3) OF THE ZONING AND | | LAND DEVELOPMENT REGULATIONS ("ZLDR"), THE MINIMUM | | SETBACKS FOR PRINCIPAL BUILDING IN A SINGLE-FAMILY HIGH | | DENSITY ("SF14") RESIDENTIAL DISTRICT IS AS FOLLOWS: | | | | A. FRONT: 25 FEET; | | B. CORNER: 12.5 FEET; | | C. REAR: 15 FEET OR TEN PERCENT OF LOT DEPTH, WHICHEVER | | IS LESS; | | D. SIDE: FIVE FEET MINIMUM, 15 FEET TOTAL | | | | 4. IS THE SCOPE OF WORK ENCLOSING AN AREA WHERE | | EXISTING COLUMNS ARE? THE PERMIT AND PLANS ARE NOT | | CLEAR. | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT ME. | | | | LINDA MIA FRANCO | | SENIOR PLANNER | | PLANNING AND ZONING DEPARTMENT | | TEL: (561) 822-1443 | | EMAIL: [email protected] | | | | |
|
|