Plan Review Stops For Permit 10030438 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2010-06-15 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2010-06-15 |
Time |
11:48 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2010-06-15 |
Time |
11:48 |
Sent To |
|
|
Notes |
2010-06-15 11:49:44 | PROVISO - PRODUCT APPROVAL (REVIEWED BY D.O.R.) | | REQUIRED FOR DOORS AND LOUVER | | REVISION REQUIRED | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2010-04-28 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2010-04-28 |
Time |
10:12 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2010-04-26 |
Time |
08:46 |
Sent To |
|
|
Notes |
2010-04-28 10:45:26 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBC FLORIDA BUILDING CODE 2007 | | FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING | | CODE | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2007 | | FAC FLORIDA ADMINISTRATIVE CODE | | FS FLORIDA STATUTE | | | | 1. PLEASE SHOW ALL FIRE RATED WALLS ON THE PLAN. SOME | | DETAILS (SUCH AS WALL SECTIONS ON SHEET A1.2) REFER TO | | FIRE RATING BUT NONE SHOWN. FBC EB603.1, FBC508.3.3. | | PLEASE ALSO CLARIFY WHICH OPENINGS AND PENETRATIONS ARE | | TO BE PROTECTED FBC712, FBC715. | | | | 2. FBC1014.2, SEVERAL ROOMS (SUCH AS 2-112, 2-113, | | 2-114, 2-115, 2-002, 2-100, ETC.) WHICH PREVIOUSLY | | EXITED DIRECTLY TO THE OUTSIDE NOW EXITS THROUGH WHAT | | APPEARS TO BE A COURTYARD. NO INFORMATION WAS PROVIDED | | REGARDING THE NEW EXIT PATH. SEE ALSO FBC1026.4.1, | | EMERGENCY ESCAPE AND RESCUE FOR CLASSROOMS IF THE NEW | | EXIT IS NOT DIRECTLY TO THE OUTSIDE. PLEASE REVISE PLAN | | TO SHOW COMPLIANCE FOR NEW MEANS OF EGRESS. | | | | OTHER ROOMS WHICH PREVIOUSLY EXITED TO THE SOUTH NOW | | EXIT TO THE EAST. EXIT DOORS PARTIALLY BLOCK THE | | SIDEWALK, AND APPEAR TO DISCHARGE THROUGH THE STAIRS | | SHOWN AT THE SOUTHEAST CORNER. CAPACITY OF THE STAIR IS | | NOT CLEAR. LIFE SAFETY PLAN SHOULD SHOW EXITING TO THE | | PUBLIC WAY AS IT APPEARS THAT OTHER MEANS OF EGRESS | | COMPONENTS ARE AFFECTED OR BEING UTILIZED. | | | | 3. IT IS NOT CLEAR WHICH WALLS ARE EXTERIOR WALLS. SEE | | FBC704. FOR INSTANCE, NE PORTION OF PLAN SHOWS TWO | | DOUBLE DOORS. IS THERE A ROOF OVER THIS AREA, WITH | | WALLS, SO THIS AREA IS INTERIOR? PLEASE CLARIFY | | CONIDITIONS THROUGH WHICH EXITING IS NOW REQUIRED BY | | NEW LIFE SAFETY PLAN. FBC 1002. | | | | 4. FBC3105.1.1.1, 7'6" MINIMUM REQUIRED FOR CANOPY, 7' | | SHOWN, DETAIL 08-A1.3. | | | | 5. FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED FOR | | NEW DOORS, WINDOWS, LOUVERS FAC9B72. | | | | 6. NEW WINDOWS ARE SHOWN AT THE STAIR. IS THIS A RATED | | STAIR? SEE FBC1023, FBC1020 AND SHOW COMPLIANCE ON THE | | PLAN. IT IS NOT CLEAR HOW THE PROPOSED IMPROVEMENT WILL | | | | 7. PLEASE PROVIDE A COPY OF THE CONTRACT FOR THIS JOB. | | | | 8. A COPY OF THE SOILS INVESTIGATION REPORT WILL BE | | REQUIRED PRIOR TO FOUNDATION WORK, FBC1802.2.1 (PROVISO | | ITEM). | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2010-08-09 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2010-08-09 |
Time |
09:42 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2010-08-09 |
Time |
09:42 |
Sent To |
|
|
Notes |
2010-08-09 09:43:48 | REVIEW COMPLETED BY CONTRACT WORK JOHN DICKINSON | | ENTERED BY J WITMER |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2010-06-15 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2010-06-15 |
Time |
16:07 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2010-06-15 |
Time |
15:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2010-04-14 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2010-04-14 |
Time |
15:24 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2010-04-14 |
Time |
13:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2010-06-10 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2010-06-10 |
Time |
16:19 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2010-06-10 |
Time |
14:54 |
Sent To |
|
|
Notes |
2010-06-10 16:19:26 | *****APPROVED***** | | | | | | THE COMMENT FROM THE PREVIOUS FIRE PLAN REVIEW HAS BENN | | ADDRESSED; PLAN SHEETS LS1.01, LS1.02, LS1.1, A6.1, | | FP-1, FP-2, E-03, AND E-05 WERE STAMPED, INITIALED, AND | | DATED |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2010-04-18 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2010-04-18 |
Time |
13:41 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2010-04-12 |
Time |
15:40 |
Sent To |
|
|
Notes |
2010-04-12 16:06:29 | *****FIRE-STAMPING NEEDED***** | | | | | | THE APPROPIATE PLAN SHEETS TO BE FIRE-STAMPED WHEN THE | | OTHERS PLAN EXAMINERS' COMMENTS AS WELL AS THE | | FOLLOWING HAS BEEN ADDRESSED: | | | | 1. DOOR SCHEDULE DOES NOT INDICATE WHICH DOORS ARE | | FIRE-RATED AND/OR DURATION OF THE FIRE-RATING. | | | | MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2010-05-24 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2010-05-24 |
Time |
08:36 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2010-05-24 |
Time |
08:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2010-04-28 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2010-04-28 |
Time |
10:50 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2010-03-18 |
Time |
11:12 |
Sent To |
|
|
Notes |
2010-03-18 11:14:49 | INCOMING SENT TO C-37 |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
N |
Date |
2010-04-26 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2010-04-26 |
Time |
10:15 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2010-04-26 |
Time |
10:15 |
Sent To |
|
|
Notes |
2010-04-26 10:15:54 | INTERIOR RENOVATION | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2010-07-29 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2010-07-29 |
Time |
10:43 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2010-07-29 |
Time |
10:43 |
Sent To |
|
|
Notes |
2010-07-29 10:44:00 | PROVISO ADDRESSED WITH REVISION #10070040 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2010-06-15 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2010-06-15 |
Time |
17:18 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2010-06-15 |
Time |
17:18 |
Sent To |
|
|
Notes |
2010-06-15 17:19:28 | **PROVISO** | | | | REVISE PLANS TO SHOW PROPER OCCUPANCY CLASSIFICATIONS | | AND VENTILATION RATES PER FBC-M 403.4. | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | RONALD J. REGUEIRO | | 561.805.6719 | | [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2010-04-07 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2010-04-07 |
Time |
16:08 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2010-04-07 |
Time |
16:08 |
Sent To |
|
|
Notes |
2010-04-07 16:09:53 | REVIEW #: 1ST | | ACTION: DENIED | | | | FBC 2007 CODE FAMILY W/ 2009 SUPPLEMENTS | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | 1. P001 SHOWS CONDENSATE TO DRYWELL OR STORM DRAIN, | | P101 AND PLAN NOTE 1 ON M02 SHOW CONDENSATE TO HUB | | DRAIN. CONDENSATE CANNOT DISCHARGE TO SANITARY SEWER | | PER MUNICIPAL CODE, FBC M 307.2.1. | | | | 2. LOCATION OF FIRE RATED WALLS NOT CLEAR. PROVIDE | | LOCATION OF ALL FIRE RATED WALLS FBC M 607.8. | | | | 3. GENERAL NOTE 13 ON M01 CALLS FOR AN INSTALLATION | | DETAIL FOR EXTERIOR EQUIPMENT TO BE PREPARED BY | | STRUCTURAL SPECIALTY ENGINEER, FBC M301.12. DETAIL WAS | | NOT PROVIDED ON STRUCTURAL SHEETS. | | | | 4. QUANTITIES ON AIR BALANCE SCHEDULES DO NOT MATCH THE | | QUANTITIES ON THE FLOOR PLAN. SHOW QUANTITIES IN | | COMPLIANCE WITH FBC M403.4. | | | | 5. SOME OUTDOOR AIR QUANTITIES SHOWN ON THE SCHEDULE DO | | NOT APPEAR TO MEET THE REQUIREMENTS OF ASHRAE62, FBC | | M403.4. FOR EXAMPLE, AHU5 STATES THAT 260CFM OF OUTSIDE | | AIR IS PROVIDED. SEE TABLE 6-1, EDUCATIONAL FACILITIES | | MEDIA CENTER, 429 CFM REQUIRED. | | | | 6. PRODUCT APPROVAL APPROVED BY DESIGNER OF RECORD | | REQUIRED FOR LOUVERS, FAC RULE 9B-72. | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | RONALD J. REGUEIRO | | 561.805.6719 | | [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2010-04-12 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2010-04-12 |
Time |
09:53 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2010-04-08 |
Time |
10:38 |
Sent To |
|
|
Notes |
2010-04-08 11:09:51 | NOTE: THE DRY VENT BETWEEN WATER CLOSETS IN ROOMS | | 2-204 & 2-203 IS REQUIRED. SEE HIGHLIGHTED AREA ON | | P-201 | | 911.2 VENT CONNECTION. | | THE CIRCUIT VENT CONNECTION SHALL BE LOCATED BETWEEN | | THE TWO MOST UPSTREAM FIXTURE DRAINS. THE VENT SHALL | | CONNECT TO THE HORIZONTAL BRANCH AND SHALL BE INSTALLED | | IN ACCORDANCE WITH SECTION 905. THE CIRCUIT VENT PIPE | | SHALL NOT RECEIVE THE DISCHARGE OF ANY SOIL OR WASTE. | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
N |
Date |
2010-08-30 |
|
|
Cont ID |
|
Sent By |
kdfreema |
Date |
2010-08-30 |
Time |
11:15 |
Rev Time |
0.00 |
Received By |
kdfreema |
Date |
2010-08-30 |
Time |
11:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
2010-03-22 |
|
|
Cont ID |
|
Sent By |
kdfreema |
Date |
2010-03-22 |
Time |
10:47 |
Rev Time |
0.00 |
Received By |
kdfreema |
Date |
2010-03-22 |
Time |
10:46 |
Sent To |
|
|
Notes |
|
|