Plan Review Details - Permit 10030408
Plan Review Stops For Permit 10030408 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2010-03-25 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2010-03-25 |
Time |
16:24 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2010-03-25 |
Time |
16:24 |
Sent To |
|
|
Notes |
2010-03-25 16:53:02 | REVISIONS REQUIRED | | | | 1) THE PRODUCT APPROVAL FOR THE BILCO ROOF HATCH HAS | | MAXIMUM DESIGN PRESSURES OF + OR - 70 PSF. THE ROOF | | PLANS SHOWS THE NEW LOCATION OF THE HATCH IN CORNER | | ROOF ZONE 3. THIS ROOF HATCH WILL NEED TO BE LOCATED IN | | ROOF ZONE 1 WHICH HAS AN UPLIFT PRESSURE OF - 46.7 PSF | | PER DRAWING S-2 OF THE PLANS. PLEASE CORRECT. | | | | 2) STEEL DECK SYSTEM LIMITATION NUMBER 1 ON PAGE 27 OF | | THE PRODUCT APPROVAL REQUIRES FIELD WITHDRAWL | | RESISTANCE TESTING IN COMPLIANCE WITH TAS 105. RAS 117 | | CALCULATIONS ARE BASED ON A FASTENER RESISTANCE OF | | -250.469 LBF. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2010-03-18 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2010-03-18 |
Time |
08:33 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2010-03-18 |
Time |
07:14 |
Sent To |
|
|
Notes |
2010-03-18 08:33:13 | 2007 FBC W/2009 REVISIONS | | COMMERCIAL RE-ROOF | | | | DENIED BY BUILDING | | | | 1) SUBMIT TWO CURRENT COPIES OF PRODUCT APPROVALS FOR | | THE SARNAFIL ROOFING MEMBRANE. THE ONES THAT WERE | | SUBMITTED EXPIRED ON 7/5/2006. THE CURRENT ONE IS NOA | | NO 08-0717.09. | | | | 2) SPECIFY THE APPROVED ASSEMBLY FROM THE NOA THAT WILL | | BE INSTALLED. SPECIFY THE INSULATION, FASTENER DENSITY | | AND MAXIMUM DESIGN DESIGN PRESSURE FOR THE ASSEMBLY. IF | | INCREASED FASTENER DENSITY IS REQUIRED TO RESIST ROOF | | UPLIFT PRESSURES IN ROOF ZONES 2 AND 3, SUBMIT TWO SETS | | OF RAS 117 CALCULATIONS FROM A FLORIDA REGISTERED | | ENGINEER OR ARCHITECT. SEE STEEL DECK SYSTEM AND | | GENERAL LIMITATIONS AT THE END OF THE NOA. | | | | 3) SUBMIT TWO CURRENT COPIES OF PRODUCT APPROVALS FOR | | THE NEW BILCO ROOF HATCH THAT WILL BE INSTALLED. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2010-03-24 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2010-03-24 |
Time |
15:39 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2010-03-24 |
Time |
15:39 |
Sent To |
|
|
Notes |
2010-03-24 15:40:57 | *******************EXPEDITED ********************* | | 2ND RUN | 2010-03-24 15:40:15 | GAVE TO ROBBIE |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2010-03-18 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2010-03-18 |
Time |
08:33 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2010-03-17 |
Time |
16:37 |
Sent To |
|
|
Notes |
2010-03-17 16:39:05 | *******************EXPEDITED******************* | | GAVE TO ROBBIE |
|
|
|