Plan Review Stops For Permit 10020360 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2010-03-01 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2010-03-01 |
Time |
10:35 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2010-03-01 |
Time |
10:04 |
Sent To |
|
|
Notes |
2010-03-01 10:35:28 | DENIED BY BUILDING | | | | 1) THE CONTRACTOR WILL NEED TO BE SPECIFIED BEFORE THE | | PERMIT CAN BE ISSUED. | | | | 2) THE VALUE OF THE WORK SPECIFIED IS TOO LOW. PLEASE | | INDICATE THE CORRECT VALUE. | | | | 3) THE PLAN REVIEW FEES HAVE NOT BEEN PAID. | | | | 4) FBC 11-4.7.7 REQUIRES CURB RAMPS TO HAVE DETECTABLE | | WARNINGS EXTENDING THE FULL WIDTH AND DEPTH OF THE CURB | | RAMP. SHOW COMPLIANCE. SEE MARK-UP ON SHEET A1-1.2. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2010-02-23 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2010-02-23 |
Time |
11:23 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2010-02-23 |
Time |
11:20 |
Sent To |
|
|
Notes |
2010-02-23 11:22:36 | ALL ELEVATOR DISCONNECTS HAVE INCORRECT OVER CURRENT | | PROTECTION. MAXIMUM OF 175%. | | | | APPLIED VALUE IS TOO LOW FOR APPLIED SCOPE OF WORK. | | | | CONTRACTOR AS APPLIED IS NOT LICENSED FOR SCOPE OF | | WORK. |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2010-02-24 |
|
|
Cont ID |
|
Sent By |
efabian |
Date |
2010-02-24 |
Time |
15:22 |
Rev Time |
2.00 |
Received By |
efabian |
Date |
2010-02-24 |
Time |
15:22 |
Sent To |
|
|
Notes |
2010-02-24 15:27:36 | 1. MINIMUM CLEARANCE OF 5 FEET BETWEEN PLANTING OF | | TREES AND UTILITIES PIPELINE NOT ACHIEVED AND | | | | 2. SHOW PIPE SEGMENTS IN LINEAR FEET DIMENSIONS BETWEEN | | SEGMENT CONNECTIONS |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2010-03-09 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2010-03-09 |
Time |
10:57 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2010-03-09 |
Time |
10:55 |
Sent To |
|
|
Notes |
2010-03-09 10:57:44 | DIGITAL PLAN REVIEW TEST | | CITY CENTER | | | | 1. INCREASE DOOR WIDTH AS PER NFPA 101, SECTION 7.2.1. | | | | 2. FIRE HOSE VALVE APPEARS TO BE LOCATED IN TRAVEL PATH | | OF STAIRS. PLEASE SEE NFPA 14, THE STANDARD OF | | STANDPIPE SYSTEMS. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
|
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
|
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2010-02-23 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2010-02-23 |
Time |
08:21 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2010-02-23 |
Time |
08:14 |
Sent To |
|
|
Notes |
2010-02-23 08:21:55 | REVIEW #: 1ST - DIGITAL PLANS | | ACTION: DENIED | | | | FBC 2007 CODE FAMILY W/ 2009 SUPPLEMENTS | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | 1. PAGE M1-1.2: FIRE DAMPER IS REQUIRED IN THE 10X10 | | SUPP;Y DUCT PENETRATING MEZZANINE LEVEL WALL IN | | ACCORDANCE WITH FBC-M 607.5.3. | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | RONALD J. REGUEIRO | | 561.805.6719 | | [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2010-03-23 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2010-03-23 |
Time |
10:15 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2010-03-23 |
Time |
10:15 |
Sent To |
|
|
Notes |
2010-03-23 10:21:35 | WATER PIPE FOR TOILET ROOMS #105 & 106 IS REQUIRED TO | | BE 2" FBC PLUMBING 2007 TABLE 603.1 | | | | REVIEW BY LARRY WAGNER | | CHIEF PLUMBING INSPECTOR | | (561) 805-6692 | | FAX (561) 653-2692 | | E-MAIL [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2010-03-18 |
|
|
Cont ID |
|
Sent By |
kdfreema |
Date |
2010-03-18 |
Time |
09:40 |
Rev Time |
0.00 |
Received By |
kdfreema |
Date |
2010-03-18 |
Time |
09:40 |
Sent To |
|
|
Notes |
2010-03-18 09:46:07 | ***PROVISO*** | | | | PLEASE ENSURE THAT ALL PLANS ARE FOLLOWED DURING | | CONSTRUCTION. ANY CHANGED WILL NEED TO BE RESUBMITTED | | FOR REVIEW. |
|
|