Plan Review Details - Permit 10020267
Plan Review Stops For Permit 10020267
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2010-03-01 Cont ID  
Sent By shill Date 2010-03-01 Time 15:17 Rev Time 0.00
Received By shill Date 2010-03-01 Time 15:17 Sent To  
Notes
2010-03-01 15:20:01****PROVISO****
 ****REVISION REQUIRED - REVISE INSTALLATION SCHEDULE OR
 REMOVE OPENING #5 FROM SCOPE****
 ****ISSUED AT CONTRACTOR'S RISK****
  
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2007
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
  
 1. OPENING #5, ANCHOR SPACING FOR BOTTOM TRACK IS 2.49
 ON THE INSTALLATION SCHEDULE PREPARED BY CONTRACTOR,
 BUT THE PRODUCT APPROVAL (PAGE 11) REQUIRES 3" MINIMUM
 ANCHOR SPACING. EITHER REVISE OPENING #5 TO COMPLY WITH
 PRODUCT APPROVAL OR REMOVE FROM SCOPE OF WORK.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2010-02-11 Cont ID  
Sent By shill Date 2010-02-11 Time 13:55 Rev Time 0.00
Received By shill Date 2010-02-11 Time 13:55 Sent To  
Notes
2010-02-11 14:09:13****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2007
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
  
 1. HOW HAS IT BEEN DETERMINED THAT THE SUBSTRATE IS
 CONCRETE (AND NOT A BOND BEAM, WHICH WOULD REQUIRE USE
 OF A DETAIL WITH CONCRETE BLOCK SUBSTRATE)?
  
 2. SEE OPENING 5, 3" SPACING SPECIFIED, 3" EDGE
 DISTANCE. THE CHART STATES THAT .83 FACTOR WAS USED BUT
 THAT WAS NOT APPLIED, SEE SHEET 10. PLEASE REVISE
 INSTALLATION SCHEDULE TO COMPLY WITH PRODUCT APPROVAL.
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2010-03-15 Cont ID  
Sent By jgomez Date 2010-03-15 Time 10:48 Rev Time 0.00
Received By jgomez Date 2010-03-15 Time 10:48 Sent To  
Notes
2010-03-15 10:49:15SENT TO S. HILL'S DESK.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2010-02-23 Cont ID  
Sent By btrobaug Date 2010-02-23 Time 08:47 Rev Time 0.00
Received By btrobaug Date 2010-02-23 Time 08:47 Sent To B
Notes
2010-02-23 08:48:14TO SAMANTHA./WRT.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2010-02-11 Cont ID  
Sent By shill Date 2010-02-11 Time 13:55 Rev Time 0.00
Received By shill Date 2010-02-11 Time 08:29 Sent To  
Notes
2010-02-11 08:30:13SENT TO MISC 1.