Plan Review Stops For Permit 10020191 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2010-02-25 |
|
|
Cont ID |
|
Sent By |
lfranco |
Date |
2010-03-10 |
Time |
13:08 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2010-02-25 |
Time |
16:24 |
Sent To |
|
|
Notes |
2010-02-25 16:27:10 | BUILDING PROVISO | | | | THE EXISTING FENCE IS REQUIRED TO COMPLY WITH BARRIER | | REQUIREMENTS OF FBC R4101.17. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2010-03-10 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2010-03-10 |
Time |
14:56 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2010-03-10 |
Time |
14:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2010-02-25 |
|
|
Cont ID |
|
Sent By |
lfranco |
Date |
2010-02-24 |
Time |
16:18 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2010-02-25 |
Time |
15:36 |
Sent To |
|
|
Notes |
2010-02-25 16:22:01 | 2007 FBC W/2007 REVISIONS | | 2008 NEC | | | | DENIED BY ELECTRIC | | | | 1) SUBMIT MANUFACTURER'S SPECS. FOR THE ELECTRIC HEAT | | PUMP THAT WILL BE INSTALLED. | | | | 2) SIGNED AND SEALED PLANS ARE NOT PERMITTED TO BE | | REVISED BY USING WHITE-OUT. FS 471 | | | | 3) VALUE OF THE WORK IS TOO LOW. THE VALUE HAS BEEN | | ADJUSTED TO $20,000.00 BASED ON MARSHALL AND SWIFT | | ESTIMATES. ADDITIONAL PERMIT FEES ARE DUE. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2010-02-25 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2010-02-25 |
Time |
15:44 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2010-02-25 |
Time |
15:37 |
Sent To |
|
|
Notes |
2010-02-25 16:23:37 | NO GAS APPLIANCES SHOWN ON PLANS. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2010-03-09 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2010-03-09 |
Time |
11:20 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2010-03-09 |
Time |
11:20 |
Sent To |
Z |
|
Notes |
2010-03-09 11:22:11 | ZONING IN BOX./WRT |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2010-02-25 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2010-02-25 |
Time |
16:29 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2010-02-09 |
Time |
10:42 |
Sent To |
|
|
Notes |
2010-02-10 07:15:02 | SENT TO ZONING. | 2010-02-09 10:43:05 | TO SWIMING POOL IN BOX./WRT. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2010-02-25 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2010-02-25 |
Time |
16:23 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2010-02-25 |
Time |
16:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2010-03-10 |
|
|
Cont ID |
|
Sent By |
lfranco |
Date |
2010-03-10 |
Time |
11:24 |
Rev Time |
0.00 |
Received By |
lfranco |
Date |
2010-03-10 |
Time |
11:24 |
Sent To |
B |
|
Notes |
2010-03-10 13:10:24 | PLANNING AND ZONING: **** PASSED WITH PROVISO, THE | | EXISTING GATE SHALL BE REPLACED OR RETROFITTED TO HAVE | | A SELF-CLOSING AND SELF-LATCHING GATE **** | | | | | | | | PURSUANT TO THE CITY OF WEST PALM BEACH ZONING AND LAND | | DEVELOPMENT REGULATIONS, SECTION, 94-304(D)(2)(B) AND | | (C): | | B. EVERY SWIMMING POOL SHALL BE ENCLOSED BY A FENCE OR | | SIMILAR STRUCTURE WHICH IS INSTALLED TO OBSTRUCT ACCESS | | BY PERSONS OTHER THAN THE OWNERS OR OCCUPANTS OF THE | | RESIDENCE WITHIN WHICH A SWIMMING POOL IS LOCATED. | | BARRIERS OR FENCES SHALL BE AT LEAST FOUR FEET IN | | HEIGHT ABOVE GRADE. | | C. ACCESS TO AN ACCESSORY SWIMMING POOL MUST BE THROUGH | | A BUILDING OR THROUGH A SELF-CLOSING AND SELF-LATCHING | | GATE OR THROUGH A SCREEN ENCLOSURE DOOR WITH LATCHES | | PLACED AT LEAST 54 INCHES ABOVE BOTTOM OF GATE. AT | | LEAST 90 PERCENT OF THE SURFACE AREA OF ALL SCREEN | | ENCLOSURES SHALL BE SCREENING MATERIAL THROUGH WHICH | | AIR SHALL FLOW. ALL POOLS LOCATED ON A CORNER LOT SHALL | | BE SCREENED AT THE CORNER LOT LINE BY AT LEAST A | | 42-INCH HIGH LANDSCAPE BUFFER, AS MEASURED FROM GRADE, | | AT THE PROPERTY LINE, TO ENSURE PRIVACY. | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT ME. | | | | LINDA MIA FRANCO | | SENIOR PLANNER | | PLANNING AND ZONING DEPARTMENT | | TEL: (561) 822-1443 | | EMAIL: [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2010-02-24 |
|
|
Cont ID |
|
Sent By |
lfranco |
Date |
2010-02-24 |
Time |
15:41 |
Rev Time |
0.00 |
Received By |
lfranco |
Date |
2010-02-24 |
Time |
15:41 |
Sent To |
B |
|
Notes |
2010-02-24 16:17:54 | PLANNING AND ZONING: **** FAILED **** | | | | 1. RESPOND TO COMMENTS IN WRITING. | | | | 2. AS THE SURVEY DOES NOT SHOW AN EXISTING PERMANENT | | FENCE COMPLETELY SURROUNDING THE POOL, A FENCE PERMIT | | SHALL BE SUBMITTED CONCURRENTLY AND SHALL CONFORM TO | | THE MINIMUM STANDARDS PROVIDED BELOW: | | | | PURSUANT TO THE CITY OF WEST PALM BEACH ZONING AND LAND | | DEVELOPMENT REGULATIONS, SECTION, 94-304(D)(2)(B) AND | | (C): | | B. EVERY SWIMMING POOL SHALL BE ENCLOSED BY A FENCE OR | | SIMILAR STRUCTURE WHICH IS INSTALLED TO OBSTRUCT ACCESS | | BY PERSONS OTHER THAN THE OWNERS OR OCCUPANTS OF THE | | RESIDENCE WITHIN WHICH A SWIMMING POOL IS LOCATED. | | BARRIERS OR FENCES SHALL BE AT LEAST FOUR FEET IN | | HEIGHT ABOVE GRADE. | | C. ACCESS TO AN ACCESSORY SWIMMING POOL MUST BE THROUGH | | A BUILDING OR THROUGH A SELF-CLOSING AND SELF-LATCHING | | GATE OR THROUGH A SCREEN ENCLOSURE DOOR WITH LATCHES | | PLACED AT LEAST 54 INCHES ABOVE BOTTOM OF GATE. AT | | LEAST 90 PERCENT OF THE SURFACE AREA OF ALL SCREEN | | ENCLOSURES SHALL BE SCREENING MATERIAL THROUGH WHICH | | AIR SHALL FLOW. ALL POOLS LOCATED ON A CORNER LOT SHALL | | BE SCREENED AT THE CORNER LOT LINE BY AT LEAST A | | 42-INCH HIGH LANDSCAPE BUFFER, AS MEASURED FROM GRADE, | | AT THE PROPERTY LINE, TO ENSURE PRIVACY. | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT ME. | | | | LINDA MIA FRANCO | | SENIOR PLANNER | | PLANNING AND ZONING DEPARTMENT | | TEL: (561) 822-1443 | | EMAIL: [email protected] | | |
|
|