Plan Review Details - Permit 10010378
Plan Review Stops For Permit 10010378 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2010-04-05 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2010-03-31 |
Time |
16:27 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2010-03-31 |
Time |
16:27 |
Sent To |
|
|
Notes |
2010-03-31 16:27:45 | ****PROVISO**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBC FLORIDA BUILDING CODE 2007 | | FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING | | CODE | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2007 | | FAC FLORIDA ADMINISTRATIVE CODE | | FS FLORIDA STATUTE | | | | 1. DESIGN PRESSURES ARE TOO LOW. SEE FBC R TABLE | | 301.2(2) AND FBC R TABLE 301.2(3). BASED ON OPENING | | SIZE, IF OPENING 8 IS IN ZONE 5, 15' BUILDING HEIGHT, | | BETWEEN 20 AND 50SF, -53.24 MINIMUM DESIGN PRESSURE | | REQUIRED. PLEASE PROVIDE BUILDING HEIGHT SO MINIMUM | | DESIGN PRESSURE REQUIREMENTS CAN BE DETERMINED. PLEASE | | CONTACT ME IF YOU NEED ASSISTANCE. | | | | PROVIDE REVISED INSTALLATION SCHEDULE FOR EXPOSURE C AT | | INSPECTION | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2010-03-08 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2010-03-08 |
Time |
17:38 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2010-03-08 |
Time |
17:38 |
Sent To |
|
|
Notes |
2010-03-08 17:44:06 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBC FLORIDA BUILDING CODE 2007 | | FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING | | CODE | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2007 | | FAC FLORIDA ADMINISTRATIVE CODE | | FS FLORIDA STATUTE | | | | 1. DESIGN PRESSURES ARE TOO LOW. SEE FBC R TABLE | | 301.2(2) AND FBC R TABLE 301.2(3). BASED ON OPENING | | SIZE, IF OPENING 8 IS IN ZONE 5, 15' BUILDING HEIGHT, | | BETWEEN 20 AND 50SF, -53.24 MINIMUM DESIGN PRESSURE | | REQUIRED. PLEASE PROVIDE BUILDING HEIGHT SO MINIMUM | | DESIGN PRESSURE REQUIREMENTS CAN BE DETERMINED. PLEASE | | CONTACT ME IF YOU NEED ASSISTANCE. | | | | 2. SHUTTER CONNECTION MOUNTING TYPE SHOULD CORRELATE | | WITH ANCHOR CHARTS, SEE SHEET 8; FOR INSTANCE, WALL | | MOUNT 1, CEILING MOUNT 2, ETC. | | | | 3. 10" SPACING DOES NOT COMPLY, SEE OPENING 8; THIS | | ANCHOR CANNOT BE USED FOR THIS SPAN AND DEISGN | | PRESSURE, CONCRETE BLOCK SUBSTRATE. | | | | 4. ONLY OPENINGS 8-10 ARE ON THE INSTALLATION SCHEDULE. | | IT APPEARS THAT A SHEET IS MISSING. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2010-02-03 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2010-02-03 |
Time |
16:28 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2010-02-03 |
Time |
16:28 |
Sent To |
|
|
Notes |
2010-02-03 16:29:36 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2007 | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | 1. COMPLETE THE SAMPLE INSTALLATION SCHEDULE OR PROVIDE | | ALL INFORMATION TO SHOW CODE COMPLIANCE IN ANOTHER | | FORMAT, FBC*106, FBC R301, FBC1609. TWO SETS REQUIRED. | | THIS FORM IS AVAILABLE IN THE LOBBY OR ON THE INTERNET | | AT | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_ | | INSTALLATION.PDF | | | | 2. PROVIDE A FLOOR PLAN SHOWING WHERE THE SHUTTERS WILL | | BE INSTALLED AND PANEL SIZES WHICH CORRELATES WITH THE | | INSTALLATION SCHEDULE, ITEM 2 ABOVE. FBC R301, FBC1609, | | FBC*106. | | | | 3. SHOW THE EMERGENCY MEANS OF ESCAPE, FBC R310.4. | | | | 4. REVISE EXPOSURE CATEGORY OR EXPLAIN RATIONALE FOR | | EXPOSURE B. FBC1609, FBC R301.2.1.4. NOTE THAT THE CODE | | CHANGED EFFECTIVE MARCH 1, 2009. | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2010-03-24 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2010-03-23 |
Time |
16:18 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2010-03-23 |
Time |
16:16 |
Sent To |
|
|
Notes |
2010-03-24 16:19:02 | GAVE TO SAMANTHA |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2010-03-03 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2010-03-03 |
Time |
10:22 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2010-03-03 10:22:43 | SENT TO S HILL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2010-02-03 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2010-02-03 |
Time |
16:29 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2010-01-21 |
Time |
10:44 |
Sent To |
|
|
Notes |
2010-01-25 10:48:33 | GAVE TO SAMANTA |
|
|
|