Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2010-03-01 Cont ID  
Sent By shill Date 2010-03-01 Time 10:38 Rev Time 0.00
Received By shill Date 2010-03-01 Time 10:38 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2010-01-27 Cont ID  
Sent By shill Date 2010-01-27 Time 11:30 Rev Time 0.00
Received By shill Date 2010-01-27 Time 11:30 Sent To P
Notes
2010-01-27 11:34:21****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2007
 FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2007
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
 1. PROVIDE A PLAN TO SHOW LOCATION OF PARKING,
 ACCESSIBLE PARKING, ACCESSIBLE ENTRANCE, TOTAL NUMBER
 OF PARKING SPACES, NUMBER OF ACCESSIBLE SPACES. SEE
 FBC11-4.1.2(5)(A), FBC11-4.6. PLANS SHOULD SHOW
 COMPLIANCE WITH ALL REQUIREMENTS; LANDSCAPE PLANS ONLY
 WERE PROVIDED.
  
 2. SEPARATE PERMITS WILL BE REQUIRED FOR
 RESURFACE/RESTRIPING, LANDSCAPING, AND IRRIGATION.
 PROVIDE A COPY OF THE CONTRACT FOR THESE ITEMS.
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2010-02-16 Cont ID  
Sent By lmartine Date 2010-02-16 Time 16:28 Rev Time 0.00
Received By lmartine Date 2010-02-16 Time 16:28 Sent To  
Notes
2010-02-16 16:34:12GAVE TO KENNY

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2010-02-16 Cont ID  
Sent By shill Date 2010-02-01 Time 16:28 Rev Time 0.00
Received By lmartine Date 2010-01-19 Time 16:10 Sent To  
Notes
2010-01-20 16:10:33TO ZONING BOX

Review Stop P PLUMBING
Rev No 2 Status P Date 2010-02-23 Cont ID  
Sent By kstevens Date 2010-02-23 Time 09:39 Rev Time 0.00
Received By kstevens Date 2010-02-23 Time 09:39 Sent To Z
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2010-02-01 Cont ID  
Sent By kstevens Date 2010-02-01 Time 16:17 Rev Time 0.00
Received By kstevens Date 2010-02-01 Time 16:17 Sent To  
Notes
2010-02-01 16:35:38DENIED
 REFERENCE:
 FBC-2007 PLUMBING
 FBC-2007 CHAPTER 1
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 1. PLANS PREPARED BY A LICENSED DESIGN PROFESSIONAL,
 (LANDSCAPE ARCHITECT), SHALL BE SIGNED, SEALED AND
 DATED BY THE DESIGN PROFESSIONAL. SECTION 106.1, FAC
 61G1.10 & FS 481.321. PLANS SUBMITTED ARE COPIES OF
 SIGNED/SEALED/DATED PLANS.
  
 2. SHT 2 0F 2 SHOW THE LOCATION OF THE METER, THE
 BACKFLOW, THE CONTROLLER AND THE RAIN SENSOR ON THE
 PLANS. SECTION 106.1.1.
  
 3. A SEPARATE IRRIGATION PERMIT IS REQUIRED. SECTION
 105.1.
  
 4. A SEPARATE BACKFLOW PERMIT IS REQUIRED. BACKFLOW
 SHALL BE INSTALLED BY A LICENSED PLUMBING CONTRACTOR.
 FS 489.105(M) & SECTION 608.13.2/608.13.3.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]
  

Review Stop Z ZONING
Rev No 2 Status P Date 2010-02-24 Cont ID  
Sent By kdfreema Date 2010-02-24 Time 09:22 Rev Time 0.00
Received By kdfreema Date 2010-02-24 Time 09:22 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2010-01-21 Cont ID  
Sent By kdfreema Date 2010-01-21 Time 09:09 Rev Time 0.00
Received By kdfreema Date 2010-01-21 Time 09:09 Sent To  
Notes
2010-01-21 10:50:29***FAILED***
  
 1. TWO SETS OF ORIGINAL SIGNED AND SEALED DOCUMENTS ARE
 REQUIRED TO BE SUBMITTED. COPIES OF SIGNED AND SEALED
 DRAWINGS TO NOT MEET THE REQUIREMENT.
  
 2. PLEASE ADDRESS THE ISSUE OF ACCESSIBLE PARKING. IT
 IS UNDERSTOOD THAT THIS PARKING LOT SERVICES A BUILDING
 ON OTHER SIDE OF 24TH STREET. IS ALL OF THE REQUIRED
 ACCESSIBLE PARKING ON THAT PROPERTY?
  
 3. IF THE TWO FOOT OVERHANG IS USED, THE WHEEL STOPS
 WILL NEED TO BE DELETED AND "D" CURB ADDED AT THE
 AS-SHOWN EDGE OF PAVEMENT.
  
 4. PLEASE CORRECT THE REFERENCES TO THE CITY OF
 GREENACRES UNDER GENERAL NOTES TO READ THE CITY OF WEST
 PALM BEACH.
  
 PLEASE CONTACT KELLY FREEMAN, GIS PLANNER, AT
 561-822-1458 WITH QUESTIONS.
  
  