Plan Review Stops For Permit 10010061 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2010-03-31 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2010-03-31 |
Time |
11:18 |
Rev Time |
0.88 |
Received By |
jwitmer |
Date |
2010-03-31 |
Time |
11:18 |
Sent To |
|
|
Notes |
2010-03-31 11:51:50 | BUILDING PLAN REVIEW | | PERMIT: 10010061 | | ADD: 4335 EASLEY ST | | CONT: MURRY LOGAN | | TEL: (561)686-3948 | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | W/ 2009 FBC SUPPLEMENTS | | * WEST PALM BEACH AMENDMENTS | | | | | | BUILDING APPROVED WITH EXCEPTION! | | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO | | CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO | | INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE | | ASSESSMENT OF RE-INSPECTION FEE(S). | | | | | | | | 1) PLANS INDICATE THE WIND DESIGN CRITERIA: 1603.1.4 | | WIND DESIGN DATA. | | THE FOLLOWING INFORMATION RELATED TO WIND LOADS NEEDS | | TO BE CORRECTED:S | | 1.1. COMPLIED. | | | | 1.2. WIND IMPORTANCE FACTOR, I W , AND BUILDING | | CLASSIFICATION FROM TABLE 1604.5 OR TABLE 6-1, ASCE 7 | | AND BUILDING CLASSIFICATION IN TABLE 1-1, ASCE 7 | | NOTE TABLE 1-1 INDICATES BUILDING CATEGORY III | | BUILDINGS AS PUBLIC UTILITY FACILITIES | | TABLE 6-1 INDICATES CATEGORY III BUILDINGS : 1.15 | | IMPORTANCE FACTOR | | | | 1.3 3. WIND EXPOSURE, IF MORE THAN ONE WIND EXPOSURE IS | | UTILIZED, THE WIND EXPOSURE AND APPLICABLE WIND | | DIRECTION SHALL BE INDICATED. PLEASE BE AWARE THIS AREA | | IS TO BE CONSIDERED A "C" WIND AREA WITH HIGHER WIND | | PRESSURES! FBC 1609.4.3EXPOSURE "C" | | | | 2) SHEET# 9 NOTE# 5 INDICATES THE STAIR GUARD-RAIL NOT | | SHOWN FOR CLARITY, PLEASE PROVIDE COMPLIANCE WITH | | 1013.3 RESPONCE INDICATES SHOP DRAWING TO FOLLOW | | PERMITING, CONTRACTOR AT OWN RISK. COMPLIANCE WITH | | 1013.3 NEVER PROVIDED. SHOP DRAWING WILL BE CONSIDERED | | A REVISION WITH SEPERATE REVIEW AND ASSOCIATED FEES. | | | | JIM WITMER C. B. O. | | COMMERCIAL COMBINATION PLAN REVIEW | | | | TEL: (561)805-6715 | | FAX: (561)805-6731 | | E-MAIL: [email protected] | | | | PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE | | CUSTOMER SERVICE SURVEY AT: | | WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES | | | | CONSTRUCTION SERVICES HOME PAGE | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2010-02-01 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2010-02-01 |
Time |
16:46 |
Rev Time |
0.55 |
Received By |
jwitmer |
Date |
2010-02-01 |
Time |
16:45 |
Sent To |
|
|
Notes |
2010-02-01 16:47:54 | BUILDING PLAN REVIEW | | PERMIT: 10010061 | | ADD: 4335 EASLEY ST | | CONT: MURRY LOGAN | | TEL: (561)686-3948 | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | W/ 2009 FBC SUPPLEMENTS | | * WEST PALM BEACH AMENDMENTS | | | | 1ST REVIEW | | ACTION: DENIED | | | | 1) PLANS FAIL TO INDICATE THE WIND DESIGN CRITERIA: | | 1603.1.4 WIND DESIGN DATA. | | THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL | | BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE | | DESIGN OF THE LATERAL-FORCE-RESISTING SYSTEM OF THE | | BUILDING: | | 1.1. BASIC WIND SPEED (3-SECOND GUST), MILES PER HOUR | | (KM/HR). | | | | 1.2. WIND IMPORTANCE FACTOR, I W , AND BUILDING | | CLASSIFICATION FROM TABLE 1604.5 OR TABLE 6-1, ASCE 7 | | AND BUILDING CLASSIFICATION IN TABLE 1-1, ASCE 7. | | | | 1.3. WIND EXPOSURE, IF MORE THAN ONE WIND EXPOSURE IS | | UTILIZED, THE WIND EXPOSURE AND APPLICABLE WIND | | DIRECTION SHALL BE INDICATED. | | | | 1.4. THE APPLICABLE ENCLOSURE CLASSIFICATIONS AND, IF | | DESIGNING WITH ASCE 7, INTERNAL PRESSURE COEFFICIENT. | | | | 1.5. COMPONENTS AND CLADDING. THE DESIGN WIND PRESSURES | | IN TERMS OF PSF (KN/M 2 ) TO BE USED FOR THE SELECTION | | OF EXTERIOR COMPONENTS AND CLADDING MATERIALS NOT | | SPECIFICALLY DESIGNED BY THE REGISTERED DESIGN | | PROFESSIONAL. | | | | 2) SHEET# 9 NOTE# 5 INDICATES THE STAIR GUARD-RAIL NOT | | SHOWN FOR CLARITY, PLEASE PROVIDE COMPLIANCE WITH | | 1013.3. | | | | 3) SHEET# 9 HANDRAIL DETAIL INDICATES HANDRAIL TO | | COMPLY WITH SBC, THE STANDARD BUILDING CODE HAS NOT | | BEEN EFFECT SINCE THE FLORIDA BUILDING CODE WAS ADOPTED | | STATE WIDE, CURRENTLY UNDER THE 2007 FLORIDA BUILDING | | CODE WITH 2009 SUPPLEMENTS. | | | | STARTING AUGUST 21, 2009, THE CONSTRUCTION SERVICES | | DEPARTMENT WILL BE CLOSED ON FRIDAYS UNTIL FURTHER | | NOTICE. | | | | OPENING HOURS MONDAY - THURSDAY WILL REMAIN AT 8:00 AM | | - 5:00 PM. | | | | JIM WITMER C. B. O. | | BUILDING PLAN REVIEW II | | | | TEL: (561)805-6715 | | FAX: (561)805-6731 | | E-MAIL: [email protected] | | | | PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE | | CUSTOMER SERVICE SURVEY AT: | | WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES | | | | CONSTRUCTION SERVICES HOME PAGE | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2010-03-17 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2010-04-12 |
Time |
09:41 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2010-04-12 |
Time |
09:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2010-02-01 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2010-02-01 |
Time |
16:20 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2010-02-01 |
Time |
16:13 |
Sent To |
|
|
Notes |
2010-02-01 16:21:01 | ** DENIED REVIEW * | | | | 1) NOTE: NO DESIGN CODES ON PLANS FOR PERMIT | | APPLICATION MADE AFTER OCTOBER 1ST, 2009. | | SHOULD HAVE THE FOLLOWING AT A MINIMUM. | | 2008 NFPA-70 | | | | 2) NOTE: PLEASE SUBMIT COMPLETED ELECTRICAL PLANS. | | FOR EXAMPLE: SHEET 8 STATES TO SEE SHEET #9 FOR | | MODIFIED ELECTRICAL POWER PANEL HOWEVER SHEET #9 HAS NO | | ELECTRICAL INFORMATION. | | PLEASE SUBMIT CIRCUITING, PANELS, LOADS, INFORMATION ON | | LIGHT POLES, BRANCH CIRCUITS, SIZES FOR CONDUCTORS, | | BREAKERS ETC.ETC. | | 220,215.5.230, 225, 408.4, 310.16 | | | | SECTIONS GIVEN IN GENERAL AS PLANS ARE NOT ENTIRELY | | CLEAR FOR ELECTRICAL SCOPE OF WORK. | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | CONTACT THIS REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
P |
Date |
2010-04-16 |
|
|
Cont ID |
|
Sent By |
efabian |
Date |
2010-04-16 |
Time |
10:26 |
Rev Time |
0.25 |
Received By |
efabian |
Date |
2010-04-16 |
Time |
10:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2010-02-03 |
|
|
Cont ID |
|
Sent By |
dlauderm |
Date |
2010-02-03 |
Time |
14:17 |
Rev Time |
3.00 |
Received By |
dlauderm |
Date |
2010-02-03 |
Time |
14:17 |
Sent To |
|
|
Notes |
2010-02-03 15:23:47 | ENGINEERING REVIEWER: | | DEAN S. LAUDERMILK, PROJECT COORDINATOR | | PHONE: 561-494-1083, FAX: 561-494-1116 | | EMAIL: [email protected] | | 1ST REVIEW, FAILED. | | | | GENERAL COMMENTS: | | 1. CITY ENGINEERING APPROVED MATERIALS LIST (AML) NEEDS | | TO BE USED WHENEVER MATERIALS USED ARE LISTED IN THE | | MANUAL. SUCH ITEMS INCLUDE THE 12" LINE AND THE 4" LINE | | AND WALL SLEEVES. THE AML CAN BE FOUND AT | | HTTP://WWW.WPB.ORG/ENGINEERING/ENG_FORMS.PHP , IT IS | | THE SEVENTH FORM LISTED. | | | | SHEET 5: | | 1. PIPE PENETRATIONS ARE TO HAVE WALL SLEEVES USED. | | 1-A. THE NEW 12" LINE GOING THRU THE NEW RECEIVING TANK | | AND INTO THE WETWELL WILL NEED TO USE THE SLEEVES. | | 1-B. SO WILL THE 4" DRAIN LINE. | | 1-C. THE TWO DUMP LINES (4 AND 3" INTO THE NEW | | RECEIVING TANK WILL NEED WALL SLEEVES ALSO. | | 1-D. THE 12" LINE AND THE 4" LINE PENETRATION WILL NEED | | TO HAVE HOLES CORED INTO THE WETWELL. THE HOLES WILL | | NEED TO BE 4" (MINIMUM) LARGER THAN THE OUTSIDE OF THE | | SLEEVES USED. THE SIZE OF THE HOLES LISTED WILL NOT | | WORK. | | 2. "PROPOSED CURB DRAIN" IS SHOWN AT THE RIGHT SIDE OF | | THE PLAN: | | 2-A. IT APPEARS TWO ARE SHOWN, BUT WHERE ARE THE PIPES | | THAT DRAIN FROM THEM? THERE ARE NO DETAILS FOR THE CURB | | DRAINS, DO YOU MEAN TO BUILD A CURB WITH FLUMES THRU | | THE CURBS? THIS IS TOTALLY UNCLEAR. SEE 2-B | | 2-B. CROSS SECTION ON SHEET 5, B/S7 SHOWS THE CONCRETE | | SLAB, EAST OF THE CONCRETE DRIVEWAY IS TO BE THE SAME | | ELEVATION AS THE CONCRETE DRIVEWAY, WHY NOT RAISE UP | | THE EAST SLAB SO IT IS LEVEL WITH THE TOP OF THE CURB, | | THEN NO FLUMES WOULD BE NEEDED AND THE SLAB EAST OF THE | | CURBS WILL DRAIN ACROSS THE CURBS. | | 3. THE NOTE "SLOPE PROPOSED CONCRETE PAD AND REPAIRED | | ASPHALT PAVEMENT TOWARDS PROPOSED ROADWAY DRAIN. THERE | | IS NO APPARENT ASHPHALT, EXCEPT TO THE EAST OF THE | | CONSTRUCTION. WHERE THE ARROW IS POINTING IS ALL NEW | | CONCRETE. CALL OUT WHERE ANY NEW ASPHALT IS TO BE | | INSTALLED. | | 4. A HOSE BIB IS SHOWN ON THE NORTH SIDE OF THE NEW | | RECEIVING TANK, I WOULD SUGGEST ANOTHER BE INSTALLED | | WHERE THE LINE IS TIED BACK IN NEAR THE WETWELL. ALSO, | | THE HOSE BIB(S) WILL BE SIGNED "NON-POTABLE WATER" | | SINCE IT IS ON THE PROCESS WATER LINE, CORRECT? | | 5. 2 - 3" 90 DEGREE BENDS ARE SHOWN ON THE RELOCATED | | PROCESS WATER LINE. ON SHEET 6 THE ELBOWS SHOWN ARE 45 | | DEGREE BENDS. WHICH IS IT? IF THE ELBOWS ON SHEET 6 ARE | | THE EXISITNG, WHERE ARE THE NEW 90 DEGREE BENDS AND | | THREE WOULD NEED TO BE USED, NOT TWO AS SHOWN. | | | | SHEET 6: | | 1. THE ROUTING OF THE NEW 3" WATER LINE IS NOT SHOWN, | | HOW WILL THE LINE BE OFFSET DOWN WITH 1 - 90 DEGREE | | BEND AND THEN EAST WITH 1 - 90 DEGREE BEND TO THE EAST, | | AND NOT HAVE IT CONFLICT WITH THE 12" AND 4" DRAIN | | LINES? | | | | SHEET 7: | | 1. THE SECONDARY POUR IN THE BOTTOM OF THE TANK SHOULD | | END AT THE SAME ELEVATION AS THE INVERT OF THE 12" LINE | | LEAVING THE TANK, NOT AS SHOWN. ALSO, SEE COMMENT 1-A | | FOR SHEET 5 THE SLEEVE WILL SET THE INVERT OF THE 12" | | HIGHER. | | 2. A PREFORMED WATER STOP AND KEY WAY IS PROPOSED WHERE | | THE 12" LINE EXITS THE TANK, THIS WILL NOT WORK, THE | | KEYWAY WILL NEED TO BE ABOVE THE WATER STOP. EITHER | | LOWER THE BOTTOM SLAB, OR RAISE THE 12" PIPE. | | 3. A 1/4" THICK ALUMIUM DIMOND PLATE IS TO BE USED TO | | COVER THE TANK. WILL THIS BE SAFE ENOUGH FOR A PERSON | | TO WALK ON? | | | | SHEET 8: | | 1. A WALL SLEEVE WILL BE REQUIRED FOR THE WALL | | PENETRATION. THE HOLE FOR THE 8" PIPE WILL NEED TO BE | | LARGE THAN WHAT IS CALLED OUT (12"). | | | | ADDITIONAL NOTES: | | PLUMBING REVIEW K. STEVENS FAILED PLAN DUE TO THE | | DUMPSTER PAD IS NOT ROOFED AND THE CATCH BASIN DRAINS | | INTO THE SEPTAGE WETWELL. I EXPLAINED THAT WE CAN NOT | | ALLOW THE FLUIDS TO DRAIN INTO A STORM DRAINAGE SYSTEM, | | BUT THAT THEY NEED TO GO BACK INTO THE TREATMENT CYCLE, | | INCLUDING ANY RAIN WATER COLLECTED. HE SHOULD BE | | CHANGING THIS COMMENT, BUT, YOU MAY WANT TO CONTACT HIM | | DIRECTLY. | | | | |
|
|
Review Stop |
ENG-F |
ENGINEERING FINAL DRAWING REV |
Rev No |
1 |
Status |
P |
Date |
2010-04-15 |
|
|
Cont ID |
|
Sent By |
efabian |
Date |
2010-04-15 |
Time |
15:13 |
Rev Time |
1.50 |
Received By |
efabian |
Date |
2010-04-15 |
Time |
15:13 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2010-05-05 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2010-05-05 |
Time |
11:43 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2010-05-05 |
Time |
11:43 |
Sent To |
B |
|
Notes |
2010-05-05 11:44:03 | SENT TO J. WITMER'S DESK. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2010-04-15 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2010-03-18 |
Time |
09:59 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2010-03-18 |
Time |
10:49 |
Sent To |
|
|
Notes |
2010-03-18 11:02:34 | SENT TO C-35 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2010-04-15 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2010-02-03 |
Time |
09:59 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2010-01-11 |
Time |
16:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2010-04-12 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2010-04-12 |
Time |
09:33 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2010-04-12 |
Time |
09:33 |
Sent To |
|
|
Notes |
2010-04-12 09:35:24 | MECHANICAL NOT REQUIRED |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2010-04-08 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2010-04-08 |
Time |
10:20 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2010-04-08 |
Time |
10:20 |
Sent To |
|
|
Notes |
2010-04-08 10:25:58 | FROM REVIEW #1 | | | | 1. OK- DRAIN LINE IS OPEN ON BOTH ENDS, THEREFORE IT IS | | A COMBONATION WASTE AND VENT. | | | | 2. OK- SEPTAGE FROM ROAD IS ROUTED TO TANK. | | | | 3. OK- TRAP PRIMER NOT REQUIRED AS THE DRAIN IS A | | WORKING DRAIN AND NOT AN EMERGENCY DRAIN. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2010-01-12 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2010-01-12 |
Time |
10:58 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2010-01-12 |
Time |
10:58 |
Sent To |
|
|
Notes |
2010-01-12 11:02:36 | DENIED | | REFERENCE: | | FBC-2007 PLUMBING | | CODE OF ORDINANCES CITY WPB | | | | 1. PER SECTION 901.2.1 EVERY TRAP AND TRAPPED FIXTURE | | SHALL BE VENTED. THE FLOOR DRAIN SHALL BE TRAPPED. | | | | 2. PER ARTICLE III SECTION 90-125(5) STORM WATER, | | SURFACE WATER, GROUND WATER ETC. SHALL NOT DRAIN TO THE | | WASTE WATER FACILITY. | | | | 3. PER SECTION 1002.4 WHERE A TRAP SEAL IS SUBJECT TO | | LOSS BY EVAPORATION, A TRAP SEAL PRIMER VALVE SHALL BE | | INSTALLED. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | ONE SET OF THEM LOOSELY ON TOP OF THE | | COLLATED PLANS TO BE REVIEWED. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2010-04-27 |
|
|
Cont ID |
|
Sent By |
ajones |
Date |
2010-04-27 |
Time |
11:50 |
Rev Time |
0.00 |
Received By |
ajones |
Date |
2010-04-27 |
Time |
11:50 |
Sent To |
B |
|
Notes |
2010-04-27 11:57:39 | WITH THE PROVISO THAT ARECA PALMS SHALL BE PLANTED ON | | THE EAST SIDE OF THE NEW RECEIVING TANK. A LANDSCAPE | | PERMIT SHALL BE APPLIED FOR PRIOR TO THE ISSUANCEL OF A | | CO. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2010-04-19 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2010-04-19 |
Time |
18:01 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2010-04-19 |
Time |
18:01 |
Sent To |
|
|
Notes |
2010-04-19 18:02:07 | ZONING PLAN REVIEW | | | | PERMIT NO.: 10010061 | | ADDRESS: 4335 EASLEY DRIVE | | CONTRACTOR/CONTACT: DAVID LOGA | | TELEPHONE NO.: 561.686.3948 | | SCOPE OF REVIEW: CONSTRUCTION OF NEW SEPTAGE RECEIVING | | FACILITY AT THE EAST CENTRAL REGIONAL WATER RECLAMATION | | FACILITY. | | | | REVIEW STATUS: FAILED | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | REVIEW COMMENTS: | | | | THE FOLLOWING COMMENTS ARE REPEAT COMMENTS THAT WERE | | NOT ADDRESSED UPON RESUBMITTAL OF THE REVISED | | PLANS...ADDITIONAL CLARIFICATION IS PROVIDED IN ALL | | CAPS.... | | | | 1) A SITE PLAN SHALL BE PROVIDED SHOWING THE PROPOSED | | IMPROVEMENTS IN RELATION TO ADJACENT PROPERTY LINES. | | DIMENSIONS SHALL BE PROVIDED FOR SETBACKS FROM THE | | FRONT, SIDE, AND REAR PROPERTY LINES. NO OVERALL SITE | | PLAN WAS FOUND IN THE PACKAGE...ONLY A PARTIAL SITE | | PLAN WAS SHOWN AND NO DIMENSIONS WERE PROVIDED FROM THE | | PROPOSED IMPROVEMENTS TO THE ADJACENT PROPERTY LINES. | | | | 2. AN OPAQUE LANDSCAPE BUFFER SHALL BE PROVIDED | | ENTIRELY AROUND THIS INDIVIDUAL UTILITY AREA, OR AROUND | | THE ENTIRE FACILITY, IN ACCORDANCE WITH SECTION | | 94-443(2) OF THE CITY'S ZONING AND LAND DEVELOPMENT | | REGULATIONS. THE EXISTING VEGETATION DOES NOT QUALIFY | | AS AN OPAQUE BUFFER...AND MUCH OF THIS IS LOCATED OFF | | OF THE ECR PROPERTY. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | JOHN ROACH, SENIOR PLANNER | | CITY OF WEST PALM BEACH | | PLANNING AND ZONING DEPARTMENT | | 401 CLEMATIS STREET - P.O. BOX 3366 | | WEST PALM BEACH, FLORIDA 33402 | | | | PHONE: 561.822.1435 | | FAX: 561.822.1460 | | | | EMAIL: [email protected] | | | | WWW.CITYOFWPB.COM | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2010-02-03 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2010-02-03 |
Time |
17:58 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2010-02-03 |
Time |
17:58 |
Sent To |
|
|
Notes |
2010-02-03 17:58:47 | ZONING PLAN REVIEW | | | | PERMIT NO.: 10010061 | | ADDRESS: 4335 EASLEY DRIVE | | CONTRACTOR/CONTACT: DAVID LOGA | | TELEPHONE NO.: 561.686.3948 | | SCOPE OF REVIEW: CONSTRUCTION OF NEW SEPTAGE RECEIVING | | FACILITY AT THE EAST CENTRAL REGIONAL WATER RECLAMATION | | FACILITY. | | | | REVIEW STATUS: FAILED | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | REVIEW COMMENTS: | | | | 1) A SITE PLAN SHALL BE PROVIDED SHOWING THE PROPOSED | | IMPROVEMENTS IN RELATION TO ADJACENT PROPERTY LINES. | | DIMENSIONS SHALL BE PROVIDED FOR SETBACKS FROM THE | | FRONT, SIDE, AND REAR PROPERTY LINES. | | | | 2. AN OPAQUE LANDSCAPE BUFFER SHALL BE PROVIDED | | ENTIRELY AROUND THIS INDIVIDUAL UTILITY AREA, OR AROUND | | THE ENTIRE FACILITY, IN ACCORDANCE WITH SECTION | | 94-443(2) OF THE CITY???S ZONING AND LAND DEVELOPMENT | | REGULATIONS. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | JOHN ROACH, SENIOR PLANNER | | CITY OF WEST PALM BEACH | | PLANNING AND ZONING DEPARTMENT | | 401 CLEMATIS STREET - P.O. BOX 3366 | | WEST PALM BEACH, FLORIDA 33402 | | | | PHONE: 561.822.1435 | | FAX: 561.822.1460 | | | | EMAIL: [email protected] | | | | WWW.CITYOFWPB.COM | | |
|
|