Plan Review Stops For Permit 09120528 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2010-01-14 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2010-01-14 |
Time |
08:33 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2010-01-14 |
Time |
08:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2009-12-30 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-12-30 |
Time |
09:47 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-12-30 |
Time |
07:29 |
Sent To |
|
|
Notes |
2009-12-30 09:47:48 | 2007 FBC W/2009 REVISIONS | | REVISION | | | | DENIED BY BUILDING | | | | 1) THIS PACKAGE SHOULD HAVE BEEN SUBMITTED AS A | | REVISION TO THE PERMITS THAT HAVE ALREADY BEEN ISSUED | | FOR THIS WORK. A NEW PERMIT WILL NOT BE ISSUED. WHEN | | THIS IS RESUBMITTED USE THE PROPER RESUBMITTAL FORM. | | | | 2) SUBMIT 2 SETS OF REVISED PLANS WITH THE CHANGES | | INDICATED BY CLOUDS AND REVISION NUMBER. FBC 106.1 CITY | | AMENDMENTS | | | | 3) THE ONE SET OF PLANS THAT WAS SUBMITTED INDICATES | | THAT A BATH ROOM HAS BEEN ADDED AND THE UTILITY ROOM | | HAS BEEN MOVED. WHEN SPECIFYING THE DESCRIPTION OF WORK | | ON A REVISION FORM PROVIDE THIS INFORMATION. | | | | 4) THE VALUE OF THE ADDITIONAL WORK WILL BE ADDED TO | | THE MASTER PERMIT AND A REVISION FEE WILL BE CHARGED | | FOR THE REVISED SHEETS. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2010-01-19 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2010-01-19 |
Time |
10:31 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2010-01-19 |
Time |
10:18 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2009-12-29 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2009-12-29 |
Time |
13:27 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2009-12-29 |
Time |
13:25 |
Sent To |
|
|
Notes |
2009-12-29 13:27:03 | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | THE 2007 FLORIDA RESIDENTIAL BUILDING CODE, 2009 | | REVISIONS, 2008 NEC, 2004 FBC AS AMENDED, CHAPTER 1.AND | | FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | 1} INDICATE THE CONDUIT AND CONDUCTOR SIZES FROM PANEL | | "A" TO PANEL "B" ON THE RISER. 215.5 | | | | 2} 106.1 SUBMITTAL DOCUMENTS. CONSTRUCTION DOCUMENTS, | | SPECIAL INSPECTION AND STRUCTURAL OBSERVATION PROGRAMS, | | AND OTHER DATA SHALL BE SUBMITTED IN TWO OR MORE SETS | | WITH EACH APPLICATION FOR A PERMIT. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2010-01-11 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2010-01-11 |
Time |
16:16 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2010-01-11 |
Time |
16:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2009-12-30 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-12-30 |
Time |
11:48 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-12-28 |
Time |
16:18 |
Sent To |
|
|
Notes |
2009-12-28 16:18:34 | ZONING IN BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2010-01-14 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2010-01-14 |
Time |
08:33 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2010-01-14 |
Time |
08:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2009-12-30 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-12-30 |
Time |
11:48 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-12-30 |
Time |
11:48 |
Sent To |
|
|
Notes |
2009-12-30 12:21:03 | 2007 FBC W/2009 REVISIONS | | MECHANICAL REVISIONS | | | | DENIED | | | | 1) TWO SETS OF OF REVISED PLANS ARE REQUIRED. | | | | 2) MECHANICAL VENTILATION DISCHARGED TO THE EXTERIOR IS | | REQUIRED IN THE BATHROOMS PER FBCR M 1507.2. THE | | EXHAUST CAPACITY OF 50 CFM INTERMITTENT IS REQUIRED PER | | M 1507.3. | | | | 3) TRANSFER DUCTS ARE REQUIRED TO BE TO BE 1.5 TIMES | | THE CROSS SECTIONAL AREA OF THE SUPPLY DUCT ENTERING | | THE ROOM. PLEASE REVISE. SEE FBCR M 1602.4. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2010-01-14 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2010-01-14 |
Time |
08:34 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2010-01-14 |
Time |
08:33 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2009-12-30 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-12-30 |
Time |
11:12 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-12-30 |
Time |
11:12 |
Sent To |
|
|
Notes |
2009-12-30 11:47:48 | 2007 FBC W/2009 REVISIONS | | PLUMBING REVISIONS | | | | DENIED | | | | 1) TWO SETS OF REVISED PLANS ARE REQUIRED. FBC 106.1 | | CITY AMENDMENTS | | | | 2) PLEASE INDICATE CHANGES FROM THE APPROVED PLANS WITH | | CLOUDS OR OTHER ACCEPTABLE METHODS. | | | | 3) THE PLUMBING RISER DIAGRAM DOES NOT MATCH THE | | ARCHITECTURAL PLANS. | | | | 4) SPECIFY ALL DWV PIPE SIZES ON THE PLANS. FBCR | | P3005.4 | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|