Plan Review Stops For Permit 09120451 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2010-03-02 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2010-03-02 |
Time |
08:59 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2010-03-02 |
Time |
08:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2009-12-29 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-12-29 |
Time |
13:49 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-12-29 |
Time |
13:48 |
Sent To |
|
|
Notes |
2009-12-29 16:37:26 | 2007 FBC W/2009 REVISIONS | | LEVEL 3 ALTERATION | | | | DENIED BY BUILDING | | | | 1) THE PLANS ARE REQUIRED TO BE PREPARED, SIGNED, | | SEALED AND DATED BY A FLORIDA LICENSED ARCHITECT OR | | ENGINEER. FS 481.229 AND FS 471.003 | | | | 2) PER 405.1, THE WORK AREA EXCEEDS 50 PERCENT OF THE | | AGGREGATE AREA OF THE BUILDING, WHICH MAKES THIS A | | LEVEL 3 ALTERATION. PLEASE CORRECT. | | | | 3) IF THIS IS A 3-UNIT APARTMENT BUILDING, THE | | OCCUPANCY TYPE IS R-2. PLEASE CORRECT. SEE FBC 310.1 | | | | 4) THE ENERGY CALCULATION FORM NEEDS TO BE SIGNED BY | | THE OWNER AS WELL AS THE PREPARER. FBC 13-103.1.1.2.2 | | REQUIRES THE FORM PREPARATION FOR MULTI-FAMILY | | DWELLINGS TO BE SIGNED AND SEALED BY AN ARCHITECT OR | | ENGINEER REGISTERED IN THE STATE OF FLORIDA. | | | | 5) PLEASE NOTE ON THE PLANS THAT THE EXISTING TENANT | | SEPARATION WALLS, AS WELL AS, THE FLOOR/CEILING | | SEPARATING TENANT SPACES ARE REQUIRED TO HAVE A ONE | | HOUR FIRE RATING PER FBC 708.1 AND FBC 711.3. THE | | BATHROOM LOCATED UNDER THE STAIRS IS REQUIRED TO HAVE | | ONE HOUR FIRE SEPARATION FROM THE STAIRS LEADING TO THE | | UNIT ABOVE. | | | | 6) SPECIFY THE WIND DESIGN INFORMATION INCLUDING WIND | | SPEED, EXPOSURE CATEGORY, ETC. ON THE PLANS. SEE FBC | | 1603.1.4. | | | | 7) SPECIFY THE REQUIRED COMPONENT AND CLADDING | | PRESSURES FOR THE WINDOW AND DOOR OPENINGS ON THE | | PLANS. SEE FBC 1604.9. THE ONES SPECIFIED ON THE PLANS | | ARE NOT CORRECT. | | | | 8) PROVIDE THE UL LISTING OR FILE NUMBER FROM AN | | APPROVED TESTING AGENCY FOR THE 1 HOUR FIRE RATED WALL | | SYSTEM THAT WILL BE INSTALLED. SEE FBC 703. | | | | 9) PLEASE CLARIFY WHICH WINDOWS ARE TO BE REPLACED AND | | WHICH OF THE EXISTING ONES WILL REMAIN. PLEASE NOTE | | THAT A 37 X 50 WINDOW DOES NOT MEET EGRESS SIZE | | REQUIREMENTS. SEE FBC 1026. | | | | 10) SUBMIT PRODUCT APPROVALS FOR THE HORIZONTAL SLIDING | | WINDOWS PER FAC RULE 9B-72, IF THEY ARE TO BE REPLACED. | | | | 11) THE PRODUCT APPROVALS ARE REQUIRED TO BE REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD FOR | | THE PROJECT. FBC 106.3.3 CITY AMENDMENTS. | | | | 12) THE ROOM HOUSING THE DRYER FOR UNIT # 2 THAT | | LOCATED UNDER THE EGRESS STAIRS FOR UNIT #3 IS REQUIRED | | TO HAVE 1 ONE FIRE RATED WALLS AND CEILING THAT | | SEPARATE IT FROM THE STAIRS AND LANDING OF THE ADJACENT | | TENANT SPACE. FBC 708 AND 711. | | | | 13) SPECIFY DRAFTSTOPPING IN THE COMBUSTIBLE FLOOR | | CONSTRUCTION ABOVE AND IN LINE WITH THE DWELLING UNIT | | SEPARATIONS ON THE PLANS. SEE FBC 717.3. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2010-02-23 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2010-02-23 |
Time |
16:06 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2010-02-23 |
Time |
15:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2009-12-28 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2009-12-28 |
Time |
12:35 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2009-12-28 |
Time |
11:43 |
Sent To |
|
|
Notes |
2009-12-28 12:35:06 | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | THE 2007 FLORIDA RESIDENTIAL BUILDING CODE, 2009 | | REVISIONS, 2008 NEC, 2004 FBC AS AMENDED, CHAPTER 1.AND | | FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | ALL COMMENTS RELATE TO SHEET 1 OF 4, UNLESS OTHERWISE | | NOTED. ALL CODE ARTICLES REFERENCED ARE 2008 NEC UNLESS | | OTHERWISE NOTED. | | | | 1} THE LOAD CALCULATION INDICATES A 400 AMP SERVICE | | WITH 1/0 CONDUCTORS, THE RISER DIAGRAM INDICATES 350 | | MCM (AND A 3/0???) BOTH OF WHICH DO NOT COMPLY WITH | | 310.15 (B)(6) FOR CONDUCTOR SIZE. 400 MCM WOULD BE | | CORRECT FOR A 400 AMP SERVICE, AND NO GROUND WIRE IN | | THE RISER.ALSO SEE 250.94 FOR INTERSYSTEM BONDING. | | | | THE ELECTRICAL NOTE REGTARDING ARC FAULT BREAKERS IN | | THE BEDROOMS IS INCORRECCT, SEE 210.12 2008 NEC. | | | | 3} THE PANEL LOCATION IN UNIT #3 IS IN VIOLATION OF | | 240.24 (D), CLOTHES CLOSET. | | | | 4} UNIT #1NEEDS A RECEPTACLE ADDED TO THE KITCHEN | | COUNTERTOP TO COMPLY WITH210.52 (C)(1) SPACING. SEE | | REVIEWED PLAN. | | | | 5} THE GROUNDING ELECTRODE CONDUCTOR MUST COMPLY WITH | | 250.66. SEE NOTE #1 REGARDING THE SUM OF THE SERVICE | | ENTRANCE CONDUCTORS. | | | | 6} THE EQUIPMENT GROUND BETWEEN THE METER AND | | DISCONNECT ON THE RISER DIAGRAM CREATES A PARALLEL PATH | | TO GROUND WITH THE NEUTRAL AND MUST BE REMOVED. AN | | ISOLATED NEUTRAL AND EQUIPMENT GROUND ARE TO BE RAN | | FROM THE FIRST MEANS OF DISCONNECT. 250.6. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW. | | CITY OF WEST PALM BEACH | | 561/805-6718 | | [email protected] | | FAX/:561/805-6676 | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2010-02-24 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2010-02-24 |
Time |
15:11 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2010-02-24 |
Time |
14:58 |
Sent To |
|
|
Notes |
2010-02-24 15:09:24 | *****APPROVED***** | | | | THE COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEW HAVE | | BEEN ADDRESSED; PLAN SHEET 1 (OF 3) STAMPED, INITIALED, | | AND DATED. | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 | | | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2010-01-11 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2010-01-11 |
Time |
15:52 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2010-01-11 |
Time |
15:26 |
Sent To |
|
|
Notes |
2010-01-11 15:45:48 | *****DENIED***** | | | | | | 1. STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241 - 2004 | | EDITION. | | | | 2. NFPA 101, LIFE SAFETY CODE, 2006 EDITION SHALL BE | | REFERENCED. | | | | 3. SHOW THE LOCATION OF THE PORTABLE 2A:10BC RATED FIRE | | EXTINGUISHERS WHICH SATISFY THE 75' TRAVEL DISTANCE. | | | | 4. SPECIFY THE INTERIOR FINISH MATERIALS FOR THE WALLS | | AND CEILINGS IN TERMS OF CLASS A, CLASS B, OR CLASS C. | | | | 5. DOORS THAT OPEN ONTO EXIT ACCESS CORRIDORS SHALL | | HAVE NOT LESS THAN A 20-MINUTE FIRE PROTECTION RATING. | | | | 6. DOORS THAT OPEN ONTO EXIT ACCESS CORRIDORS SHALL BE | | SELF CLOSING AND SELF LATCHING. | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | LETTER INDICATING HOW/WHERE THE COMMENT WAS ADDRESSED | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 | | | | | | | | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | LETTER INDICATING HOW/WHERE THE COMMENT WAS ADDRESSED | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2010-02-09 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2010-02-09 |
Time |
11:05 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2010-02-09 |
Time |
11:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2010-03-02 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2010-01-21 |
Time |
08:59 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-12-23 |
Time |
13:43 |
Sent To |
|
|
Notes |
2009-12-23 13:51:41 | SENT TO R6. |
|
|
Review Stop |
L |
LANDSCAPING |
Rev No |
3 |
Status |
N |
Date |
2010-03-11 |
|
|
Cont ID |
|
Sent By |
rkussner |
Date |
2010-03-11 |
Time |
14:50 |
Rev Time |
0.00 |
Received By |
rkussner |
Date |
2010-03-11 |
Time |
14:50 |
Sent To |
|
|
Notes |
2010-03-11 14:53:05 | ***LANDSCAPE REVIEW IS UNDER PERMIT #10030198. |
|
|
Review Stop |
L |
LANDSCAPING |
Rev No |
2 |
Status |
F |
Date |
2010-02-26 |
|
|
Cont ID |
|
Sent By |
rkussner |
Date |
2010-02-26 |
Time |
13:57 |
Rev Time |
0.00 |
Received By |
rkussner |
Date |
2010-02-26 |
Time |
13:57 |
Sent To |
|
|
Notes |
2010-02-26 14:01:10 | ***LANDSCAPE REVIEW FAILED*** | | | | COMMENTS MADE ON 2/3/10 HAVE NOT BEEN ADDRESSED. THE | | RESPONSE TO THOSE COMMENTS WAS THAT A LANDSCAPE PERMIT | | WOULD BE COMING IN FOR REVIEW. THIS HAS NOT OCCURRED. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT | | KUSSNER @ (561) 822-1462. |
|
|
Review Stop |
L |
LANDSCAPING |
Rev No |
1 |
Status |
F |
Date |
2010-02-03 |
|
|
Cont ID |
|
Sent By |
rkussner |
Date |
2010-02-03 |
Time |
12:27 |
Rev Time |
0.00 |
Received By |
rkussner |
Date |
2010-02-03 |
Time |
12:27 |
Sent To |
|
|
Notes |
2010-02-03 12:34:14 | ***LANDSCAPE REVIEW FAILED*** | | | | PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN WRITTEN | | FORMAT. | | | | 1. PURSUANT TO SECTION 94-441(C)(2) OF THE ZONING AND | | LAND DEVELOPMENT REGULATIONS (ZLDR): AS THE VALUE OF | | THE PROPOSED WORK EXCEEDS 50% OF THE STRUCTURE'S VALUE | | (LISTED AS "IMPROVEMENT VALUE" WITH THE P.B.C. PROPERTY | | APPRAISER'S OFFICE), LANDSCAPING SHALL BE IN COMPLIANCE | | WITH ALL APPLICABLE REGULATIONS FOUND IN ARTICLE XIV OF | | THE ZLDR. | | | | 2. PLEASE SUBMIT TWO (2) COPIES OF A LANDSCAPE PLAN | | SIGNED AND SEALED BY A REGISTERED LANDSCAPE ARCHITECT, | | SHOWING COMPLIANCE WITH SECTIONS 94-442 AND 94-445 OF | | THE ZLDR. A SEPARATE LANDSCAPE PERMIT IS REQUIRED. A | | COST ESTIMATE THAT INCLUDES THE TOTAL COST OF ALL | | LANDSCAPE MATERIALS AND LABOR, BROKEN DOWN INTO UNIT | | COST SHALL BE SUBMITTED WITH THE LANDSCAPE PLAN. | | | | 3. PURSUANT TO SECTION 94-448 (D) (2), THE LANDSCAPE | | PLAN SHALL INCLUDE THE REQUIRED CALCULATIONS AND ALL | | OTHER ITEMS FOUND IN THIS SECTION. | | | | 3. AN IRRIGATION PERMIT IS REQUIRED. PLEASE SUBMIT TWO | | COPIES OF AN IRRIGATION PLAN THAT COMPLIES WITH ARTICLE | | XIV OF THE ZONING AND LAND DEVELOPMENT REGULATIONS. | | IRRIGATION IS REQUIRED IN THE RIGHT-OF-WAY. | | | | IF YOU HAVE ANY QUESTIONS, PLEAST CONTACT ROBERT | | KUSSNER @ (561) 822-1462. | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
N |
Date |
2010-03-15 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2010-03-15 |
Time |
10:09 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2010-03-15 |
Time |
10:09 |
Sent To |
|
|
Notes |
2010-03-15 10:10:48 | PLANS AND PERMIT REQUIRED FOR MECHANICAL |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2010-03-11 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2010-03-11 |
Time |
13:20 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2010-03-11 |
Time |
13:20 |
Sent To |
|
|
Notes |
2010-03-11 13:27:40 | PLEASE REFER TO SECTION 301.12 WIND RESISTANCE . AND | | SECTION 607.6.2.1 CEILING RADIATION DAMPERS . | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2010-01-13 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2010-01-13 |
Time |
10:20 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2010-01-13 |
Time |
09:51 |
Sent To |
|
|
Notes |
2010-01-13 11:07:02 | PLAN DENIED | | 1) PAGE 4 SHOWS A 7'' FLEX DUCT PENETRATING THE ONE | | HOUR STAIR ENCLOSURE . FLEXIBLE DUCT SHALL NOT PASS | | THROUGH ANY FIRE -RESISTANCE -RATED ASSEMBLY SECTION | | 607.7 FBC-M . | | 2) PENETRATIONS INTO AND OPENINGS THROUGH AN EXIT | | INCLOSURE ARE PROHIBITED EXCEPT FOR EXIT DOORS IN | | ACCORDANCE WITH FBC-B 1020.1.2 . | | 3) PLEASE SHOW WHERE THE BATH EXHAUST TERMINATES ON THE | | PLANS SECTION 401.5 FBC-M . | | 4) SHOW TERMINATION OF CONDENSATE LINES ON PLANS . | | 5) PLEASE REFER TO SECTION 602.2.1METERIALS EXPOSED | | WITHIN PLENUM'S . | | 6) PROVIDE MANUFACTURER'S DATA FOR THE PTAC UNITS ON | | FIRST FLOOR SHOWING THE APPLIANCE ARE DESIGNED FOR WIND | | RESISTANCE SECTION 301.12 FBC-M .ALSO PROVIDE AN | | ENGINEERED WIND RESISTANT INSTALLATION DETAIL FOR THE | | PTAC SLEEVE AS WELL FOR THE ATTACHMENT OF THE UNIT | | WITHIN THE SLEEVE . | | 7) PLEASE BE ADVISED THAT THE ENERGY CALCULATIONS DO | | NOT MATCH THE PLANS . | | 8) PLEASE SHOW THE LOCATION AND THE SIZE OF THE RETURN | | AIR IN THE LIVING SPACE ON ALL THREE UNITS . | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2010-02-23 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2010-02-23 |
Time |
14:41 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2010-02-23 |
Time |
14:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2010-01-04 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2010-01-04 |
Time |
14:29 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2010-01-04 |
Time |
14:29 |
Sent To |
|
|
Notes |
2010-01-04 15:42:24 | DENIED | | REFERENCE: | | FBC-2007 PLUMBING | | FBC-2007 CHAPTER 1 | | FLORIDA ADMINISTRATIVE CODE | | FLORIDA STATUTES | | | | 1. PLANS SHALL BE DESIGNED BY A PROFESSIONAL DESIGN | | PROFESSIONAL. FS 471.003 OR FS 481.229. THE ORIGINAL | | PLANS SUBMITTED FOR THIS ADDRESS UNDER PERMIT NUMBER | | 09090386 SIGNED & SEALED BY V. MIKE STANMIROVIC PE36907 | | APPEARS TO BE THE SAME PLANS NOW BEING SUBMITTED WITH | | HAND DRAWN CHANGES. THE PE OF RECORD HAS BEEN NOTIFIED | | OF THIS. | | | | 2. SUBMIT AN EXISTING FLOOR PLAN FOR THE FIRST & SECOND | | FLOORS TO VERIFY THE EXTENT OF ALTERATION. SECTION | | 106.1.1. | | | | 3. AN ISOMETRIC SANITARY RISER DIAGRAM FOR ALL PLUMBING | | CHANGES ON THE FIRST FLOOR SHALL BE SUBMITTED. SHOW ALL | | PIPE SIZES, TRAPS, VENTS AND INDICATE PIPE MATERIAL. | | SECTIONS 106.3.5.1.3, 701.1 & 901.1. | | | | 4. AN ISOMETRIC WATER RISER DIAGRAM FOR ALL PLUMBING | | CHANGES ON THE FIRST FLOOR SHALL BE SUBMITTED. SHOW ALL | | PIPE SIZES, VALVES & WHERE REQUIRED BY SECTION 604.9, | | WATER HAMMER ARRESTORS. WATER HAMMER ARRESTORS SHALL BE | | LOCATED NEAR THE FIXTURE, IN AN "EFFECTIVE RANGE" PER | | PDI-WH 201. | | | | 5. SHT 2 OF 4 SANITARY RISER DIAGRAM DOES NOT REFLECT | | THE FLOOR PLAN. THE BATHROOM AT THE TOP OF THE STAIRS | | BY THE KITCHEN IS NOT SHOWN ON THE SANITARY RISER | | DIAGRAM. SECTIONS 106.1.1 & 701.1. | | | | 6. AN ISOMETRIC WATER RISER DIAGRAM FOR ALL PLUMBING | | CHANGES ON THE SECOND FLOOR SHALL BE SUBMITTED. | | SECTIONS 106.3.1.5.3 & 601.1. SHOW ALL PIPE SIZES, | | VALVES & WHERE REQUIRED BY SECTION 604.9, WATER HAMMER | | ARRESTORS. WATER HAMMER ARRESTORS SHALL BE LOCATED NEAR | | THE FIXTURE, IN AN "EFFECTIVE RANGE" PER PDI-WH 201. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | ONE SET OF THEM LOOSELY ON TOP OF THE | | COLLATED PLANS TO BE REVIEWED. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2010-02-18 |
|
|
Cont ID |
|
Sent By |
astelly |
Date |
2010-02-12 |
Time |
17:41 |
Rev Time |
0.00 |
Received By |
astelly |
Date |
2010-02-12 |
Time |
09:00 |
Sent To |
|
|
Notes |
2010-02-12 17:41:01 | AMY STELLY | | PLANNING AND ZONING | | 822-1442 | | | | PASSED W/ PROVISO | | LANDSCAPE PLAN MUST BE SUBMITTED FOR REVIEW. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2010-01-21 |
|
|
Cont ID |
|
Sent By |
astelly |
Date |
2010-01-21 |
Time |
17:53 |
Rev Time |
0.00 |
Received By |
astelly |
Date |
2010-01-21 |
Time |
17:53 |
Sent To |
L |
|
Notes |
2010-01-21 17:54:30 | AMY STELLY | | PLANNING AND ZONING | | 822-1442 | | | | PLEASE PROVIDE A RECENT SURVEY OF THE PROPERTY. |
|
|