Plan Review Stops For Permit 09120273 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2010-02-08 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2010-02-08 |
Time |
16:38 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2010-02-08 |
Time |
16:38 |
Sent To |
|
|
Notes |
2010-02-08 16:42:24 | REVISED STORM PANEL INSTALLATION PLAN WAS SUBMITTED AND | | APPROVED. STORM PANEL INSTALLATION SCHEDULE AND PRODUCT | | APPROVALS WERE REVIEWED FOR CODE COMPLIANCE. PRODUCT | | APPROVALS FOR FIRE RATED METAL WINDOW FRAMES WERE | | REVIEWED FOR CODE COMPLIANCE. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2010-02-02 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2010-02-02 |
Time |
11:15 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2010-02-02 |
Time |
09:42 |
Sent To |
|
|
Notes |
2010-02-01 16:59:03 | REVISION TO 09100241 | | | | REVISED SHEETS A2.1, A3.1, A4.1, A5.2 AND A5.3 ARE OK. | | | | STORM PANEL SUBMITTALS ARE DENIED BY BUILDING. | | | | 1) THE STORM PANEL INSTALLATION SCHEDULE IS NOT | | COMPLETED. THE WALL PRESSURES THAT ARE SPECIFIED ON THE | | FORM ARE FOR OPENINGS OF 20 SQUARE FEET. | | | | 2) THE WINDOW SIZES ON THE STORM PANEL SCHEDULE DO NOT | | CORRESPOND WITH THE ONES ON THE PLANS (A2.1). PLEASE | | CORRECT. | | | | 3) THE LETTER TO THE BUILDING OFFICIAL REQUESTING THE | | USE OF STORM PANELS IS REQUIRED TO BE FROM THE BUSINESS | | OWNER. IN ADDITION TO THE STORE OWNER, SPECIFY AN | | ALTERNATE PERSON THAT WILL BE RESPONSIBLE FOR | | INSTALLING THE STORM PANELS IF THE OWNER IS NOT | | AVAILABLE. | | | | 4) THE LETTER INDICATES THAT THE STORM PANELS WILL BE | | STORED IN THE ATTIC. PLEASE SPECIFY THE SIZE OF THE | | ATTIC ACCESS OPENING. | | | | 5) THE PRODUCT APPROVAL DRAWINGS THAT WERE SUBMITTED | | (08-142) ARE FOR 24GA. STEEL PANELS, WHICH WILL ADD A | | SUBSTANTIAL LIVE LOAD TO THE ATTIC. SUBMIT DETAILS FOR | | THE STRUCTURE OF THE CEILING SHOWING THAT THE LOADS | | WILL BE SAFELY SUPPORTED. | | | | 6) THE LETTER ALSO NEEDS TO STATE THAT THE TOOLS AND | | EQUIPMENT (SUCH AS LADDERS) REQUIRED FOR INSTALLING THE | | PANELS WILL ALSO BE STORED ON SITE. | | | | 7) PLEASE CLARIFY THE PURPOSE OF THE FLEMING STEEL DOOR | | AND FRAME UL FOLLOW-UP INFORMATION THAT WAS ATTACHED TO | | THE STORM PANEL SUBMITTAL. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2009-12-28 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-12-28 |
Time |
11:40 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-12-28 |
Time |
11:40 |
Sent To |
|
|
Notes |
2009-12-28 12:24:37 | REVISION TO 09100241 | | | | DENIED BY BUILDING | | | | 1) THE REVISED PLANS DO NOT SHOW COMPLIANCE WITH | | ACCESSIBILITY REQUIREMENTS FOR FIXED SEATING AND | | TABLES, COUNTER-TOP HEIGHTS AND REQUIRED CLEAR FLOOR | | SPACE. SHOW COMPLIANCE WITH FBC 11-4.32, 4.33, 5.1 AND | | 5.2. | | | | 2) REVISE THE HANDRAIL DETAIL IN SECTION E ON SHEET | | A2.1 TO COMPLY WITH FBC 11-4.9.4(3) WHICH REQUIRES THE | | CLEAR SPACE BETWEEN HANDRAILS AND THE WALL TO BE | | 1-1/2". THIS IS AN ABSOLUTE DIMENSION. IN THE DETAIL | | THIS MEASUREMENT IS SHOWN TO THE MOUNTING BRACKET | | FLANGE, NOT THE WALL. | | | | 3) IN SECTION B ON SHEET A2.1 A PORTION OF THE TEXT HAS | | BEEN DELETED. PLEASE CORRECT. | | | | 4) ON THE CEILING PLAN ON SHEET A3.1 THERE SHOULD BE AN | | ADDITIONAL DIRECTIONAL EXIT SIGN AT THE TOP OF THE | | STAIRS SHOWING THE DIRECTION OF EGRESS TO THE EXIT | | DOORS. FBC 1006.3.8 | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2010-01-06 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2010-01-06 |
Time |
11:30 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2010-01-06 |
Time |
10:01 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2010-02-02 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2010-02-02 |
Time |
15:48 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2010-02-02 |
Time |
15:35 |
Sent To |
|
|
Notes |
2010-02-02 15:42:22 | *****REVISION APPROVED***** | | | | | | REVISED PLAN SHEETS A2.1 AND A3.1 STAMPED, INITIALED, | | AND DATED. | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2009-12-29 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2009-12-29 |
Time |
13:07 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2009-12-29 |
Time |
12:55 |
Sent To |
|
|
Notes |
2009-12-29 12:55:50 | *****PARTIAL APPROVAL, FIRE-STAMPING NEEDED***** | | | | | | REVISED PLAN SHEETS A2.1, A3.1, AND E2.01 TO BE | | FIRE-STAMPED WHEN THE OTHER TRADES' PLAN EXAMINER | | COMMENTS HAVE BEEN ADDRESSED. | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2010-02-04 |
Time |
08:53 |
Sent To |
|
|
Notes |
2010-02-04 08:53:44 | INCOMING SENT TO R. MC DOUGAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2010-01-19 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2010-01-19 |
Time |
10:27 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2010-01-19 |
Time |
10:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2009-12-14 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-01-06 |
Time |
15:35 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2009-12-14 |
Time |
15:35 |
Sent To |
PC |
|
Notes |
2010-01-06 11:33:33 | FAILED ARCHITECTURAL SHEETS IN HOLDING BIN UNDER "B", | | PASSED ELECTRICAL 7 PLUMBING SHEETS UP FRONT UNDER | | "B"./WRT. | 2009-12-14 15:36:57 | C22 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2010-01-05 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2010-01-05 |
Time |
13:47 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2010-01-05 |
Time |
13:47 |
Sent To |
|
|
Notes |
2010-01-05 13:48:41 | REVISIONS OK -- SHTS P1.01, P2.01 & P2.02. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
2009-12-24 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2009-12-24 |
Time |
11:21 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2009-12-24 |
Time |
11:21 |
Sent To |
|
|
Notes |
|
|