Plan Review Details - Permit 09120273
Plan Review Stops For Permit 09120273
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2010-02-08 Cont ID  
Sent By rmcdouga Date 2010-02-08 Time 16:38 Rev Time 0.00
Received By rmcdouga Date 2010-02-08 Time 16:38 Sent To  
Notes
2010-02-08 16:42:24REVISED STORM PANEL INSTALLATION PLAN WAS SUBMITTED AND
 APPROVED. STORM PANEL INSTALLATION SCHEDULE AND PRODUCT
 APPROVALS WERE REVIEWED FOR CODE COMPLIANCE. PRODUCT
 APPROVALS FOR FIRE RATED METAL WINDOW FRAMES WERE
 REVIEWED FOR CODE COMPLIANCE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2010-02-02 Cont ID  
Sent By rmcdouga Date 2010-02-02 Time 11:15 Rev Time 0.00
Received By rmcdouga Date 2010-02-02 Time 09:42 Sent To  
Notes
2010-02-01 16:59:03REVISION TO 09100241
  
 REVISED SHEETS A2.1, A3.1, A4.1, A5.2 AND A5.3 ARE OK.
  
 STORM PANEL SUBMITTALS ARE DENIED BY BUILDING.
  
 1) THE STORM PANEL INSTALLATION SCHEDULE IS NOT
 COMPLETED. THE WALL PRESSURES THAT ARE SPECIFIED ON THE
 FORM ARE FOR OPENINGS OF 20 SQUARE FEET.
  
 2) THE WINDOW SIZES ON THE STORM PANEL SCHEDULE DO NOT
 CORRESPOND WITH THE ONES ON THE PLANS (A2.1). PLEASE
 CORRECT.
  
 3) THE LETTER TO THE BUILDING OFFICIAL REQUESTING THE
 USE OF STORM PANELS IS REQUIRED TO BE FROM THE BUSINESS
 OWNER. IN ADDITION TO THE STORE OWNER, SPECIFY AN
 ALTERNATE PERSON THAT WILL BE RESPONSIBLE FOR
 INSTALLING THE STORM PANELS IF THE OWNER IS NOT
 AVAILABLE.
  
 4) THE LETTER INDICATES THAT THE STORM PANELS WILL BE
 STORED IN THE ATTIC. PLEASE SPECIFY THE SIZE OF THE
 ATTIC ACCESS OPENING.
  
 5) THE PRODUCT APPROVAL DRAWINGS THAT WERE SUBMITTED
 (08-142) ARE FOR 24GA. STEEL PANELS, WHICH WILL ADD A
 SUBSTANTIAL LIVE LOAD TO THE ATTIC. SUBMIT DETAILS FOR
 THE STRUCTURE OF THE CEILING SHOWING THAT THE LOADS
 WILL BE SAFELY SUPPORTED.
  
 6) THE LETTER ALSO NEEDS TO STATE THAT THE TOOLS AND
 EQUIPMENT (SUCH AS LADDERS) REQUIRED FOR INSTALLING THE
 PANELS WILL ALSO BE STORED ON SITE.
  
 7) PLEASE CLARIFY THE PURPOSE OF THE FLEMING STEEL DOOR
 AND FRAME UL FOLLOW-UP INFORMATION THAT WAS ATTACHED TO
 THE STORM PANEL SUBMITTAL.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2009-12-28 Cont ID  
Sent By rmcdouga Date 2009-12-28 Time 11:40 Rev Time 0.00
Received By rmcdouga Date 2009-12-28 Time 11:40 Sent To  
Notes
2009-12-28 12:24:37REVISION TO 09100241
  
 DENIED BY BUILDING
  
 1) THE REVISED PLANS DO NOT SHOW COMPLIANCE WITH
 ACCESSIBILITY REQUIREMENTS FOR FIXED SEATING AND
 TABLES, COUNTER-TOP HEIGHTS AND REQUIRED CLEAR FLOOR
 SPACE. SHOW COMPLIANCE WITH FBC 11-4.32, 4.33, 5.1 AND
 5.2.
  
 2) REVISE THE HANDRAIL DETAIL IN SECTION E ON SHEET
 A2.1 TO COMPLY WITH FBC 11-4.9.4(3) WHICH REQUIRES THE
 CLEAR SPACE BETWEEN HANDRAILS AND THE WALL TO BE
 1-1/2". THIS IS AN ABSOLUTE DIMENSION. IN THE DETAIL
 THIS MEASUREMENT IS SHOWN TO THE MOUNTING BRACKET
 FLANGE, NOT THE WALL.
  
 3) IN SECTION B ON SHEET A2.1 A PORTION OF THE TEXT HAS
 BEEN DELETED. PLEASE CORRECT.
  
 4) ON THE CEILING PLAN ON SHEET A3.1 THERE SHOULD BE AN
 ADDITIONAL DIRECTIONAL EXIT SIGN AT THE TOP OF THE
 STAIRS SHOWING THE DIRECTION OF EGRESS TO THE EXIT
 DOORS. FBC 1006.3.8
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2010-01-06 Cont ID  
Sent By btrobaug Date 2010-01-06 Time 11:30 Rev Time 0.00
Received By btrobaug Date 2010-01-06 Time 10:01 Sent To I
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2010-02-02 Cont ID  
Sent By mawillia Date 2010-02-02 Time 15:48 Rev Time 0.00
Received By mawillia Date 2010-02-02 Time 15:35 Sent To  
Notes
2010-02-02 15:42:22*****REVISION APPROVED*****
  
  
 REVISED PLAN SHEETS A2.1 AND A3.1 STAMPED, INITIALED,
 AND DATED.
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2009-12-29 Cont ID  
Sent By mawillia Date 2009-12-29 Time 13:07 Rev Time 0.00
Received By mawillia Date 2009-12-29 Time 12:55 Sent To  
Notes
2009-12-29 12:55:50*****PARTIAL APPROVAL, FIRE-STAMPING NEEDED*****
  
  
 REVISED PLAN SHEETS A2.1, A3.1, AND E2.01 TO BE
 FIRE-STAMPED WHEN THE OTHER TRADES' PLAN EXAMINER
 COMMENTS HAVE BEEN ADDRESSED.
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By jwitmer Date 2010-02-04 Time 08:53 Sent To  
Notes
2010-02-04 08:53:44INCOMING SENT TO R. MC DOUGAL

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2010-01-19 Cont ID  
Sent By shill Date 2010-01-19 Time 10:27 Rev Time 0.00
Received By shill Date 2010-01-19 Time 10:27 Sent To  
Notes
2010-01-19 10:27:42C17
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-12-14 Cont ID  
Sent By dpalmer Date 2009-01-06 Time 15:35 Rev Time 0.00
Received By btrobaug Date 2009-12-14 Time 15:35 Sent To PC
Notes
2010-01-06 11:33:33FAILED ARCHITECTURAL SHEETS IN HOLDING BIN UNDER "B",
 PASSED ELECTRICAL 7 PLUMBING SHEETS UP FRONT UNDER
 "B"./WRT.
2009-12-14 15:36:57C22

Review Stop P PLUMBING
Rev No 1 Status P Date 2010-01-05 Cont ID  
Sent By kstevens Date 2010-01-05 Time 13:47 Rev Time 0.00
Received By kstevens Date 2010-01-05 Time 13:47 Sent To  
Notes
2010-01-05 13:48:41REVISIONS OK -- SHTS P1.01, P2.01 & P2.02.

Review Stop Z ZONING
Rev No 1 Status N Date 2009-12-24 Cont ID  
Sent By aaponte Date 2009-12-24 Time 11:21 Rev Time 0.00
Received By aaponte Date 2009-12-24 Time 11:21 Sent To  
Notes
***NONE***