Plan Review Details - Permit 09120179
Plan Review Stops For Permit 09120179
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2009-12-08 Cont ID  
Sent By jgomez Date 2009-12-08 Time 16:31 Rev Time 0.00
Received By jgomez Date 2009-12-08 Time 16:31 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2009-12-08 Cont ID  
Sent By jgomez Date 2009-12-08 Time 14:50 Rev Time 0.00
Received By jgomez Date 2009-12-08 Time 14:31 Sent To PC
Notes
2009-12-08 15:14:05RESIDENTIAL (R3) REROOF, BUILDING REVIEW CHECKLIST.
 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS.
  
 1- ACCORDING TO SEC. R301 OF 2009 REVISIONS TO THE 2007
 FLORIDA RESIDENTIAL CODE, THIS BUILDING IS LOCATED ON
 EXPOSURE "C". FLORIDA PRODUCT APPROVAL FL717 SUBMITTED
 FOR THE ROOF TILE ADHESIVE DOESN'T PROVIDE THE REQUIRED
 ATTACHMENT RESISTANCE TO COMPLY WITH THE DESIGN
 PRESSURES OF SEC. R301 OF 2007 FLORIDA RESIDENTIAL
 CODE. NEED TO PROVIDE PRODUCT APPROVAL THAT MEETS THE
 CALCULATED DESIGN PRESSURES.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712