Plan Review Details - Permit 09110579
Plan Review Stops For Permit 09110579
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2010-01-21 Cont ID  
Sent By dpalmer Date 2010-01-21 Time 08:47 Rev Time 0.00
Received By dpalmer Date 2010-01-21 Time 08:47 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2010-01-13 Cont ID  
Sent By dpalmer Date 2010-01-13 Time 08:08 Rev Time 0.00
Received By dpalmer Date 2010-01-13 Time 08:08 Sent To  
Notes
2010-01-13 08:09:03** TEMP FAILED BASED ON ZONING COMMENTS. CAN NTO STAMP
 PLANS AT THIS TIME.
  
 1) NOTE: THERE ARE COMMENT FROM ZONING WHICH NEED TO BE
 ADDRESSED BEFORE PLANS CAN BE STAMPED. THE FIRST THREE
 SHEETS TO EACH SET CONTAINS MEASURMENTS AND SIZING NOT
 CONSISTENT WITHN ONE ANOTHER. ONE SET INDICATES ONE
 SIZE OR ELEVATION AND THE OTHER SET INDICATES A
 DIFFERENT SIZE OR ELEVATION.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2009-12-21 Cont ID  
Sent By shill Date 2009-12-21 Time 09:51 Rev Time 0.00
Received By shill Date 2009-12-21 Time 09:51 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2010-01-21 Cont ID  
Sent By dpalmer Date 2010-01-21 Time 09:13 Rev Time 0.00
Received By dpalmer Date 2010-01-21 Time 09:13 Sent To PC
Notes
2010-01-21 09:13:37PROCESSED AND STAMPED ALL SHEETS.

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2010-01-13 Cont ID  
Sent By dpalmer Date 2010-01-13 Time 08:03 Rev Time 0.00
Received By dpalmer Date 2010-01-13 Time 08:03 Sent To  
Notes
2010-01-13 08:08:03** TEMP FAILED.
  
 1) NOTE: ELECTRICAL REVIEW IS OK AND VALUE HAS BEEN
 INCREASED FOR PROJECT. FEE BALANCE DUE BEFORE ISSUANCE.
  
 2) NOTE: THE INCORRECT NEC IS STATED ON PLANS. PLANS
 SHOW 2005 WHEN THESE SHOULD BE 2008. ALL PERMIT
 APPLICATIONS AFTER OCT 1ST, 2009 ARE UNDER THE 2008
 NEC. THIS CAN BE REDLINED AND STAMPED ON SHEETS WHICH
 ARE NOT BE CORRECTED FOR OTHER COMMENTS.
  
 3) NOTE: THERE ARE COMMENT FROM ZONING WHICH NEED TO BE
 ADDRESSED BEFORE PLANS CAN BE STAMPED. THE FIRST THREE
 SHEETS TO EACH SET CONTAINS MEASURMENTS AND SIZING NOT
 CONSISTENT WITHN ONE ANOTHER. ONE SET INDICATES ONE
 SIZE OR ELEVATION AND THE OTHER SET INDICATES A
 DIFFERENT SIZE OR ELEVATION.
  
  
 IF THERE ARE ANY QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLANS EXAMINER II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2009-12-09 Cont ID  
Sent By dpalmer Date 2009-12-09 Time 09:48 Rev Time 0.00
Received By dpalmer Date 2009-12-09 Time 09:48 Sent To B
Notes
2009-12-09 09:49:01 
 ** DENIED **
  
 1) NOTE: PLEASE PROVIDE COPY OF CONTRACT FOR ALL NEW
 SIGNS. THE VALUE FOR THE LED SIGNS SUBMITTED IS LOW.
 FBC 108.3 REQUIRES THE VALUE TO INCLUDE ALL LABOR,
 EQUIPMENT, MATERIALS, DESIGN COST ETC EVEN IF ANY OF
 THESE ITEMS ARE OWNER SUPPLIED.
  
 2) NOTE: PLEASE SUPPLY SPECIFICATION CUT SHEETS FOR THE
 LED DRIVERS.
 PLEASE BE SURE LISTING BY A NRTL IS LISTED ON THE
 SHEETS.
 NEC 110.3
  
 3) NOTE: CITY PLACE MANAGMENT STAMP IS REQUIRED ON ALL
 PLANS.
  
  
 IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT
 TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO
 CONTACT THIS REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2010-01-20 Cont ID  
Sent By lmartine Date 2010-01-13 Time 11:08 Rev Time 0.00
Received By lmartine Date 2010-01-13 Time 11:07 Sent To  
Notes
2010-01-20 11:12:41*********************EXPEDITED*********************
 2ND RUN
 SENT TO ZONING ON 1/20/10

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2010-01-04 Cont ID  
Sent By shill Date 2010-01-04 Time 13:22 Rev Time 0.00
Received By shill Date 2010-01-04 Time 13:22 Sent To  
Notes
2010-01-12 15:57:21TO DP DESK 1/12/10
  
2010-01-04 13:23:10TO ZONING
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-12-21 Cont ID  
Sent By shill Date 2009-12-21 Time 09:51 Rev Time 0.00
Received By shill Date 2009-11-30 Time 14:24 Sent To Z
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status P Date 2010-01-20 Cont ID  
Sent By eschneid Date 2010-01-20 Time 16:06 Rev Time 0.33
Received By eschneid Date 2010-01-20 Time 16:06 Sent To E
Notes
2010-01-20 16:15:40CITYPLACE STAMP ON ONE SET OF PLANS. THIS IS SUFFICIENT
 TO ADDRESS ZONING COMMENT.

Review Stop Z ZONING
Rev No 2 Status F Date 2010-01-12 Cont ID  
Sent By eschneid Date 2010-01-12 Time 13:40 Rev Time 0.50
Received By eschneid Date 2010-01-12 Time 10:44 Sent To E
Notes
2010-01-12 13:41:20FAILED
  
 1) ONLY ONE COMPLETE SET OF REVISED PLANS WAS SUBMITTED
 WITH THE PERMIT RESUBMITTAL - THE TWO SETS OF PLANS
 HAVE DIFFERENT DIMENSIONS AND LAYOUT FOR THE CANOPY
 BROWS.
  
 2) ONE SET OF PLANS (THE SET WITH ALL PAGES HAVING THE
 CITYPLACE MANAGEMENT STAMP) SHOWS A DIFFERENT HEIGHT
 DIMENSION FOR THE SOUTH EAST CORNER OF THE BUILDING
 BETWEEN SHEETS 1 AND 2 (27 FEET VS. 28 FEET).
  
 3) REPEAT COMMENT: NOT ALL PLANS HAVE THE CITYPLACE
 MANAGEMENT STAMP.
  
 4) REPEAT COMMENT: THE CITYPLACE MASTER SIGN PLAN
 REQUIRES SIGN TEXT TO BE A MINIMUM OF 8 INCHES IN
 HEIGHT. THE HEIGHT OF THE SMALLEST LETTER ON THE MENU
 BOARD APPEARS TO BE LESS THAN 2 INCHES IN HEIGHT. A
 VARIANCE APPROVING THE HEIGHT OF THE MENU BOARD LETTERS
 IS REQUIRED.
  
 A COPY OF THESE COMMENTS HAS BEEN SENT TO CARLOS BERNAL
 AT CITYPLACE.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.
  

Review Stop Z ZONING
Rev No 1 Status F Date 2009-12-07 Cont ID  
Sent By shill Date 2009-12-21 Time 09:52 Rev Time 0.50
Received By eschneid Date 2009-12-07 Time 18:41 Sent To E
Notes
2009-12-07 19:20:44FAILED
  
 1) THE CITYPLACE MANAGEMENT STAMP IS REQUIRED ON THE
 PLANS.
  
 2) THE PCN LISTED FOR THIS PROPERTY IS INCORRECT.
  
 3) THIS IS NOT A DESIGNATED SIGN LOCATION IN THE
 CITYPLACE MASTER SIGN PLAN.
  
 4) THE CITYPLACE MASTER SIGN PLAN PROHIBITS INTERNALLY
 ILLUMINATED BOX SIGNS.
  
 5) THE CITYPLACE MASTER SIGN PLAN REQUIRES SIGN TEXT TO
 BE A MAXIMUM OF 12 INCHES IN HEIGHT. THE HEIGHT FOR THE
 LARGEST LETTERS WAS NOT PROVIDED ON THE PLANS (M AND S)
  
 6) THE CITYPLACE MASTER SIGN PLAN REQUIRES SIGN TEXT TO
 BE A MINIMUM OF 8 INCHES IN HEIGHT. THE HEIGHT OF THE
 SMALLEST LETTER WAS NOT PROVIDED ON THE PLANS (FRESH
 SEAFOOD ON MAIN SIGN & SMALLEST LETTERS ON THE MENU
 BOARD).
  
 7) THE CITYPLACE MASTER SIGN PLAN LIMITS THE SIZE OF
 THE BLADE SIGN PANEL TO 18 INCHES X 18 INCHES. THE
 BLADE SIGN EXCEEDS THIS DIMENSION (22 INCHES X 36
 INCHES).
  
 8) THE CITYPLACE MASTER SIGN PLAN DOES NOT ALLOW
 INTERNALLY ILLUMINATED BLADE SIGNS.
  
 9) THE CITYPLACE MASTER SIGN PLAN REQUIRES WRITTEN
 CONSENT FOR ACRYLIC MATERIAL.
  
 10) THE CITYPLACE MASTER SIGN PLAN DOES NOT ALLOW
 EXPOSED RACEWAYS. SHEETS 3 AND 4 CALL OUT A RACEWAY ON
 THE FRONT SIGN.
  
 11) THE CITYPLACE MASTER SIGN PLAN ALLOWS VARIANCES
 FROM THE PROVISIONS OF 3 THROUGH 9. PROVIDE A NOTARIZED
 LETTER FROM CITYPLACE THAT THEY HAVE GRANTED THE
 SPECIFIC VARIANCES NEEDED TO CONSTRUCT THE PROPOSED
 SIGN.
  
 A COPY OF THESE COMMENTS HAS BEEN SENT TO CARLOS BERNAL
 AT CITYPLACE.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.
  