Plan Review Stops For Permit 09110556 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2010-01-04 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2010-01-04 |
Time |
16:42 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2010-01-04 |
Time |
16:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2009-12-10 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-12-10 |
Time |
10:46 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-12-10 |
Time |
10:46 |
Sent To |
|
|
Notes |
2009-12-10 11:20:16 | 2007 FBC W/2009 REVISIONS | | ADD 2ND FLOOR LOFT | | | | DENIED BY BUILDING | | | | 1) THE ENGINEER LISTED IN THE TITLE BLOCK OF THE PLANS | | IS REQUIRED TO SIGN AND SEAL THE DRAWINGS. FS 471 | | | | 2) PROVIDE DETAILS OF THE GUARDS THAT ARE REQUIRED AT | | THE OPENING FROM THE LOFT TO THE LIVING ROOM BELOW. | | SHOW THAT IT COMPLIES WITH THE REQUIREMENTS OF FBC | | R312. | | | | 3) THE ENERGY CALCULATION FORM IS NOT REQUIRED BECAUSE | | RENOVATION IS LESS THAN 30 % OF ASSESSED VALUE OF THE | | STRUCTURE. NOTE: THE 2007 ENERGY GLITCH AMENDMENTS NO | | LONGER ALLOW METHOD C. THEREFORE, FORM 1100C-07 IS NO | | LONGER ACCEPTABLE. 13-101.2 | | | | 4) THE FLOOR PLAN ON SHEET 1 OF THE DRAWINGS SHOWS THE | | LOFT IN RELATION TO THE EXISTING FIRST FLOOR BELOW. | | SUBMIT TWO DRAWINGS OF THE LOFT FLOOR PLAN WITH THE | | SECOND FLOOR ROOMS AND WALLS FOR CLARITY. | | | | 5) UPDATE THE ELECTRIC CODE EDITION TO REFERENCE THE | | 2008 NEC. | | | | 6) SMOKE ALARMS ARE REQUIRED TO COMPLY WITH THE 2007 | | FBC R313.2.1. | | | | 7) IMPACT FEES MUST BE PAID TO PALM | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | COPY OF RECEIPT SUBMITTED TO CITY OF | | WEST PALM BEACH BUILDING DEPARTMENT, | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2009-12-30 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-12-30 |
Time |
17:02 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-12-30 |
Time |
17:02 |
Sent To |
B |
|
Notes |
2009-12-30 17:03:11 | LOW VOLTAGE UNDER SEPARATE PERMIT. MAY REFERENCE PLAN | | FOR CATV/PHONE |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2009-12-10 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-12-10 |
Time |
15:50 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-12-10 |
Time |
15:50 |
Sent To |
|
|
Notes |
2009-12-10 15:50:46 | | | ** DENIED ** | | | | | | ** SOME OF THE ITEMS BELOW COULD HAVE BEEN REDLINED | | HOWEVER NOT ALL. | | | | 1) NOTE: PLEASE SEE FLORIDA STATUTES 471.025, FAC | | 61G15-23.002 AS PLANS ARE REQUIRED TO BE SIGNED, DATED | | AND SEALED BY THE DESIGN PROFESSIONAL. | | | | 2) NOTE: PLEASE SEE R313.2.1. PLEASE SHOW LOCATIONS OF | | ALL EXISTING OR NEW SMOKE ALARMS MEETING CURRENT | | NFPA-72 11.5.1, 11.8.3 REQUIREMENTS. IF THE EXISTING | | SMOKE ALARMS DO NOT MEET CURRENT CODES, NEW SMOKE | | ALARMS WILL BE REQUIRED. PLAY ROOM VICINITY REQUIRED TO | | CONTAIN SMOKE ALARM. | | PLEASE SHOW ON PLANS. | | | | 3) NOTE: PLEASE INDICATE NEW RECEPTACLES PER 406.11, | | 2008 NEC. | | | | 4) NOTE: PLEASE SEE INDICATE NEW RECEPTACLES PER 210.12 | | OF THE 2008 NEC. | | | | 5) NOTE: PLEASE INDICATE THE DESIGN CODE RELEVANT. 2008 | | NFPA-70. PLANS INDICATE 2005. | | | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | CONTACT THIS REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2009-12-30 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2009-12-29 |
Time |
09:12 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2009-12-29 |
Time |
09:12 |
Sent To |
|
|
Notes |
2009-12-30 09:13:04 | GAVE TO DEWEY |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2009-12-10 |
Time |
|
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-11-30 |
Time |
14:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
N |
Date |
2010-01-04 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-12-10 |
Time |
11:31 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-12-10 |
Time |
11:31 |
Sent To |
|
|
Notes |
2009-12-10 11:32:23 | IMPACT FEE REVIEW REQUIRED. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2009-12-10 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-12-10 |
Time |
11:36 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-12-10 |
Time |
11:36 |
Sent To |
|
|
Notes |
2009-12-10 11:37:21 | NO MECHANICAL WORK INDICATED IN SCOPE OF WORK. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2009-12-02 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2009-12-02 |
Time |
17:46 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2009-12-02 |
Time |
17:46 |
Sent To |
|
|
Notes |
2009-12-02 17:46:41 | NO PLUMBING WORK INDICATED. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
2009-12-10 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-12-10 |
Time |
11:31 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-12-10 |
Time |
11:31 |
Sent To |
|
|
Notes |
|
|