Plan Review Details - Permit 09110398
Plan Review Stops For Permit 09110398
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2010-02-24 Cont ID  
Sent By jwitmer Date 2010-02-24 Time 08:15 Rev Time 0.77
Received By jwitmer Date 2010-02-24 Time 08:15 Sent To  
Notes
2010-02-24 08:49:01BUILDING PLAN REVIEW
 PERMIT: 09110398
 ADD: 2301 CENTRE PARK WEST DR SUITE# 100
 CONT: ANDERSON & MOORECONSTTRUCTION CORP
 TEL: (561) 662-1819
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 BUILDING APPROVED WITH EXCEPTION!
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S).
  
 PLANS DO NOT INDICATE IF THIS IS A FIRE SPRINKLERED
 BUILDING. SHEET A3 INDICATES DOOR TYPE "B" TO BE A 20
 MINUTE RATED DOOR. TENANT SEPERATION WALLS ARE REQUIRED
 TO BE 1 HOUR PER FBC BUILDING 708.1. TABLE 715.4
 REQUIRES 45MINUTE RATED DOORS FOR NON-SPRINKLERED
 BUILDING AND 20 MINUTE FOR FIRE SPRINKLERED BUILDINGS.
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
  
 PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE
 CUSTOMER SERVICE SURVEY AT:
 WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES
  
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2009-12-09 Cont ID  
Sent By jwitmer Date 2009-12-09 Time 09:18 Rev Time 0.00
Received By jwitmer Date 2009-12-09 Time 08:51 Sent To  
Notes
2009-12-09 09:23:06BUILDING PLAN REVIEW
 PERMIT: 09110398
 ADD: 2301 CENTRE PARK WEST DR SUITE# 100
 CONT: ANDERSON & MOORECONSTTRUCTION CORP
 TEL: (561) 662-1819
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
 DEC09/09
  
 1) PLANS INDICATE ONE TENANT SPACE TO BE SPLIT INTO (2)
 TENANT SPACES AND A COMMON AREA. THE PERMIT APPLICATION
 INDICATES WORK ONLY IN UNIT NUMBER 100 AND NOT THE
 COMMON AREAS. SHEET A-2 INDICATES ( DETAIL 1/ A3 A 1 HR
 DEMISING WALL) THE TENANT SEPARATION WALLS THAT ARE
 COMMON TO THE TENANT 100 AND COMMON AREAS TO BE A 1 HR
 RATED WALL BUT THE OTHER WALL COMMON TO TENANT 125 IS A
 DETAIL 3/ A3 ONLY RISING 6 INCHES ABOVE THE CEILING
 LINE. THIS WALL WILL ALSO NEED TO BE TIED TO THIS
 PERMIT SINCE THIS PERMIT IS CREATING THE COMMON AREA
 SPACE AND OTHER TENANCY. ANY OTHE WORK WITHIN TENANT
 SPACE 125 WILL NEED TO BE A SEPARATE PERMIT. PLEASE
 REVIEW SECTION 708.1 (7) TENANT SEPARATION WALLS FBC
 BUILDING.
  
 2) A2 ALSO INDICATES THE 2 DOORS THAT LEAD FROM THE
 COMMON AREAS INTO EACH TENANCY ARE A DOOR TYPE "B",
 PLEASE PROVIDE ADDITIONAL INFORMATION I DIDN'T SEE ANY
 DOOR SCHEDULE WITH FIRE RATINGS OPENING PROTECTIVE'S ,
 SECTION 715.4 AND TABLE 715.4.
  
 3) SHEET T PLEASE SEE OCCUPANT LOAD COUNT FOR BOTH
 SPACES FOR BUSINESS OCCPANCIES 100 SQ FT PER PERSON,
 WHEN THERE IS ADDITIONAL FOOTAGE 5,317= 54 OCCUPANTS
 THE PARTIAL SQUARE FOOTAGE IS ALWAYS ROLLED UP TO THE
 NEXT FULL OCCUPANT.
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
  
 PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE
 CUSTOMER SERVICE SURVEY AT:
 WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES
  
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  
2009-12-09 09:22:52TEST

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2009-11-30 Cont ID  
Sent By btrobaug Date 2009-11-30 Time 11:23 Rev Time 0.00
Received By btrobaug Date 2009-11-30 Time 11:05 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2009-12-07 Cont ID  
Sent By mawillia Date 2009-12-07 Time 10:23 Rev Time 0.00
Received By mawillia Date 2009-12-07 Time 09:48 Sent To  
Notes
2009-12-07 10:23:08*****APPROVED*****
  
  
 PLAN SHEETS A-1, A-4, AND E-3 WERE STAMPED, INITIALED,
 AND DATED.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2010-02-16 Cont ID  
Sent By lmartine Date 2010-02-11 Time 16:04 Rev Time 0.00
Received By lmartine Date 2010-02-11 Time 16:03 Sent To  
Notes
2010-02-16 16:04:28B--1

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-12-14 Cont ID  
Sent By hmoser Date 2009-12-14 Time 11:18 Rev Time 0.00
Received By hmoser Date 2009-11-17 Time 13:57 Sent To  
Notes
2009-11-17 14:03:35B3

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2010-02-24 Cont ID  
Sent By hmoser Date 2010-02-24 Time 13:49 Rev Time 0.00
Received By hmoser Date 2010-02-24 Time 13:18 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2009-12-14 Cont ID  
Sent By hmoser Date 2009-12-14 Time 11:07 Rev Time 0.00
Received By hmoser Date 2009-12-14 Time 10:12 Sent To  
Notes
2009-12-14 11:14:50MECHANICAL PLANS DENIED .
 PLEASE PROVIED DUCT SIZES ON ALL NEW DUCT WORK .
 PLEASE PROVIED THE SIZE OF OF AHU # 7 .
 PLAN REVIEW BY HAROLD MOSER 561-805-6732

Review Stop P PLUMBING
Rev No 1 Status N Date 2009-11-30 Cont ID  
Sent By kstevens Date 2009-11-30 Time 16:16 Rev Time 0.00
Received By kstevens Date 2009-11-30 Time 16:16 Sent To  
Notes
2009-11-30 16:16:58NO PLUMBING WORK INDICATED ON PLANS.

Review Stop Z ZONING
Rev No 1 Status P Date 2009-11-25 Cont ID  
Sent By jroach Date 2009-11-25 Time 13:11 Rev Time 0.00
Received By jroach Date 2009-11-25 Time 13:11 Sent To  
Notes
***NONE***