Plan Review Stops For Permit 09110210 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2009-12-07 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-12-07 |
Time |
11:09 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-12-07 |
Time |
11:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2009-11-30 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-11-30 |
Time |
10:36 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-11-30 |
Time |
10:36 |
Sent To |
|
|
Notes |
2009-11-30 10:40:13 | DENIED BY BUILDING | | | | 1) THE EXISTING FENCE IS REQUIRED TO COMPLY WITH THE | | BARRIER REQUIREMENTS OF FBC R4101.17. SPECIFY THIS ON | | THE PLANS. | | | | 2) THE ALARMS ON THE HOUSE ARE REQUIRED TOP COMPLY WITH | | FBC R4101.17.1.9. SPECIFY THIS ON THE PLANS. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2009-12-07 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-12-07 |
Time |
11:14 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-12-07 |
Time |
11:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2009-11-30 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-11-30 |
Time |
10:40 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-11-30 |
Time |
10:40 |
Sent To |
|
|
Notes |
2009-11-30 10:49:41 | DENIED BY ELECTRICAL | | | | 1) SHOW COMPLIANCE WITH 2008 NEC 680.26 (B) (2) FOR | | EQUIPOTENTIAL BONDING OF PERIMETER SURFACES. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2009-11-30 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-11-30 |
Time |
10:40 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-11-17 |
Time |
14:28 |
Sent To |
|
|
Notes |
2009-11-17 14:27:35 | TO RES SWIMMING POOL BOX | | | 2009-11-09 16:40:46 | TO ZONING | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2009-12-07 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-12-07 |
Time |
11:14 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-12-07 |
Time |
11:14 |
Sent To |
|
|
Notes |
2009-12-07 11:14:34 | CALCULATONS SHOWING THAT WATER VELOCITY IN POOL | | PRESSURE PIPING DOES NOT EXCEED 10 FT/SEC PER FBC R | | 4101.6.3 TO BE PROVIDED TO PLUMBING INSPECTOR. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2009-11-30 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-11-30 |
Time |
09:29 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-11-30 |
Time |
09:29 |
Sent To |
|
|
Notes |
2009-11-30 10:35:34 | 2007 FBC W/2009 REVISIONS | | | | | | DENIED BY PLUMBING | | | | 1) SUBMIT TOTAL DYNAMIC HEAD CALCULATIONS. FBC | | R4101.6.3 | | | | 2) PROVIDE A PIPING DIAGRAM WITH ALL PIPE SIZES | | SPECIFIED. FBC R4101.6 | | | | 3) SPECIFY THE WATER VELOCITY IN FEET PER SECOND FOR | | THE FOR THE SUCTION AND SUPPLY LINES. FBC R4101.6.3 | | | | 4) SPECIFY THE MAXIMUM FLOW RATE OF THE PUMP IN GALLONS | | PER MINUTE FOR THE TDH OF THE SYSTEM BEING INSTALLED. | | SUBMIT THE SPECIFICATIONS AND FLOW CHART FOR THE PUMP | | THAT WILL BE USED. FBC R4101.7 | | | | 5) THE PUMP CURVE CHART SUBMITTED HAS A 3/4 HP PUMP | | INDICATED ON IT AND THE PLANS SPECIFY A 2 HP PUMP. | | PLEASE CORRECT. | | | | 6) THE POOL HEATER IS REQUIRED BY FBC R4101.14.2 TO | | HAVE A PERMANENT BY-PASS OR ANTI-SIPHON DEVICE. SHOW | | COMPLIANCE. | | | | 7) THE PIPING DIAGRAM ON SHEET 2 SHOWS TWO MAIN DRAINS | | FOR THE POOL AND THE SPA. THE DRAWING ON SHEET 1 SHOWS | | CHANNEL DRAINS. PLEASE COORDINATE DRAWINGS. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2009-11-16 |
|
|
Cont ID |
|
Sent By |
kdfreema |
Date |
2009-11-16 |
Time |
14:33 |
Rev Time |
0.00 |
Received By |
kdfreema |
Date |
2009-11-16 |
Time |
14:33 |
Sent To |
|
|
Notes |
2009-11-16 14:33:36 | POOL EQUIPMENT MUST BE SET BACK A MINIMUM OF FOUR FEET | | FROM THE SIDE PROPERTY LINE. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2009-11-13 |
|
|
Cont ID |
|
Sent By |
kdfreema |
Date |
2009-11-13 |
Time |
08:28 |
Rev Time |
0.00 |
Received By |
kdfreema |
Date |
2009-11-13 |
Time |
08:28 |
Sent To |
|
|
Notes |
2009-11-13 08:30:32 | ***FAILED*** | | | | 1. PLEASE PROVIDE THE PROPOSED SETBACKS FOR THE POOL | | EQUIPMENT. NOTE THAT IT MAY NOT BE CLOSER THAN FOUR | | FEET TO THE PROPERTY LINE. | | | | PLEASE CONTACT KELLY FREEMAN, GIS PLANNER, AT | | 561-822-1458 OR [email protected] WITH QUESTIONS. |
|
|