Plan Review Details - Permit 09110177
Plan Review Stops For Permit 09110177
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2010-04-22 Cont ID  
Sent By rmcdouga Date 2010-04-22 Time 10:44 Rev Time 0.00
Received By rmcdouga Date 2010-04-22 Time 10:44 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2010-03-23 Cont ID  
Sent By rmcdouga Date 2010-03-23 Time 16:09 Rev Time 0.00
Received By rmcdouga Date 2010-03-23 Time 16:09 Sent To  
Notes
2010-03-23 16:18:302007 FBC W/2009 REVISIONS
 NEW SFR
 FLOOD ZONE A5
  
 DENIED BY BUILDING
  
 1) SUBMIT TWO COPIES OF PRODUCT APPROVALS THAT HAVE
 BEEN REVIEWED AND APPROVED IN WRITING BY THE DESIGNER
 OF RECORD FOR THE COMPONENTS AND CLADDING AS REQUIRED
 BY DCA RULE 9B-72 AND CITY AMENDMENTS.
  
 2) THE ENERGY CALCULATIONS ARE REQUIRED TO BE SIGNED
 AND DATED BY THE PREPARER. FBC 13-600
  
 3) THE ENERGY CALCULATIONS SPECIFY A 60 GALLON GAS
 WATER HEATER AND THE PLANS SHOW AN 80 GALLON ONE.
 PLEASE CORRECT.
  
 4) SHOW ON THE SITE PLAN A-1 THAT THE SURFACE DRAINAGE
 REQUIREMENTS OF FBC R401.3 WILL BE MET AND THAT THE
 SURFACE WATER WILL BE DIRECTED TO APPROVED COLLECTIONS
 POINTS AND NOT ONTO ADJACENT PROPERTIES.
  
 5) PLEASE UPDATE THE REFERENCES ON A-1 TO ACI 530, ACI
 530.1, ACI 318 AND ACI 301 TO THE 2005 EDITIONS AS THE
 STANDARDS SPECIFIED IN CHAPTER 43 OF THE 2007 FBC
 RESIDENTIAL.
  
 6) PLEASE UPDATE THE STAIR NOTES ON SHEET A-11 FROM
 2004 TO THE 2007 FBCR. REVISE NOTE #1 TO R311.5.3.1.
  
 7) REVISE THE GUARDRAIL NOTE 1 ON A-11 FROM NOT LESS
 THAN 42" TO NOT LESS THAN 34" WHEN MEASURED VERTICALLY
 FROM THE TREAD NOSINGS PER FBC R312.1.
  
 8) THE LIVE LOAD NOTES FOR THE GUARDRAILS AND HANDRAILS
 IN THE CHART ON A-11 WERE NOT GIVEN. SEE TABLE R301.5
  
 9) ON A-10 THE DRAFT STOPPING NOTE CODE SECTION IS FROM
 THE 2004 HVHZ. PLEASE REVISE TO THE 2007 FBC R602.1.2
 WHICH REQUIRES FIREBLOCKING AT THE TOP AND BOTTOM OF
 STAIR RUNS.
  
 10) SUBMIT THE SPECIFICATIONS AND LISTING FOR THE BBQ
 AND HOOD LOCATED ON THE LANAI OR INDICATE THAT THEY
 WILL BE APPLIED FOR UNDER A SEPARATE PERMIT.
  
 11) SPECIFY CEILING MATERIAL THAT WILL BE INSTALLED IN
 THE LANAI AND THE COVERED PORCH ABOVE IT.
  
 12) SHOW COMPLIANCE WITH FBC R309.2 FOR GARAGE
 SEPARATION. 5/8" TYPE X GYPSUM BOARD IS REQUIRED
 BETWEEN GARAGES AND HABITABLE ROOMS ABOVE.
  
 13) ON A-10 THE BUILDING CROSS SECTION SHOWS A CONCRETE
 FLOOR AT THE COVERED PORCH ABOVE THE LANAI. SHEET S-2
 AND 1 ON SD3 SHOWS WOOD TRUSSES. PLEASE CLARIFY.
  
 14) THE H-35 SINGLE HUNG WINDOWS SPECIFIED AT TWO OF
 THE SECOND FLOOR BEDROOMS, DO NOT HAVE THE REQUIRED 5.7
 SQFT MINIMUM NET CLEAR OPENING REQUIRED BY FBC R310.1.1
 FOR EMERGENCY ESCAPE AND RESCUE OPENINGS. (WINDOWS R-1
 THRU R-4 AND S-1) REVISE PLANS.
  
 15) ON SHEETS S-1 THE FOUNDATION PLAN AND S-2 THE FLOOR
 FRAMING PLAN THE COLUMN AT THE LANAI THAT SUPPORTS THE
 BEAMS B111 AND B112 IS NOT SPECIFIED. PLEASE PROVIDE
 DETAILS FOR THIS COLUMN.
  
 16) THE STRUCTURE IS LOCATED IN AN A5 FLOOD ZONE THE
 MINIMUM ELEVATION IS REQUIRED TO BE 7' 6" ABOVE BASE
 FLOOD ELEVATION. CITY ORDINANCES. AN ELEVATION
 CERTIFICATE WILL BE REQUIRED BEFORE FINAL INSPECTION.
  
 17) SUBMIT 2 COPIES OF PRODUCT APPROVALS FOR THE
 STRUCTURAL MULLIONS AND FIXED WINDOWS AS REQUIRED BY
 DCA RULE 9B-72.
  
 18) THE FRONT DOOR IS SPECIFIED ON THE PLAN AS BEING
 3'-6" X 8'-0" WITH A SIDE-LITE. THE PRODUCT APPROVAL
 THAT WAS SUBMITTED FOR THE FRENCH DOORS HAS A MAXIMUM
 SINGLE DOOR WIDTH OF 3 FEET. PLEASE CORRECT.
  
 19) SUBMIT TWO COPIES OF CURRENT (2007 FBC) FLORIDA
 PRODUCT APPROVALS OR MIAMI-DADE NOAS FOR THE ANKMAR
 OVERHEAD GARAGE DOOR. THE INFORMATION SUBMITTED IS NOT
 ACCEPTABLE.
  
 20) THE PRODUCT APPROVALS FOR THE PGT SH WINDOWS IS FOR
 SMALL MISSILE IMPACT ONLY. THE WINDOWS ARE REQUIRED TO
 BE APPROVED FOR LARGE MISSILE IMPACT PER FBC
 R301.2.1.2.
  
 21) SPECIFY THE ROOF TILE ATTACHMENT THAT WILL BE USED
 FOR THE MONIER "S" TILE. THE METHOD SELECTED MUST BE
 CAPABLE OF RESISTING THE OVERTURN MOMENT FOR A 140 MPH
 EXPOSURE C LOCATION.
  
 NOTE: BEFORE A PERMIT TO CONSTRUCT CAN BE
 ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE PLANS MUST BE
 STAMPED AND THE RECEIPT ATTACHED TO THE
 APPLICATION. 233-5025
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE COMMENTS
 INDICATING HOW THEY HAVE BEEN ADDRESSED.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2009-12-08 Cont ID  
Sent By rmcdouga Date 2009-12-08 Time 10:27 Rev Time 0.00
Received By rmcdouga Date 2009-12-03 Time 06:51 Sent To  
Notes
2009-12-08 12:00:032007 FBC W/2009 REVISIONS
 NEW SFR
  
 DENIED BY BUILDING
  
 1) SUBMIT TWO COPIES OF PRODUCT APPROVALS THAT HAVE
 BEEN REVIEWED AND APPROVED IN WRITING BY THE DESIGNER
 OF RECORD FOR THE COMPONENTS AND CLADDING AS REQUIRED
 BY DCA RULE 9B-72 AND CITY AMENDMENTS.
  
 2) SUBMIT TWO COPIES OF ENERGY CALCULATIONS AS REQUIRED
 BY FBC CHAPTER 13.
  
 3) SUBMIT TWO COPIES OF A PROPERTY SURVEY.
  
 4) SHOW ON THE SITE PLAN A-1 THAT THE SURFACE DRAINAGE
 REQUIREMENTS OF FBC R401.3 WILL BE MET AND THAT THE
 SURFACE WATER WILL BE DIRECTED TO APPROVED COLLECTIONS
 POINTS AND NOT ONTO ADJACENT PROPERTIES.
  
 5) PLEASE UPDATE THE REFERENCES ON A-1 TO ACI 530, ACI
 530.1, ACI 318 AND ACI 301 TO THE 2005 EDITIONS AS THE
 STANDARDS SPECIFIED IN CHAPTER 43 OF THE 2007 FBC
 RESIDENTIAL.
  
 6) PLEASE UPDATE THE STAIR NOTES ON SHEET A-11 FROM
 2004 TO THE 2007 FBCR. REVISE NOTE #1 TO R311.5.3.1.
  
 7) REVISE THE GUARDRAIL NOTE 1 ON A-11 FROM NOT LESS
 THAN 42" TO NOT LESS THAN 34" WHEN MEASURED VERTICALLY
 FROM THE TREAD NOSINGS PER FBC R312.1.
  
 8) THE LIVE LOAD NOTES FOR THE GUARDRAILS AND HANDRAILS
 IN THE CHART ON A-11 WERE NOT GIVEN. SEE TABLE R301.5
  
 9) ON A-10 THE DRAFT STOPPING NOTE CODE SECTION IS FROM
 THE 2004 HVHZ. PLEASE REVISE TO THE 2007 FBC R602.1.2
 WHICH REQUIRES FIREBLOCKING AT THE TOP AND BOTTOM OF
 STAIR RUNS.
  
 10) SPECIFY THE LOCATIONS AND MATERIAL THAT WILL BE
 USED FOR THE DRAFTSTOPPING AT THE FLOOR/CEILING
 ASSEMBLY THAT WILL SEPARATE IT INTO AREAS LESS THAN
 1000 SQFT AS REQUIRED BY FBC R502.1.2.
  
 11) SUBMIT THE SPECIFICATIONS AND LISTING FOR THE BBQ
 AND HOOD LOCATED ON THE LANAI OR INDICATE THAT THEY
 WILL BE APPLIED FOR UNDER A SEPARATE PERMIT.
  
 12) SPECIFY CEILING MATERIAL THAT WILL BE INSTALLED IN
 THE LANAI AND THE COVERED PORCH ABOVE IT.
  
 13) SHOW COMPLIANCE WITH FBC R309.2 FOR GARAGE
 SEPARATION. 5/8" TYPE X GYPSUM BOARD IS REQUIRED
 BETWEEN GARAGES AND HABITABLE ROOMS ABOVE.
  
 14) ON A-10 THE BUILDING CROSS SECTION SHOWS A CONCRETE
 FLOOR AT THE COVERED PORCH ABOVE THE LANAI. SHEET S-2
 AND 1 ON SD3 SHOWS WOOD TRUSSES. PLEASE CLARIFY.
  
 15) ON SHEET S-2 THE FRONT BALCONY IS NOT SHOWN ON THE
 FLOOR PLAN. PROVIDE STRUCTURAL DETAILS AND DIMENSIONS
 FOR THIS CONCRETE BALCONY.
  
 16) ON SHEET S-3 REVISE THE ROOF SHEATHING FASTENING TO
 8D RING SHANK NAILS TO CORRESPOND WITH SHEET SD1 AND
 FBC R803.2.3.1.
  
 17) ON SHEET S-3 UPDATE THE WIND LOAD TABLE TO
 REFERENCE ASCE 7-05 AS SPECIFIED IN FBC R CHAPTER 43.
  
 18) PLEASE CORRECT DETAIL 10 ON SD2 WHICH HAS THE TITLE
 ON TOP OF THE NOTES.
  
 19) THE H-35 SINGLE HUNG WINDOWS SPECIFIED AT TWO OF
 THE SECOND FLOOR BEDROOMS, DO NOT HAVE THE REQUIRED 5.7
 SQFT MINIMUM NET CLEAR OPENING REQUIRED BY FBC R310.1.1
 FOR EMERGENCY ESCAPE AND RESCUE OPENINGS. (WINDOWS R-1
 THRU R-4 AND S-1)
  
 20) ON S-2 THE TRUSS IDS IN THE CONNECTOR SCHEDULE ARE
 LISTED WITHOUT THE "0" BETWEEN THE NUMBERS THAT THE
 FRAMING PLAN LISTS. FOR EXAMPLE THE FRAMING PLAN LISTS
 S01 AND THE SCHEDULE HAS S1. IN ORDER TO AVOID
 CONFUSION, PLEASE COORDINATE THE ID TAGS.
  
 21) ON SHEETS S-1 THE FOUNDATION PLAN AND S-2 THE FLOOR
 FRAMING PLAN THE COLUMN AT THE LANAI THAT SUPPORTS THE
 BEAMS B111 AND B112 ARE NOT SPECIFIED. PLEASE PROVIDE
 DETAILS FOR THIS COLUMN.
  
 22) PLEASE SPECIFY THE DESIGN PRESSURES FOR THE
 EXTERIOR DOORS AND WINDOWS IN THE SCHEDULE ON SHEET
 A-11. FBC R301.2.1
  
 23) PLEASE PROVIDE A WRITTEN RESPONSE TO THE COMMENTS
 INDICATING HOW THEY HAVE BEEN ADDRESSED.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2010-03-16 Cont ID  
Sent By btrobaug Date 2010-03-16 Time 11:49 Rev Time 0.00
Received By btrobaug Date 2010-03-16 Time 11:43 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2009-11-24 Cont ID  
Sent By btrobaug Date 2009-11-24 Time 13:00 Rev Time 0.00
Received By btrobaug Date 2009-11-24 Time 10:29 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2010-03-30 Cont ID  
Sent By shill Date 2010-03-30 Time 15:07 Rev Time 0.00
Received By shill Date 2010-03-30 Time 15:07 Sent To  
Notes
2010-03-30 15:09:03R 12
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-12-08 Cont ID  
Sent By rmcdouga Date 2009-12-08 Time 13:58 Rev Time 0.00
Received By rmcdouga Date 2009-11-10 Time 09:24 Sent To  
Notes
2009-11-10 09:27:28R19
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2010-05-03 Cont ID  
Sent By rmcdouga Date 2010-05-03 Time 14:21 Rev Time 0.00
Received By rmcdouga Date 2010-05-03 Time 14:21 Sent To  
Notes
2010-05-03 14:22:13RETURNED STAMPED PLANS AND RECEIPT FOR IMPACT FEES.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2009-12-02 Cont ID  
Sent By rmcdouga Date 2009-12-02 Time 11:18 Rev Time 0.00
Received By rmcdouga Date 2009-12-02 Time 11:19 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2010-04-22 Cont ID  
Sent By rmcdouga Date 2010-04-22 Time 16:27 Rev Time 0.00
Received By rmcdouga Date 2010-04-22 Time 16:27 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2010-03-16 Cont ID  
Sent By hmoser Date 2010-03-16 Time 09:38 Rev Time 0.00
Received By hmoser Date 2010-03-16 Time 09:09 Sent To  
Notes
2010-03-16 09:44:00PLANS DENIED
 1) PLEASE PROVIDE AN EQUIPMENT SCHEDULE ON THE PLANS .
 2) PLEASE REFER TO SECTION M1602.4 2007 RESIDENTIAL
 CODE .
 PLAN REVIEW BY HAROLD MOSER 561-805-6732

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2009-12-02 Cont ID  
Sent By hmoser Date 2009-12-02 Time 10:41 Rev Time 0.00
Received By hmoser Date 2009-12-02 Time 10:23 Sent To  
Notes
2009-12-02 10:51:13THERE ARE NO MECHANICAL PLANS IN THE PACKAGE . PLEASE
 HAVE MECHANICAL CONTRACTOR PROVIDE PLANS AND ENERGY
 CALLS. WITH THE APPLICATION.
 PLAN REVIEW BY HAROLD MOSER 561-805-6732

Review Stop P PLUMBING
Rev No 2 Status P Date 2010-04-22 Cont ID  
Sent By rmcdouga Date 2010-04-22 Time 11:04 Rev Time 0.00
Received By rmcdouga Date 2010-04-22 Time 11:04 Sent To  
Notes
2010-04-22 11:05:48RESTAMP NEW PLANS/ THE SAME PROVISO ITEMS FROM FIRST
 REVIEW ARE REQUIRED

Review Stop P PLUMBING
Rev No 1 Status P Date 2009-11-10 Cont ID  
Sent By kstevens Date 2009-11-10 Time 11:01 Rev Time 0.00
Received By kstevens Date 2009-11-10 Time 11:01 Sent To  
Notes
2009-11-10 11:10:15PASSED/PROVISO:
  
 MINIMUM 2-1/2" PIPE REQUIRED UPSTREAM OF THE W/C IN THE
 MASTER BATH.
 A SEPARATE GAS PERMIT WITH PLANS IS REQUIRED.
 A SEPARATE IRRIGATION PERMIT IS REQUIRED.
 A SEPARATE POOL PERMIT IS REQUIRED.

Review Stop Z ZONING
Rev No 3 Status P Date 2010-04-08 Cont ID  
Sent By eschneid Date 2010-04-05 Time 13:04 Rev Time 1.25
Received By eschneid Date 2010-04-05 Time 13:04 Sent To  
Notes
2010-04-05 13:15:24PASSED
  
 1) PROVISO: THE ROOF OVERHAND SHALL NOT INTRUDE MORE
 THAN THREE FEET INTO A SETBACK. PLEASE NOTE THAT THE
 OVERHANG IS MEASURED FROM THE WALL TO THE FURTHEST
 POINT OF THE OVERHANG - THIS DIMENSION IS INCORRECTLY
 SHOWN ON ONE OF THE SECTION DRAWINGS.
  
 2) PROVISO: THE BUILDING HEIGHT MAY NOT EXCEED 30 FEET
 AS DEFINED BY THE CITY OF WEST PALM BEACH ZONING AND
 LAND DEVELOPMENT REGULATIONS - BUILDING, HEIGHT OF,
 MEANS THE VERTICAL DISTANCE FROM THE MEAN GRADE OF A
 LOT AT THE FRONTAGE OF THE BUILDING TO THE HIGHEST
 POINT OF THE TOP OF THE STRUCTURE OF A FLAT ROOF, OR TO
 THE DECK LINE OF A MANSARD ROOF, OR TO THE MID-HEIGHT
 LEVEL BETWEEN EAVES AND RIDGE FOR GABLE, HIP, AND
 GAMBREL ROOFS.
  
 3) NOTE: A SEPARATE IRRIGATION PERMIT IS REQUIRED.
  
 4) NOTE: THE PROPOSED DRIVEWAY AND POOL REQUIRE
 SEPARATE PERMITS.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.

Review Stop Z ZONING
Rev No 2 Status F Date 2010-03-18 Cont ID  
Sent By eschneid Date 2010-03-18 Time 14:44 Rev Time 0.50
Received By eschneid Date 2010-03-18 Time 14:44 Sent To  
Notes
2010-03-18 14:49:50FAILED
  
 NOTE: THE SUBMITTAL OF THE REQUESTED INFORMATION MAY
 GENERATE ADDITIONAL COMMENTS.
  
 RESPOND TO COMMENTS IN WRITING.
  
 1) REPEAT COMMENT: THE SF7 ZONING DISTRICT REQUIRES A
 25 FOOT FRONT SETBACK. THE SITE PLAN SHOWS THE PROPOSED
 HOUSE ENCROACHING INTO THE 25 FOOT SETBACK.
  
 2) REPEAT COMMENT: INDICATE SETBACK DIMENSIONS FROM
 PROPOSED A/C EQUIPMENT, INCLUDING THE PAD, TO ALL
 PROPERTY LINES ON THE SITE PLAN. PURSUANT TO SECTION
 94-305(B)(4) OF THE CITY OF WEST PALM BEACH ZONING AND
 LAND DEVELOPMENT REGULATIONS : MECHANICAL EQUIPMENT MAY
 NOT PROJECT MORE THAN 4 FEET INTO A REQUIRED SETBACK.
  
 3) REPEAT COMMENT: THE ROOF OVERHAND SHALL NOT INTRUDE
 MORE THAN THREE FEET INTO A SETBACK. PLEASE PROVIDE ALL
 OVERHANG DIMENSIONS ON THE ELEVATIONS. PLEASE NOTE THAT
 THE OVERHANG IS MEASURED FROM THE WALL TO THE FURTHEST
 POINT OF THE OVERHANG - THIS IS INCORRECTLY SHOWN ON
 ONE OF THE SECTION DRAWINGS.
  
 4) REPEAT COMMENT: PLEASE PROVIDE THE BUILDING HEIGHT
 ON THE ELEVATIONS AS DEFINED BY THE CITY OF WEST PALM
 BEACH ZONING AND LAND DEVELOPMENT REGULATIONS -
 BUILDING, HEIGHT OF, MEANS THE VERTICAL DISTANCE FROM
 THE MEAN GRADE OF A LOT AT THE FRONTAGE OF THE BUILDING
 TO THE HIGHEST POINT OF THE TOP OF THE STRUCTURE OF A
 FLAT ROOF, OR TO THE DECK LINE OF A MANSARD ROOF, OR TO
 THE MID-HEIGHT LEVEL BETWEEN EAVES AND RIDGE FOR GABLE,
 HIP, AND GAMBREL ROOFS.
  
 5) NOTE: A SEPARATE LANDSCAPE PERMIT IS REQUIRED WHICH
 INCLUDES THE LANDSCAPE PLAN. THE LANDSCAPE PLAN SHALL
 SHOW CONFORMANCE WITH SECTION 94-442(B)(2)A OF THE CITY
 OF WEST PALM BEACH ZONING AND LAND DEVELOPMENT
 REGULATIONS.
  
 6) NOTE: THE FRONT HEDGE APPEARS TO BE LOCATED WITHIN
 THE RIGHT-OF-WAY. THIS IS NOT PERMITTED.
  
 7) NOTE: THE PROPOSED DRIVEWAY AND POOL REQUIRE
 SEPARATE PERMITS.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.
  
  

Review Stop Z ZONING
Rev No 1 Status F Date 2009-11-16 Cont ID  
Sent By eschneid Date 2009-11-16 Time 17:42 Rev Time 0.75
Received By eschneid Date 2009-11-16 Time 17:42 Sent To  
Notes
2009-11-16 18:10:30FAILED
  
 NOTE: THE SUBMITTAL OF THE REQUESTED INFORMATION MAY
 GENERATE ADDITIONAL COMMENTS.
  
 RESPOND TO COMMENTS IN WRITING.
  
 1) THE SF7 ZONING DISTRICT REQUIRES A 25 FOOT FRONT
 SETBACK. THE PROPOSED HOUSE ENCROACHES INTO THE 25 FOOT
 SETBACK.
  
 2) INDICATE SETBACK DIMENSIONS FROM PROPOSED A/C
 EQUIPMENT, INCLUDING THE PAD, TO ALL PROPERTY LINES.
 PURSUANT TO SECTION 94-305(B)(4) OF THE CITY OF WEST
 PALM BEACH ZONING AND LAND DEVELOPMENT REGULATIONS :
 MECHANICAL EQUIPMENT MAY NOT PROJECT MORE THAN 4 FEET
 INTO A REQUIRED SETBACK.
  
 3) THE ROOF OVERHAND SHALL NOT INTRUDE MORE THAN THREE
 FEET INTO A SETBACK. PLEASE PROVIDE ALL OVERHANG
 DIMENSIONS ON THE ELEVATIONS. PLEASE NOTE THAT THE
 OVERHANG IS MEASURED FROM THE WALL TO THE FURTHEST
 POINT OF THE OVERHANG - THIS IS INCORRECTLY SHOWN ON
 ONE OF THE SECTION DRAWINGS.
  
 4) PLEASE PROVIDE THE BUILDING HEIGHT ON THE ELEVATIONS
 AS DEFINED BY THE CITY OF WEST PALM BEACH ZONING AND
 LAND DEVELOPMENT REGULATIONS - BUILDING, HEIGHT OF,
 MEANS THE VERTICAL DISTANCE FROM THE MEAN GRADE OF A
 LOT AT THE FRONTAGE OF THE BUILDING TO THE HIGHEST
 POINT OF THE TOP OF THE STRUCTURE OF A FLAT ROOF, OR TO
 THE DECK LINE OF A MANSARD ROOF, OR TO THE MID-HEIGHT
 LEVEL BETWEEN EAVES AND RIDGE FOR GABLE, HIP, AND
 GAMBREL ROOFS.
  
 5) PLEASE INDICATE SQUARE FOOTAGE OF THE LANDSCAPE IN
 THE FRONT YARD. PLEASE NOTE THAT A MINIMUM OF 1,000
 SQUARE FEET OF THE FRONT YARD AREA MUST BE LANDSCAPED.
  
 6) A SEPARATE LANDSCAPE PERMIT IS REQUIRED WHICH
 INCLUDES THE LANDSCAPE PLAN. THE LANDSCAPE PLAN SHALL
 SHOW CONFORMANCE WITH SECTION 94-442(B)(2)A OF THE CITY
 OF WEST PALM BEACH ZONING AND LAND DEVELOPMENT
 REGULATIONS. A TABLE SHOWING ALL LANDSCAPE TYPE AND
 SIZE IS REQUIRED.
  
 7) THE PROPOSED DRIVEWAY REQUIRES A SEPARATE PERMIT.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.
  
  