Plan Review Details - Permit 09100223
Plan Review Stops For Permit 09100223 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2009-10-19 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2009-10-19 |
Time |
12:26 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2009-10-19 |
Time |
12:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2009-10-15 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2009-10-15 |
Time |
13:40 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2009-10-15 |
Time |
13:40 |
Sent To |
PC |
|
Notes |
2009-10-15 14:03:13 | RESIDENTIAL (R3) REROOF, BUILDING REVIEW SECOND | | CHECKLIST. | | 2007 FL. RESIDENTIAL CODE WITH 2009 REVISIONS. | | | | 1- ENGINEER NEEDS TO REVISE THE RAS 117 CALCULATIONS. | | ACCORDING TO SEC. R301.2.1.4.3 OF 2009 REVISIONS TO THE | | 2007 FLORIDA RESIDENTIAL CODE THIS BUILDING IS LOCATED | | ON EXPOSURE "C", NOT "B". THIS WAS NOTED ON THE FIRST | | CHECKLIST. | | | | 2- ENGINEER LETTER SPECIFIES APPROVED ASSEMBLY ON SHEET | | #16 WITH OPTION #1 FOR BASE SHEET FASTENING OPTION WITH | | MAXIMUM DESIGN PRESSURES OF -52.5PSF. PRODUCT APPROVAL | | SUBMITTED SHOWS APPROVED ASSEMBLY ON SHEET #17 WITH | | OPTION #1 BASE SHEET FASTENING OPTION WITH MAXIMUM | | DESIGN PRESSURES OF -45PSF. APPROVED ASSEMBLY SPECIFIED | | ON ENGINEER'S LETTER NEED TO MATCH APPROVED ASSEMBLY | | PROVIDED IN THE NOA SUBMITTED. COORDINATE AS REQUIRED. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2009-10-14 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2009-10-14 |
Time |
10:03 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2009-10-14 |
Time |
10:02 |
Sent To |
PC |
|
Notes |
2009-10-14 10:12:46 | RESIDENTIAL (R3) REROOF, BUILDING REVIEW CHECKLIST. | | 2007 FL. RESIDENTIAL CODE WITH 2009 REVISIONS. | | | | 1- CLEARLY MARK WHICH BASE SHEET FASTENING OPTION ON | | SHEET 17 OF NOA 07-1219.09 IS GOING TO BE INSTALLED TO | | VERIFY COMPLIANCE WITH THE DESIGN PRESSURES OF SEC. | | R301 OF 2007 FLORIDA RESIDENTIAL CODE. | | | | 2- PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS FOR | | NAIL ENHANCING AT PERIMETER AND CORNER AREAS AS | | REQUIRED ON LAST PAGE OF NOA SUBMITTED. | | NOTE: DESIGN PROFESSIONAL TO TAKE INTO CONSIDERATION | | THAT ACCORDING TO THE 2009 REVISIONS TO THE 2007 | | FLORIDA RESIDENTIAL CODE, THIS BUILDING IS LOCATED ON | | EXPOSURE "C". | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|
|
|