Plan Review Details - Permit 09100196
Plan Review Stops For Permit 09100196
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2009-11-18 Cont ID  
Sent By jwitmer Date 2009-11-18 Time 11:26 Rev Time 1.00
Received By jwitmer Date 2009-11-18 Time 11:26 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status N Date 2009-11-24 Cont ID  
Sent By jwitmer Date 2009-11-02 Time 11:30 Rev Time 0.00
Received By btrobaug Date 2009-11-02 Time 11:30 Sent To PC
Notes
2009-11-02 13:18:44BUILDING PLAN REVIEW
 PERMIT: 09100196
 ADD: 1028 GREEN PINE BLVD # 0070
 CONT: LIFETIME EXTERIORS
 TEL: (561)582-7101
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2008 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW
 ACTION: DENIED
  
 1) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER
 MARCH 1ST, 2009 SHALL BE REVIEWED TO THE 2007 FBC
 BUILDING WITH 2009 SUPPLEMENTS.
  
 PLANS WILL ALSO BE REVIEWED TO THE 2007 EXISTING
 BUILDING CODE W/ 2009 SUPPLEMENTS, PLEASE INDICATE TO
 WHAT LEVEL ALTERATION WILL BE COMPLETED UNDER THIS
 PERMIT.
 401.4 A DESIGN PROFESSIONAL OR AN OWNER MUST ELECT ONE
 OR A COMBINATION OF LEVELS OF ALTERATION PURSUANT TO
 SECTIONS 403, 404 AND 405 OF THIS CODE.
  
 2) PLEASE PROVIDE A SITE PLAN INDICATING WHICH BUILDING
 AND UNIT WHERE THE WORK IS TO TAKE PLACE (WHICH SIDE OF
 THE BUILDING), THIS MAY EFFECT THE EXPOSURE CATEGORY,
 FBC BUILDING 1609.4.
  
 3) PLANS FAIL TO INDICATE WIND DESIGN INFORMATION:
 1603.1.4 WIND DESIGN DATA.
 THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL
 BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE
 DESIGN OF THE LATERAL-FORCE-RESISTING SYSTEM OF THE
 BUILDING:
 3.1. BASIC WIND SPEED (3-SECOND GUST), MILES PER HOUR
 (KM/HR).
  
 3.2. WIND IMPORTANCE FACTOR, I W , AND BUILDING
 CLASSIFICATION FROM TABLE 1604.5 OR TABLE 6-1, ASCE 7
 AND BUILDING CLASSIFICATION IN TABLE 1-1, ASCE 7.
  
 3.3. WIND EXPOSURE, IF MORE THAN ONE WIND EXPOSURE IS
 UTILIZED, THE WIND EXPOSURE AND APPLICABLE WIND
 DIRECTION SHALL BE INDICATED.
  
 3.4. THE APPLICABLE ENCLOSURE CLASSIFICATIONS AND, IF
 DESIGNING WITH ASCE 7, INTERNAL PRESSURE COEFFICIENT.
  
 3.5. COMPONENTS AND CLADDING. THE DESIGN WIND PRESSURES
 IN TERMS OF PSF (KN/M 2 ) TO BE USED FOR THE SELECTION
 OF EXTERIOR COMPONENTS AND CLADDING MATERIALS NOT
 SPECIFICALLY DESIGNED BY THE REGISTERED DESIGN
 PROFESSIONAL.
  
 4) DISCREPANCY PLEASE REVIEW DOOR HEIGTH, THE PLAN
 INDICATES THE DOORS TO BE 84" WHERE AS THE PRODUCT
 APROVAL (08-0213.03 ) DOOR HEIGTH IS HIGHLIGHTED OR
 INDICATES AS A 6'-8", PLEASE UPDATE PLEASE CORRELATE
 INFORMATION.
  
 5) PLANS INDICATE THIS TO BE A SINGLE STORY BUILDING,
 AREN'T THE BUILDINGS IN THE NORTHWEST CORNER OF THE
 DEVELOPMENT 2 STORY STRUCTURES. 106.1.2 ADDITIONAL
 INFORMATION REQUIRED.
  
 6) PRODUCT APPROVAL FL 6231-R3 PLEASE HIGHLITE WHICH OF
 THE WALL PANEL TYPES ARE GOING TO BE INSTALLED ON THIS
 PROJECT, PLEASE INDICATE WHAT TYPE OF STRUCTRUAL
 MEMBERS THE SLIDING GLASS DOORS AS WELL AS THE
 ACCORDIAN SHUTTERS ARE GOING TO BE ATTACHED TOO.
  
 STARTING AUGUST 21, 2009, THE CONSTRUCTION SERVICES
 DEPARTMENT WILL BE CLOSED ON FRIDAYS UNTIL FURTHER
 NOTICE.
  
 OPENING HOURS MONDAY - THURSDAY WILL REMAIN AT 8:00 AM
 - 5:00 PM.
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
  
 PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE
 CUSTOMER SERVICE SURVEY AT:
 WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES
  
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  
  

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2009-11-24 Cont ID  
Sent By btrobaug Date 2009-11-03 Time 12:05 Rev Time 0.00
Received By btrobaug Date 2009-11-03 Time 11:49 Sent To I
Notes
2009-11-03 11:56:12 
  
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2007 FLORIDA RESIDENTIAL BUILDING CODE, 2009
 REVISIONS, 2005 NEC, 2004 FBC AS AMENDED, CHAPTER 1.AND
 FOUND NONCOMPLIANT WITH THE FOLLOWING:
  
 NO ELECTRICAL INFORMATION SUBMITTED. PROVIDE A PLAN
 INDICATING THE RATINGS AND LOCATION OF THE
 SHUTTER(S).SEPARATE PERMIT REQUIRED.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-11-03 Cont ID  
Sent By btrobaug Date 2009-11-24 Time 11:52 Rev Time 0.00
Received By btrobaug Date 2009-10-13 Time 09:47 Sent To  
Notes
2009-11-03 12:06:24TO SMALL HOLDING BINS UNDER "L"./WRT.
2009-10-13 09:47:27TO ZONING
  

Review Stop Z ZONING
Rev No 1 Status N Date 2009-10-21 Cont ID  
Sent By kdfreema Date 2009-10-21 Time 08:59 Rev Time 0.00
Received By btrobaug Date 2009-10-21 Time 08:59 Sent To B
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved