Plan Review Stops For Permit 09100193 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2009-11-30 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-11-30 |
Time |
16:58 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-11-30 |
Time |
16:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2009-11-17 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-11-17 |
Time |
13:25 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-11-17 |
Time |
13:25 |
Sent To |
|
|
Notes |
2009-11-17 13:26:10 | SEE PREVIOUS COMMENTS |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2009-11-02 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-11-02 |
Time |
07:58 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-11-02 |
Time |
07:58 |
Sent To |
|
|
Notes |
2009-11-02 08:06:45 | 2007 FBC W/2009 REVISIONS | | FREE FORM RESIDENTAL POOL W/PAVER DECK | | | | 1) UPDATE THE PLANS TO REFERENCE CODES THAT APPLY TO | | THIS PROJECT. THE 2007 FBC RESIDENTIAL AND THE 2008 | | NEC. | | | | 2) THE VALUE OF THE WORK SPECIFIED ON THE APPLICATION | | IS LOW. PLEASE REVISE THE VALUE TO INCLUDE THE COST OF | | THE RAISED BEAM WITH THE WATERFALL AND LION HEAD | | SPILLS, THE CONVERSATION PIT, THE ROCK ACCENTS, THE | | PAVER DECK AND STEPS TO THE RAISED AREA. FBC 108.3 | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2009-11-30 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-11-30 |
Time |
16:58 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-11-30 |
Time |
16:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2009-11-17 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-11-17 |
Time |
13:26 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-11-17 |
Time |
13:26 |
Sent To |
|
|
Notes |
2009-11-17 13:26:53 | SEE PREVIOUS COMMENTS |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2009-11-02 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-11-02 |
Time |
08:07 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-11-02 |
Time |
08:07 |
Sent To |
|
|
Notes |
2009-11-02 08:16:25 | 2007 FBCR AND 2008 NEC | | | | 1) REVISE THE PUMP SIZE ON THE ELECTRICAL DRAWING FROM | | 2 HP TO 1-1/2 HP TO CORRESPOND WITH THE PUMP SIZE | | SPECIFIED ON SHEET 1. | | | | 2) UPDATE THE ELECTRICAL CODE REFERENCES TO THE 2008 | | NEC WHICH CAME INTO EFFECT ON OCTOBER 1, 2009. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2009-11-02 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-11-02 |
Time |
08:06 |
Rev Time |
|
Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2009-11-02 08:07:31 | NO GAS INDICATED ON PLANS. |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2009-10-08 |
|
|
Cont ID |
|
Sent By |
swurafti |
Date |
2009-10-08 |
Time |
17:13 |
Rev Time |
0.00 |
Received By |
swurafti |
Date |
2009-10-08 |
Time |
14:42 |
Sent To |
|
|
Notes |
2009-10-08 17:13:34 | HISTORIC APPROVED BY JPAPA |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2009-11-02 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-11-02 |
Time |
08:47 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-10-13 |
Time |
11:28 |
Sent To |
|
|
Notes |
2009-10-13 11:28:24 | TO ZONING | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2009-12-01 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-12-01 |
Time |
07:04 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-12-01 |
Time |
07:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2009-11-16 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-11-16 |
Time |
10:10 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-11-16 |
Time |
10:10 |
Sent To |
|
|
Notes |
2009-11-16 10:19:47 | 2007 FBC W/2009 REVISIONS | | RESIDENTIAL POOL | | | | DENIED BY PLUMBING | | | | 1) THE WATER VELOCITY IN THE 1-1/2 " RETURN LINES | | SPECIFIED ON THE PLANS WILL EXCEED THE 10 FT PER SECOND | | ALLOWED BY FBC R4101.6.3 FOR THE 1-1/2 HP PUMP THAT IS | | SPECIFIED. THE SIMPLIFIED TDH IS SHOWN AS 43.9 ON THE | | WORKSHEET AND THE PUMP SPECIFIED HAS A 90 GPM OUTPUT AT | | 40 FT OF HEAD. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2009-11-02 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-11-02 |
Time |
08:16 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-11-02 |
Time |
08:16 |
Sent To |
|
|
Notes |
2009-11-02 08:47:17 | 2007/FBCR W/2009 REVISIONS | | | | DENIED BY PLUMBING | | | | 1) ON SHEET 2, REVISE THE PUMP SIZE TO 1-1/2 HP TO | | CORRESPOND WITH THE SIZE SPECIFIED ON SHEET 1. | | | | 2) SUBMIT 2 COPIES OF TOTAL DYNAMIC HEAD CALCULATIONS | | (TDH) AND PUMP CURVE GRAPHS FOR THE 1-1/2 HP PUMP THAT | | WILL BE INSTALLED. CALCULATIONS MUST SHOW THAT THE FLOW | | RATE DOES NOT EXCEED 6 FT/SEC IN THE MAIN DRAIN BRANCH | | PIPING. FBC R4101.6.3 | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2009-10-15 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2009-10-15 |
Time |
11:41 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2009-10-15 |
Time |
11:41 |
Sent To |
E |
|
Notes |
2009-10-15 11:42:13 | ZONING PLAN REVIEW | | | | PERMIT NO.: 09100193 | | ADDRESS: 3007 WASHINGTON ROAD | | CONTRACTOR/CONTACT: CUSHING SWIMMING POOL CONST. INC. | | TELEPHONE NO.: 561.798.1441 | | SCOPE OF REVIEW: POOL WITH PAVER DECK, CONVERSATION | | PIT, AND SHEER DESCENT WATERFALL | | | | REVIEW STATUS: PASSED WITH PROVISOS | | | | THIS REVIEW HAS BEEN PASSED SUBJECT TO THE FOLLOWING | | PROVISOS: | | | | 1) PERMIT INDICATES EXISTING 6 FOOT FENCE/WALL. ENSURE | | FENCE/WALL COMPLETELY ENCLOSES THE POOL TO OBSTRUCT | | ACCESS BY PERSONS OTHER THAN THE OWNERS/OCCUPANTS. | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | JOHN ROACH, SENIOR PLANNER | | CITY OF WEST PALM BEACH | | PLANNING AND ZONING DEPARTMENT | | 401 CLEMATIS STREET - P.O. BOX 3366 | | WEST PALM BEACH, FLORIDA 33402 | | | | PHONE: 561.822.1435 | | FAX: 561.822.1460 | | | | EMAIL: [email protected] | | | | WWW.CITYOFWPB.COM |
|
|