Plan Review Stops For Permit 09090516 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2009-11-16 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2009-11-16 |
Time |
16:11 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2009-11-16 |
Time |
16:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2009-10-01 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2009-10-01 |
Time |
14:57 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2009-10-01 |
Time |
14:57 |
Sent To |
|
|
Notes |
2009-10-01 17:01:02 | RESIDENTIAL (R3) ADDITION/ALTERATION BUILDING REVIEW | | CHECKLIST. | | 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS. | | | | 1- BRING PLANS TO PALM BEACH COUNTY TO VERIFY IF IMPACT | | FEES ARE DUE. PLEASE, BRING BACK STAMPED PLANS AND COPY | | OF PAID RECEIPT IF FEES ARE DUE. | | | | 2- PROVIDE ENERGY CALCULATIONS. PLEASE, MAKE SURE | | CORRECT UPDATED AND COMPLETE FORM IS PROVIDED AND ALL | | SIGNATURES AND DATES ARE INCLUDED. | | | | 3- PROVIDE COMPLETE FRAMING DETAILS FOR ALL NEW DOORS | | AND WINDOWS INSTALLATION, INCLUDING GARAGE DOOR TO | | VERIFY COMPLIANCE WITH THE DESIGN PRESSURES OF SECTION | | R301 OF 2007 FLORIDA RESIDENTIAL CODE. SPECIFY ALL | | FRAMING MEMBERS AND ANCHORS. | | | | 4- PROVIDE DETAILS/SPECIFICATIONS SHOWING HOW IS THE | | EXISTING ROOF GOING TO BE REINFORCED IF THE TRUSSES | | BOTTOM CHORD IS GOING TO BE REMOVED IN THE CABANA AREA. | | TRUSSES BEARING POINTS ARE CHANGED WHEN REMOVING THE | | TRUSS WEBS AND BOTTOM CHORD. SEC. 106.1.2 OF CITY | | AMENDMENTS TO FBC TO VERIFY COMPLIANCE WITH THE DESIGN | | LOADS OF SEC. R301 OF 2007 FLORIDA RESIDENTIAL CODE. | | | | 5- SECTION "C" ON SHEET A1: SPECIFY ROOF VENTILATION | | SIZE AND LOCATION TO VERIFY COMPLIANCE WITH SEC. R806. | | | | 6- PROVIDE NOTICE OF COMMENCEMENT. SEC. 713.13 FLORIDA | | STATUTE. | | ***NOTE: THIS MAY BE PROVIDED AT TIME OF PERMIT PICK | | UP. | | | | 7- ALL PRODUCT APPROVALS NEED TO BE REVIEWED AND | | APPROVED IN WRITING (NOT SIGNING AND SEALING) BY THE | | ENGINEER OF RECORD AS REQUIRED BY SEC. 106.3.3 CITY | | AMENDMENTS TO FBC. | | | | JULIO GOMEZ | | COMBINED COMMERCIAL PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2009-11-17 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-11-17 |
Time |
16:38 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-11-17 |
Time |
16:38 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2009-10-08 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-10-08 |
Time |
19:42 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-10-08 |
Time |
19:42 |
Sent To |
|
|
Notes |
2009-10-08 19:42:52 | ** DENIED PLANS ** | | | | ** SOME OF THE ITEMS BELOW WOULD TYPICALLY BE REDLINED | | HOWEVER THERE ARE SEVERAL OF THESE ITEMS WHICH COULD | | NOT. | | | | 1) NOTE: PLANS INDICATE A RECEPTACLE FOR WATER HEATER | | CONNECTION. PLEASE SEE 422.30, 422.31 FOR REQUIRED | | DISCONNECT AND UNIT TO BE HARD-WIRED. | | | | 2) NOTE: PLEASE SUBMIT THE FOLLOWING INFORMATION: | | A) NO LOAD INFORMATION SHOWN FOR ELECTRICAL PANEL | | SCHEDULE. NEC 220. PLEASE ALSO INCLUDE NEW LOADS AND | | EXISTING SERVICE LOADS. | | B) NO INFORMATION ON WHAT SIZE PANEL IS FEEDING LOADS. | | C) NO INFORMATION FOR FEEDERS. 240.4, 310.15B6, 310.16, | | 215.5 ETC | | D) NO INFORMATION FOR MEANS OF DISCONNECT AT DETACHED | | STRUCTURE PER 225.31-225.39 OR 230.70,71. | | E) NO INFORMATION ON GROUNDING ELECTRODE SYSTEM AT THE | | DETACHED BUILDING PER 250.32, 250.50 | | | | 3) NOTE: MISSING WALL RECEPTACLE PER 210.52 | | | | 4) NOTE: MISSING GARAGE RECEPTACLE PER 210.52G ALSO IS | | REQUIRED TO BE GFI PER 210.8A2 | | | | 5) NOTE: *REDLINED SMOKE DETECTOR TO SMOKE ALARM. | | NFPA-72 11.5.1, PLEASE ALSO SEE FLORIDA STATUES 553.885 | | FOR REQUIRED CARBON MONOXIDE DETECTOR/ALARM. | | | | 6) NOTE: ARC FAULT PROTECTION PER 210.12 | | | | 7) NOTE: GFI IN BATHROOM PER 210.8A1. PLAN INDICATES | | THE RECEPTACLE BUT NOT THE GFI. | | | | 8) NOTE: PANEL SCHEDULE INDICATES WALL MOUNTED A/C UNIT | | HOWEVER PLANS DO NOT SHOW THE ELECTRICAL RECEPTACLE | | LOCATION FOR UNIT. PLANS ONLY INDICATE THE GENERAL | | PURPOSE RECEPTACLES. | | | | **IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | CONTACT THIS REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2009-11-10 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2009-11-10 |
Time |
07:40 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2009-11-10 |
Time |
07:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2009-10-08 |
Time |
|
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2009-09-24 |
Time |
08:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2009-11-16 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2009-11-16 |
Time |
11:52 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2009-11-16 |
Time |
11:52 |
Sent To |
|
|
Notes |
2009-11-16 11:53:51 | NO FEES DUE. SEE STAMPED PLANS. |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2009-10-05 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2009-10-05 |
Time |
11:07 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2009-10-05 |
Time |
11:07 |
Sent To |
|
|
Notes |
2009-10-05 11:08:04 | NEED PALM BEACH COUNTY STAMPED PLANS AND COPY OF PAID | | RECEIPT IF FEES ARE DUE. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2009-11-16 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2009-11-16 |
Time |
16:01 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2009-11-16 |
Time |
16:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2009-10-01 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2009-10-01 |
Time |
14:41 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2009-10-01 |
Time |
14:41 |
Sent To |
|
|
Notes |
2009-10-01 14:56:04 | RESIDENTIAL (R3) ADDITION/ALTERATION, MECHANICAL | | REVIEW. | | 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS. | | | | 1- SPECIFY CAPACITY OF EXHAUST FAN ON NEW CABANA TOILET | | AS REQUIRED BY SEC. M1507 AND TABLE M1507.3 OF 2007 | | FLORIDA RESIDENTIAL CODE. | | | | JULIO GOMEZ | | PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2009-10-05 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2009-09-28 |
Time |
10:12 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2009-09-28 |
Time |
10:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2009-11-16 |
|
|
Cont ID |
|
Sent By |
kdfreema |
Date |
2009-11-16 |
Time |
14:14 |
Rev Time |
0.00 |
Received By |
kdfreema |
Date |
2009-11-16 |
Time |
14:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2009-09-29 |
|
|
Cont ID |
|
Sent By |
kdfreema |
Date |
2009-09-29 |
Time |
15:55 |
Rev Time |
0.00 |
Received By |
kdfreema |
Date |
2009-09-29 |
Time |
15:55 |
Sent To |
|
|
Notes |
|
|