Plan Review Details - Permit 09090370
Plan Review Stops For Permit 09090370
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2009-11-18 Cont ID  
Sent By shill Date 2009-11-18 Time 15:39 Rev Time 0.00
Received By shill Date 2009-11-18 Time 15:39 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2009-10-13 Cont ID  
Sent By shill Date 2009-10-13 Time 11:56 Rev Time 0.00
Received By shill Date 2009-10-20 Time 11:56 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2009-11-18 Cont ID  
Sent By dpalmer Date 2009-11-18 Time 13:11 Rev Time 0.00
Received By dpalmer Date 2009-11-18 Time 13:11 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2009-10-07 Cont ID  
Sent By dpalmer Date 2009-10-07 Time 15:14 Rev Time 0.00
Received By dpalmer Date 2009-10-07 Time 15:14 Sent To B
Notes
2009-10-07 15:15:24 
  
 ** DENIED **
  
 1) NOTE: BASED ON COMMENTS FOR OTHER TRADES SUCH AS
 ZONING IT APPEARS THERE WILL BE CHANGES IN THE DESIGN
 OF THE SIGN.
  
 2) NOTE: PLEASE SUBMIT MORE INFORMATION ON THE
 ELECTRICAL BEING INSTALLED. PLANS GIVE VERY BASIC
 INFORMATION.
 PLEASE SEE NEC 600 FOR ALL WIRING REQUIREMENTS FOR
 SIGNS.
  
 SHOW ALL DISCONNECTS FOR EACH POWER FEED/BRANCH CIRCUIT
 PLANS STATE THERE WILL BE LED BULBS HOWEVER NOT
 INFORMATION ON DRIVERS.
 PLEASE PROVIDE MORE ELECTRICAL DETAILS.
  
 ** NEC 600 GIVEN IN GENERAL AS PLANS ARE NOT SPECIFIC
 ENOUGH FOR DETAILS AND REVIEW.
  
 3) NOTE: PERMIT APPLICATION WAS MADE WITHOUT THE SUITE
 OR UNIT NUMBER. 550 S. ROSEMARY AVE IS A BLOCK OF
 SEVERAL TENANTS. PLEASE OBTAIN CORRECT SUITE NUMBER.
  
  
  
  
  
 ** AS THERE IS INFORMATION NOT YET SUBMITTED REQUIRED
 FOR MINIMUM CODE COMPLIANCE REVIEW THERE MAY VERY WELL
 BE NEW COMMENTS ON THE FOLLOWING REVIEW WHICH CAN NOT
 BE MADE AT THIS TIME.
  
  
 **IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT
 TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO
 CONTACT THIS REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2009-11-09 Cont ID  
Sent By jgomez Date 2009-11-09 Time 11:47 Rev Time 0.00
Received By jgomez Date 2009-11-09 Time 11:47 Sent To Z
Notes
2009-11-09 11:48:17SENT TO ZONING BOX.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-10-20 Cont ID  
Sent By shill Date 2009-10-13 Time 11:58 Rev Time 0.00
Received By shill Date 2009-09-16 Time 10:03 Sent To  
Notes
2009-09-22 10:04:20GAVE TO ZONING ON 9/22

Review Stop Z ZONING
Rev No 2 Status P Date 2009-11-17 Cont ID  
Sent By eschneid Date 2009-11-17 Time 16:54 Rev Time 1.00
Received By eschneid Date 2009-11-17 Time 16:54 Sent To E
Notes
2009-11-17 16:55:07PASSED
  
 NO EXPOSED NEON IS ALLOWED.

Review Stop Z ZONING
Rev No 1 Status F Date 2009-09-29 Cont ID  
Sent By eschneid Date 2009-09-29 Time 18:22 Rev Time 0.50
Received By eschneid Date 2009-09-29 Time 18:22 Sent To E
Notes
2009-09-29 18:22:43FAILED
  
 1) THE CITYPLACE MASTER SIGN PLAN DOES NOT ALLOW
 EXPOSED NEON SIGNS - THIS INCLUDES NEON WITH A CLEAR
 COVER. NEON IS ONLY PERMITTED HIDDEN FROM VIEW IN BACK
 LIT SIGNS.
  
 2) THE CITYPLACE MATER SIGN PLAN REQUIRES THAT TEXT
 HEIGHT ON SIGNS BE SIZED BETWEEN 8 AND 12 INCHES IN
 HEIGHT. PROVIDE THE HEIGHT OF THE SIGN TEXT ON THE
 PLANS. NOTE: THE CITYPLACE MASTER SIGN PLAN ALLOWS A
 VARIANCE FROM THIS PROVISION PROVIDED THAT IT IS IN
 WRITING BY CITYPLACE.
  
 THESE COMMENTS HAVE BEEN SENT TO CARLOS BERNAL AT
 CITYPLACE.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.
  