Plan Review Details - Permit 09090324
Plan Review Stops For Permit 09090324
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2010-01-06 Cont ID  
Sent By jgomez Date 2010-01-06 Time 16:17 Rev Time 0.00
Received By jgomez Date 2010-01-06 Time 16:17 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2009-11-02 Cont ID  
Sent By jgomez Date 2009-11-02 Time 16:40 Rev Time 0.00
Received By jgomez Date 2009-11-02 Time 16:39 Sent To  
Notes
2009-11-03 11:54:29RESIDENTIAL (R3) ADDITION/ALTERATION, BUILDING REVIEW
 CHECKLIST.
 2007 FL. RESIDENTIAL CODE WITH 2009 REVISIONS.
  
 1- PROVIDE UPDATED FORM FOR THE ENERGY CALCULATIONS.
 SEE 2009 REVISIONS TO THE 2007 FLORIDA RESIDENTIAL CODE
 AND COMPLETE CORRECT UPDATED FORM. FORMS 1100C ARE NO
 LONGER USED.
 ***NOTES:
 A) PLEASE MAKE SURE FORM IS FILLED UP COMPLETELY AND
 WITH INFORMATION THAT MATCHES PLANS SUBMITTED.
 B) OWNER/AGENT TO SIGN AND DATE BOTTOM OF FORM.
  
 2- BRING PLANS TO THE PALM BEACH COUNTY TO VERIFY IF
 IMPACT FEES ARE DUE. BRING BACK STAMPED PLANS AND COPY
 OF PAID RECEIPT IF FEES ARE DUE.
  
 3- SHEET SITE-1:
 A) REVISE DESIGN ASSUMPTION NOTES. ACCORDING TO SEC.
 R301.2.1.4.3 OF THE 2009 REVISIONS TO THE 2007 FLORIDA
 RESIDENTIAL CODE THIS PROPERTY IS LOCATED ON EXPOSURE
 "C" NOT "B".
  
 B) DESIGN ASSUMPTION NOTES ARE NOT LEGIBLE. THERE IS
 OVERLAPPING INFORMATION. REVISE AS REQUIRED.
  
 C) SETBACK DIMENSIONS SHOWN ON THE PROPOSED SITE PLAN
 DON'T MATCH SURVEY. REVISE AS REQUIRED.
  
 D) SPECIFY THE ATTIC LIVE LOADS AS REQUIRED BY TABLE
 R301.5 OF 2007 FLORIDA RESIDENTIAL CODE.
  
 4- SHEET S-2:
 A) REVISE ROOF DIAPHRAGM NAILING DETAIL AND
 SPECIFICATIONS. SEE FIGURE R301.2(7) FOR CORRECT ROOF
 ZONE 3 IDENTIFICATION (NEED TO INCLUDE THE HIP ROOF
 CORNERS) AND SEC. R803.2.3.1 OF 2007 FLORIDA
 RESIDENTIAL CODE FOR CORRECT ROOF ZONE 3 NAILING
 SPACING (ZONE 3 REQUIRES 4" O.C. AT EDGES AND
 INTERMEDIATE).
  
 5- OWES $2.10 FOR RADON FEES.
  
 6- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9B-72 FOR HARDIBOARD TO BE INSTALLED. SEE
 PLANS SUBMITTED.
  
 7- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC.
  
 8- ROOF PITCH OF 3:12 REQUIRES TWO LAYERS OF
 UNDERLAYMENT. SEC. R905.2.2 OF 2007 FLORIDA RESIDENTIAL
 CODE. SPECIFY ON PLANS THAT 2 LAYERS OF UNDERLAYMENT
 ARE REQUIRED.
  
 9- REVISE THICKNESS OF STUCCO SPECIFIED ON PLANS. TABLE
 R702.1(1) OF 2007 FLORIDA RESIDENTIAL CODE REQUIRES
 7/8" THICKNESS NOT 3/4".
  
 10- SPECIFY ATTIC SIZE AND LOCATION AS REQUIRED BY SEC.
 R807 OF 2007 FLORIDA RESIDENTIAL CODE.
  
 11- SURVEY TO HAVE ORIGINAL SIGNATURE (NOT COPY) AS
 REQUIRED BY CHAPTER 472 FLORIDA STATUTE.
  
 12- SOIL TEST REPORT TO HAVE ENGINEER'S ORIGINAL
 SIGNATURE (NOT COPY) AS REQUIRED BY CHAPTER 471 FLORIDA
 STATUTE.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2010-01-14 Cont ID  
Sent By btrobaug Date 2010-01-14 Time 11:08 Rev Time 0.00
Received By btrobaug Date 2010-01-14 Time 11:08 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2009-11-18 Cont ID  
Sent By btrobaug Date 2009-11-18 Time 13:02 Rev Time 0.00
Received By btrobaug Date 2009-11-18 Time 11:37 Sent To  
Notes
2009-11-18 12:57:16PROVISO
 REVISION REQUIRED TO CORRECT THE FOLLOWING.
  
 1) REMOVE EQUIPMENT GROUND FROM METER TO DISCONNECT.
 250.24(A) (5).
  
 2} GROUNDING ELECTRODE MUST BE A #4. 250.66
  
 3} HVAC CALCULATION INCORRECT IN THE LOAD CALCULATION.
 220.82 AND OR 220.83.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2010-01-04 Cont ID  
Sent By shill Date 2010-01-04 Time 14:24 Rev Time 0.00
Received By shill Date 2010-01-04 Time 14:24 Sent To  
Notes
2010-01-04 14:24:52R5
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2009-09-16 Time   Rev Time 0.00
Received By lmartine Date 2009-09-16 Time 09:58 Sent To  
Notes
2009-09-22 10:01:14R-7

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2010-01-06 Cont ID  
Sent By jgomez Date 2010-01-06 Time 14:51 Rev Time 0.00
Received By jgomez Date 2010-01-06 Time 14:51 Sent To  
Notes
2010-01-06 14:53:34TRACKING NO. MU-2009-022261-0000.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2009-11-02 Cont ID  
Sent By jgomez Date 2009-11-02 Time 16:52 Rev Time 0.00
Received By jgomez Date 2009-11-02 Time 16:52 Sent To  
Notes
2009-11-02 16:54:091- NEED TO BRING PLANS TO PALM BEACH COUNTY TO VERIFY
 IF IMPACT FEES ARE DUE. BRING BACK STAMPED PLANS AND
 COPY OF PAID RECEIPT IF FEES ARE DUE.

Review Stop L LANDSCAPING
Rev No 2 Status N Date 2010-01-12 Cont ID  
Sent By rkussner Date 2010-01-12 Time 11:31 Rev Time 0.00
Received By rkussner Date 2010-01-12 Time 11:31 Sent To  
Notes
***NONE***

Review Stop L LANDSCAPING
Rev No 1 Status F Date 2009-09-29 Cont ID  
Sent By rkussner Date 2009-09-29 Time 16:30 Rev Time 0.00
Received By rkussner Date 2009-09-29 Time 16:30 Sent To  
Notes
2009-09-29 16:49:39***LANDSCAPE REVIEW FAILED***
  
 PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN WRITTEN
 FORMAT.
  
 1, SUBMIT COST ESTIMATE THAT INCLUDES THE TOTAL COST OF
 ALL LANDSCAPING AND INSTALLATION, BROKEN DOWN INTO UNIT
 COST.
  
 2. SUBMIT A LANDSCAPE PLAN AND THE TABULATION NECESSARY
 FOR THE EVALUATION OF COMPLIANCE WITH ARTICLE XIV OF
 THE ZONING AND LAND DEVELOPMENT REGULATIONS, INCLUDING
 THE XERISCAPE DESIGN OPTIONS. .
  
 3. PURSUANT TO SECTION 94-448 (D)(2), THE LANDSCAPE
 PLAN SHALL INCLUDE ALL OF THE ITEMS MENTIONED IN THIS
 SECTION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT
 KUSSNER @ (561) 822-1462.

Review Stop P PLUMBING
Rev No 2 Status P Date 2010-01-06 Cont ID  
Sent By kstevens Date 2010-01-06 Time 08:47 Rev Time 0.00
Received By kstevens Date 2010-01-06 Time 08:47 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2009-10-21 Cont ID  
Sent By kstevens Date 2009-10-21 Time 17:09 Rev Time 0.00
Received By kstevens Date 2009-10-21 Time 17:09 Sent To  
Notes
2009-10-21 17:16:23DENIED
 REFERENCE:
 FBC-2007 RESIDENTIAL
 FBC-2007 CHAPTER 1 (ADMIN)
  
 1. SHT SITE-1 INDICATES THE WASH MACHINE WILL BE
 RELOCATED TO NEW LAUNDRY ROOM. PER SECTION
 106.3.5.1.4(9) A SANITARY RISER DIAGRAM IS REQUIRED.
 PLEASE SUBMIT A SANITARY RISER DIAGRAM SHOWING ALL PIPE
 SIZES, TRAPS, STANDPIPES & VENTS PER SECTIONS 3005,
 3101, 3201. 3" PIPE IS REQUIRED FOR THE BRANCH LINE &
 STACK FOR THE AUTOMATIC WASH MACHINE. SECTION 406.3.
  
 2. MORE INFORMATION IS REQUIRED. PLEASE SHOW THE
 LOCATION OF THE WASH MACHINE ON THE EXISTING FLOOR
 PLAN. SECTION 106.1.2.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]
  

Review Stop Z ZONING
Rev No 2 Status P Date 2010-01-12 Cont ID  
Sent By eschneid Date 2010-01-12 Time 11:24 Rev Time 0.50
Received By eschneid Date 2010-01-12 Time 11:24 Sent To  
Notes
2010-01-12 11:26:05NOTE: SURVEY SHOWS INCORRECT DIMENSION OF THE WEST SIDE
 OF THE ADDITION, THEREFORE ZONING ONLY STAMPING THE
 ARCHITECTURAL PLANS.
  
 VALUE NOT CERTIFIED UNTIL OCTOBER 2009, THEREFORE THIS
 PERMIT DOES NOT TRIP 50% RULE.

Review Stop Z ZONING
Rev No 1 Status F Date 2009-09-28 Cont ID  
Sent By eschneid Date 2009-09-28 Time 17:50 Rev Time 0.00
Received By eschneid Date 2009-09-28 Time 17:50 Sent To  
Notes
2009-09-28 17:58:04FAILED
  
 1) PURSUANT TO SECTION 94-441(C)(2) OF THE ZONING AND
 LAND DEVELOPMENT REGULATIONS (ZLDR): AS THE VALUE OF
 THE PROPOSED WORK EXCEEDS 50% OF THE STRUCTURE'S VALUE
 (LISTED AS "IMPROVEMENT VALUE" WITH THE P.B.C. PROPERTY
 APPRAISER'S OFFICE), LANDSCAPING SHALL BE IN COMPLIANCE
 WITH ALL APPLICABLE REGULATIONS FOUND IN ARTICLE XIV OF
 THE ZLDR. PERMIT VALUE IS $30,000 AND IMPROVEMENT VALUE
 IS $57,590.
  
 2) PLEASE SUBMIT TWO (2) COPIES OF A LANDSCAPE PLAN
 SHOWING COMPLIANCE WITH SECTIONS 94-442 AND 94-445 OF
 THE ZLDR.
  
 3) THE SETBACK DIMENSIONS LISTED ON THE SURVEY AND THE
 SITE PLAN DO NOT MATCH. PLEASE REVISE ACCORDINGLY.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.