Plan Review Details - Permit 09090315
Plan Review Stops For Permit 09090315
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2010-04-28 Cont ID  
Sent By lmartine Date 2010-04-28 Time 16:09 Rev Time 0.00
Received By lmartine Date 2010-04-28 Time 16:09 Sent To  
Notes
2010-04-28 16:10:45THIS PERMIT INCLUDES EXTERIOR AND INTERIOR RENOVATIONS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2009-10-31 Cont ID  
Sent By lmartine Date 2009-10-31 Time 12:07 Rev Time 0.00
Received By lmartine Date 2009-10-31 Time 12:07 Sent To  
Notes
2009-10-31 12:25:36BUILDING REVIEW COMMENTS
  
  
 1)
 PROVIDE DRAWINGS FOR SCOPE OF WORK ONLY OR CHANGE
 PERMIT APPLICATION DESCRIPTION TO INCLUDE ALL WORK
 SHOWN ON DRAWINGS.
  
 2)
 THE 2007 FLORIDA ACCESSIBILITY CODE REQUIRES THE
 FOLLOWING,
 11-4.5.2 ACCESSIBLE ENTRANCE AT THE DOORWAY SHALL NOT
 EXCEED 1/2" ELEVATION CHANGE.
 11-4.8.3 RAMPS THAT ARE PART OF A MEANS OF EGRESS TO BE
 MIN. 44" WIDE.
 11-4.8.4 PROVIDE 60" CLEAR LANDING AT THE TOP AND 72"
 STRAIGHT RUN AT THE BOTTOM OF THE RAMP.
  
 3)
 A CHANGE OF USE APPLICATION WILL BE REQUIRED FOR A DAY
 CARE OCCUPANCY.
  
 4)
 A RIGHT OF WAY PERMIT WILL BE REQUIRED FOR ANY
 ALTERATIONS TO THE CITY CURB AND SIDEWALK.
  
  
 LUIS MARTINEZ
 561-805-6710

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2010-04-29 Cont ID  
Sent By btrobaug Date 2010-04-29 Time 16:17 Rev Time 0.00
Received By btrobaug Date 2010-04-29 Time 16:17 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2010-04-29 Cont ID  
Sent By mawillia Date 2010-04-29 Time 12:42 Rev Time 0.00
Received By mawillia Date 2010-04-29 Time 11:11 Sent To  
Notes
2010-04-29 12:42:45*****APPROVED W/REMINDERS*****
  
 THE COMMENTS FROM THE PREVIOUS REVIEW HAVE BEEN
 ADDRESSED; PLAN SHEETS 5.0, 5.2, 5.3, 5.4, 6.1, AND 7.0
 WERE STAMPED, INITIALED, AND DATED. THE FOLLOWING
 REMINDERS WERE ATTACHED AS FOLLOWS:
  
  
  
 SHEET 7.0
 * ADDRESS NUMBERS SHALL BE NO LESS THAN 6" IN HEIGHT
 AND NO LESS THAN 1" IN WIDTH/STROKE (AS PER WEST PALM
 BEACH CODE)
  
  
 SHEET 5.3
 * INTERIOR WALL AND CEILING FINISH MATERIAL SHALL BE
 CLASS A IN STAIRWAYS, CORRIDORS, AND LOBBIES; IN ALL
 OTHER OCCUPIED ARES, INTERIOR WALL AND CEILING FINISH
 MATERIALS SHALL BE CLASS A OR CLASS B
 * INTERIOR FLOOR FINISH SHALL COMPLY WITH 10.2.7.1 OR
 10.2.7.2, AS APPLICABLE, IN ACCORDANCE WITH NFPA 101,
 LIFE SAFETY CODE, 2006 EDITION.
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2009-10-07 Cont ID  
Sent By mcarsill Date 2009-10-07 Time 07:21 Rev Time 0.00
Received By mcarsill Date 2009-10-07 Time 07:14 Sent To  
Notes
2009-10-07 07:21:19 
 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY
 WITH NFPA 241.
  
 2. SUITABLE EXITS ARE TO BE PROVIDED DURING
 CONSTRUCTION.
  
 3. BUILDING ADDRESS REQUIRED. A MINIMUM OF AT LEAST 6 "
 HIGH AND AT LEAST 1" WIDE SHALL BE PROVIDED. THESE
 NUMBERS SHOULD CONTRAST WITH THE BACKGROUND THEY ARE
 AFFIXED TO.
  
 4. PLEASE INDICATE PRESCRIPTIVE STRENGTH REQUIREMENTS
 FOR ALL HANDRAILS AND GUARDRAILS.
  
 5. PLANS INDICATE A CHANGE OF USE FROM A B TO A D
 OCCUPANCY.
  
 6. PLANS DO NOT ILLUSTRATE ANY SAFETY SYSTEMS OR
 DEVICES. THESE INCLUDE ILLUMINATED EXIT SIGNS,
 EMERGENCY LIGHTS, SMOKE ALARMS, AND PORTABLE FIRE
 EXTINGUISHERS.
  
 7. BATHROOM DOORS SHALL BE OPERABLE FROM OUTSIDE THESE
 ROOMS.
  
 8. CLOSET DOOR LOCKS SHALL BE OPERABLE FROM INSIDE.
  
 9. PLEASE INDICATE INTERIOR FINISH CLASSIFICATIONS FOR
 WALLS AND CEILINGS.
  
 10. A FIRE ALARM SYSTEM IS REQUIRED. SEPARATE PLANS AND
 PERMITS REQUIRED PRIOR TO INSTALLATION.
  
 11. PLEASE INDICATE INTERIOR FLOOR FINISH.
  
 12. PLEASE INDICATE THE TYPES OF DOOR HARDWARE AND ANY
 LOCKING DEVICES.
  
 13. PLEASE INDICATE TREAD DEPTH FOR STAIR TREADS.
  
 14. AN EMERGENCY PLAN SHALL BE STARTED AS IT WILL NEED
 TO BE COMPLETED PRIOR TO OPENING.
  
 DENIED.
  
  
 MIKE CARSILLO, BATTALION CHIEF
 BUREAU OF FIRE PREVENTION

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-10-31 Cont ID  
Sent By lmartine Date 2009-10-31 Time 12:25 Rev Time 0.00
Received By lmartine Date 2009-09-16 Time 09:45 Sent To  
Notes
2009-09-22 09:46:14B-3

Review Stop L LANDSCAPING
Rev No 2 Status N Date 2010-04-30 Cont ID  
Sent By lmartine Date 2010-04-30 Time 08:52 Rev Time 0.00
Received By lmartine Date 2010-04-30 Time 08:52 Sent To  
Notes
2010-04-30 08:53:33SEE LANDSCAPE PERMIT #10030722 PER R.KUSSNER

Review Stop L LANDSCAPING
Rev No 1 Status F Date 2009-09-29 Cont ID  
Sent By rkussner Date 2009-09-29 Time 13:28 Rev Time 0.00
Received By rkussner Date 2009-09-29 Time 11:21 Sent To  
Notes
2009-09-29 15:39:31***LANDSCAPE REVIEW FAILED****
  
 PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN WRITTEN
 FORMAT.
  
 1. PROVIDE A CERTIFIED COST ESTIMATE THANT INCLUDES THE
 TOTAL COST OF ALL LANDSCAPE MATERIALS AND LABOR. IT
 SHALL BE BROKEN DOWN INTO UNIT COST.
  
 2, PURSUANT TO SECTION 94-443 (A)(2)(B), ALL PORTIONS
 OF THE LANDSCAPE STRIP THAT BUFFERS THE NONRESIDENTIAL
 USE ADJACENT TO RESIDENTIAL PROPERTY SHALL BE
 LANDSCAPED. MULCH, WITHOUT PLANT MATERIAL, IS NOT
 CONSIDERED LANDSCAPING. THE BUFFER IS REQUIRED TO BE A
 MINIIMUM OF FIVE FEET IN WIDTH.THIS APPLIES TO THE
 SOUTH SIDE OF THE SITE. A HEDGE OR OTHER PLANTING AND
 SOD OR GROUND COVER IS RECOMMENDED FOR THE AREA.THE
 FENCE SHOULD BE MOVED TO THE PROPERTY LINE. AN EASEMENT
 AGREEMENT WILL BE REQUIRED TO INSTALL THE FENCE AND
 LANDSCAPING WITHIN THE UTILITIY EASEMENT. IF THE FENCE
 REMAINS IN THE CURRENT LOCATION, A GATE WILL NEED BE
 ADDED FOR ACCESS TO MAINTAIN THE AREA BETWEEN THE FENCE
 AND PROPERTY LINE.
  
 3. PURSUANT TO SECTION 94-443 (B)(3), TREES, GHRUBS,
 GRASS, GROUND COVER, OR OTHER SUITABLE LIVE PLANT
 MATERIAL SHALL BE PLANTED OVER THE ENTIRE LANDSCAPE
 STRIP, REQUIRED TO BUFFER NONRESIDENTIAL USES ADJACENT
 TO A PUBLIC THROROUGHFARE AND NONRESIDENTIAL ZONING
 DISTRICT. MULCH, ALONE, IS NOT ACCEPTABLE. A HEDGE AND
 GROUND COVER OR SOD AND AT LEASE ONE SHADE TREE FOR
 EACH 30 LINEAR FEET IS REQUIRED ALONG THE EAST, NORTH
 AND WEST SIDES OF THE SITE.
  
 4. PURSUANT TO SECTION 94-442 (C), PALM TREES MAY BE
 SUBSTITUTED FOR NOT MORE THAN 35 PERCENT OF THE SHADE
 OR FLOWERING TREES REQUIRED BY THIS ARTICLE. THE
 LANDSCAPE CALCULATIONS ARE INCORRECT AND THE PALM
 SUBSTITUTION WAS NOT CALCULATED.
  
 5. PROVIDE IRRIGATION IN THE RIGHT-OF-WAY.
  
 6. PROVIDE CITY APPROVED STRIPING DETAIL ON SITE PLAN.
  
 7. CURBING CAN BE USED INSTEAD OF CAR STOPS FOR THE TWO
 ON-SITE PARKING STALLS. THE CURBING CAN REPLACE THE CAR
 STOPS WITH THE CAR OVERHANG AREA BEING CONVERTED INTO
 GREEN SPACE. NO PLANT OR TREE CAN BE PLANTED WITHIN THE
 OVERHANG AREA BUT THE THREE FOOT GREEN SPACE WOULD BE
 EXPANDED TO FIVE FEET TO ALLOW FOR THE ROOTS OF THE
 TREES TO HAVE ROOM TO GROW.
  
 8. PURSUANT TO 94-443 (C)(5)(A), LANDSCAPE AREAS SHALL
 BE SEPARATED FROM VEHICULAR USE AREAS BY NONMOUNTABLE,
 CONCRETE CURBING OF THE TYPE CHARACTERIZED AS "TYPE D".
  
 9. ALL OVERHEAD LINES, UTILITIES, STREET LIGHTS AND
 ANYTHING ELSE THAT MAY INTERFERE WITH THE PROPOSED
 LANDSCAPING SHALL BE SHOWN ON THE LANDSCAPE PLAN TO
 AVOID CONFLICTS.
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT
 KUSSNER @ (561) 822-1462.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2010-05-17 Cont ID  
Sent By hmoser Date 2010-05-17 Time 14:40 Rev Time 0.00
Received By hmoser Date 2010-05-17 Time 14:39 Sent To  
Notes
2010-05-17 14:50:06PASS PROVISO .
 1) FRESH AIR CALCULATIONS DO NOT MATCH ASHRAE 62.
 2) PLEASE PROVIDE A DETAIL ON THE CURB TIE DOWN .
 3) PLEASE REFER TO SECTION 301.21 WIND RESISTANCE ON
 THE A/C UNIT 2007 FBC (M) .
 PLAN REVIEW BY HAROLD MOSER 561-805-6732

Review Stop P PLUMBING
Rev No 1 Status N Date 2010-05-17 Cont ID  
Sent By lwagner Date 2010-05-17 Time 14:45 Rev Time 0.00
Received By lwagner Date 2010-05-17 Time 14:45 Sent To  
Notes
2010-05-17 14:48:37PLUMBING REMOVED. SEE PLUMBING PERMIT #09010345.
  

Review Stop Z ZONING
Rev No 3 Status P Date 2010-05-17 Cont ID  
Sent By lmartine Date 2010-05-17 Time 14:52 Rev Time 0.00
Received By lmartine Date 2010-05-03 Time 15:59 Sent To  
Notes
2010-05-17 14:56:58AMY STELLY
 PLANNING AND ZONING
 561-822-1442
  
 PASSED W/ PROVISO
  
 APPLICANT HAS SIGNED A NOTARIZED STATEMENT AGREEING TO
 THE FOLOWING:
 THE CERTIFICATE OF OCCUPANCY (CO) WILL NOT BE ISSUED
 UNTIL THE SHARED PARKING AGREEMENT IS APPROVED BY THE
 CITY COMMISSION.
2010-05-03 16:00:55PER AMY AND LUIS, CITY COMMISION APPROVAL REQUIRED.

Review Stop Z ZONING
Rev No 2 Status P Date 2010-04-30 Cont ID  
Sent By lmartine Date 2010-04-30 Time 08:54 Rev Time 0.00
Received By lmartine Date 2010-04-30 Time 08:54 Sent To  
Notes
2010-04-30 08:56:13SEE NOTES ON LANDSCAPE REVIEW

Review Stop Z ZONING
Rev No 1 Status F Date 2009-10-20 Cont ID  
Sent By astelly Date 2009-10-20 Time 08:53 Rev Time 0.00
Received By astelly Date 2009-10-20 Time 08:53 Sent To B
Notes
2009-10-20 08:56:16AMY STELLY
 PLANNING AND ZONING
 822-1442
  
  
 ALL LANDSCAPE COMMENTS MUST BE SATISFIED
  