Plan Review Details - Permit 09090220
Plan Review Stops For Permit 09090220
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2009-09-28 Cont ID  
Sent By jwitmer Date 2009-09-28 Time 14:43 Rev Time 1.50
Received By jwitmer Date 2009-09-28 Time 14:43 Sent To  
Notes
2009-09-28 14:49:18AS PER THE MEETING WITH KEITH SPINA THE 14TH FLOOR
 ELEVATOR DOORS ARE TO REMAIN. BO DOUG WISE WILL DO
 ADDITIONAL RESEARCH TO INVESTIGATE THE HISTORY ON
 ELEVATOR LOBBY REQUIREMENTS PER 707.14.1.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2009-09-17 Cont ID  
Sent By jwitmer Date 2009-09-17 Time 16:18 Rev Time 0.44
Received By jwitmer Date 2009-09-17 Time 16:10 Sent To  
Notes
2009-09-17 16:37:43BUILDING PLAN REVIEW
 PERMIT: 09090220
 ADD: 515 N FLAGLER DR 14TH & 15TH FLOOR/ DEMO
 CONT: FISHER CONTRACTING CORP
 TEL: (561)691-4716
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
 1) SHEET D-1.0 14TH FLOOR DEMO INDICATES THE REMOVAL OF
 ELEVATOR LOBBY DOORS. UNDER THE 2007 FBC/ 2009
 SUPPLEMENTS SECTION 707.14.1 ELEVATOR LOBBIES WOULD BE
 REQUIRED IF THEY ARE ALREADY INSTALLED. THE OTHER
 OPTION IS TO SEE IF THE DESIGNER OF RECORD WOULD LIKE
 TO MEET ONE OF THE EXCEPTIONS OR LOOK INTO OTHER SMOKE
 CONTAINMENT POSSIBLIITIES UNDER SECTION 104.11
 ALTERNATE MATERIALS, DESIGN AND METHODS OF CONSTRUCTION
 AND EQUIPMENT.
  
  
 NOTE: A MEETING IS SET WITH KEITH SPINA FOR MONDAY SEPT
 28/ 2009 @ 1:30PM TO DISCUSS EXISTING ELEVATOR LOBBIES
 AND EXCEPTIONS AND OR ALTERNATIVE
 MATERIALS AND METHODS PER 104.11.
  
 STARTING AUGUST 21, 2009, THE CONSTRUCTION SERVICES
 DEPARTMENT WILL BE CLOSED ON FRIDAYS UNTIL FURTHER
 NOTICE.
  
 OPENING HOURS MONDAY - THURSDAY WILL REMAIN AT 8:00 AM
 - 5:00 PM.
  
 JIM WITMER C. B. O.
 COMMERCIAL COMBINATION PLAN REVIEW
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
 SURVEY:
 WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2009-09-16 Cont ID  
Sent By dpalmer Date 2009-09-16 Time 16:23 Rev Time 0.00
Received By dpalmer Date 2009-09-16 Time 16:22 Sent To  
Notes
2009-09-16 16:33:49ELECTRICAL SUB PERMIT REQUIRED BEFORE DEMO TO SAFE OFF
 ALL ELECTRICAL SYSTEMS.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2009-09-23 Cont ID  
Sent By mawillia Date 2009-09-23 Time 14:27 Rev Time 0.00
Received By mawillia Date 2009-09-23 Time 14:00 Sent To  
Notes
2009-09-23 14:19:51*****APPROVED*****
  
 PLAN SHEETS D-1.0 AND D-2.0 WERE STAMPED, INITIALED,
 AND DATED.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-09-23 Cont ID  
Sent By mawillia Date 2009-09-23 Time 14:20 Rev Time 0.00
Received By mawillia Date 2009-09-15 Time 08:34 Sent To  
Notes
2009-09-15 08:34:03SENT TO B-10.

Review Stop P PLUMBING
Rev No 1 Status P Date 2009-09-17 Cont ID  
Sent By kstevens Date 2009-09-17 Time 12:42 Rev Time 0.00
Received By kstevens Date 2009-09-17 Time 12:42 Sent To  
Notes
2009-09-17 12:43:34DEAD ENDS PROHIBITED. SECTION 704.5. (SEE DEMO KEY NOTE
 #6).

Review Stop Z ZONING
Rev No 1 Status N Date 2009-09-22 Cont ID  
Sent By aaponte Date 2009-09-22 Time 09:38 Rev Time 0.00
Received By aaponte Date 2009-09-22 Time 09:38 Sent To  
Notes
***NONE***