Plan Review Stops For Permit 09090068 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2009-11-10 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2009-11-10 |
Time |
16:26 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2009-11-10 |
Time |
14:44 |
Sent To |
PC |
|
Notes |
2009-11-10 16:27:10 | BUILDING REVIEW APPROVED WITH PROVISO: | | | | 1-PROVIDE PRODUCT APPROVALS (2 COPIES) AS REQUIRED BY | | DCA RULE 9B-72 FOR: | | A) ALL INSWING AND OUTSWING DOORS AS SHOWN ON PLANS. | | ENGINEERING SUBMITTED IS NOT A PRODUCT APPROVAL. | | B) WATER PROOF MEMBRANE OVER FOR SECOND FLOOR PORCH | | THAT IS DESIGNED TO RECEIVE THE PROPOSED FINISH FLOOR. | | C) ARCHITECT OF RECORD TO REVIEW AND APPROVE ALL | | PRODUCT APPROVALS IN WRITING PRIOR TO SUBMITTAL. SEC. | | 106.3.3 CITY AMENDMENTS TO FBC. | | | | 2- REVISE DESIGN PRESSURES FOR DOOR/WINDOWS SHOWN ON | | SHEET A-2. SEE DESIGN LOADS ON SHEET S-2 AND REVISE AS | | REQUIRED. | | | | 3- REVISE FLOOR LOADS SHOWN ON SHEET S-1. SEE TABLE | | R301.5 OF 2007 FL. RESIDENTIAL CODE AND REVISE AS | | REQUIRED. | | | | 4- SPECIFY FINISH FLOOR AT BALCONY (COORDINATE WITH | | ITEM #1B) ABOVE. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2009-09-23 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2009-09-22 |
Time |
17:03 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2009-09-22 |
Time |
17:03 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
N |
Date |
2009-11-10 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-11-10 |
Time |
14:19 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-11-10 |
Time |
14:19 |
Sent To |
|
|
Notes |
2009-11-10 14:20:08 | ALL ELECTRICAL REVIEWS AND PERMITS WERE REVIEWED AND | | ISSUED BY BILL TROBAUGH UNDER SEPARATE PERMITS. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2009-09-17 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-09-17 |
Time |
09:52 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-09-17 |
Time |
09:52 |
Sent To |
|
|
Notes |
2009-09-17 09:52:36 | | | ** DENIED PLANS ** | | | | | | 1) NOTE: PLEASE SEE FBC R313.1. PLEASE SHOW A LAYOUT | | ALL EXISTING OR NEW SMOKE ALARMS MEETING CURRENT | | NFPA-72 11.8.3, 11.5.1. MUST BE HARDWIRED WITH BATTERY | | BACK UP. MUST BE INSIDE AND OUTSIDE ALL SLEEPING ROOMS | | AND AT LEAST ONE ON FIRST FLOOR LEADING TO FLOOR ABOVE. | | PLEASE ALSO SEE FS 553.885 AS A CARBON MONOXIDE | | DETECTOR IS REQUIRED FOR HOME WITH THE NEW GAS | | APPLIANCES. | | | | 2) NOTE: PLANS DO NOT INDICATE ANY CIRCUITS FOR NEW AND | | EXISTING REQUIRED DEDICATED CIRCUITS IN KITCHEN | | REMODEL. | | PLEASE SUBMIT A PANEL SCHEDULE SHOWING THE MINIMUM | | CIRCUITS PER 210.52B1, 210.11C1, 220.52 | | PLEASE BE SURE TO INCLUDE MINIMUM CONDUCTORS AND OVER | | CURRENT PROTECTION. | | PLEASE SEE 240.4,310.16 AND 408.4 FOR CONDUCTORS, | | SIZING OF BREAKERS AND PANEL SCHEDULE. | | | | 3) NOTE: PLANS STATE COMPLIANCE WITH NEC. HOWEVER THE | | EDITION OF THE PERMITTED SCOPE OF WORK IS UNDER THE | | 2005 NEC. ( NFPA-70) | | | | | | | | | | ** AS STATED ABOVE. PLEASE CALL TO GO OVER ANY | | COMMENTS. | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | CONTACT THIS REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2009-09-02 |
|
|
Cont ID |
|
Sent By |
swurafti |
Date |
2009-09-02 |
Time |
16:17 |
Rev Time |
0.00 |
Received By |
swurafti |
Date |
2009-09-02 |
Time |
16:17 |
Sent To |
|
|
Notes |
2009-09-02 16:17:41 | HISTORIC APPROVED BY JPAPA |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2009-11-03 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2009-11-03 |
Time |
10:43 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2009-11-03 |
Time |
10:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2009-09-23 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2009-09-23 |
Time |
09:51 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2009-09-03 |
Time |
15:01 |
Sent To |
|
|
Notes |
2009-09-03 15:15:57 | SENT TO R-8. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2009-09-22 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2009-09-22 |
Time |
16:58 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2009-09-22 |
Time |
16:58 |
Sent To |
|
|
Notes |
2009-09-22 16:59:16 | NO A/C WORK. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2009-11-06 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2009-11-06 |
Time |
15:21 |
Rev Time |
0.00 |
Received By |
eschneid |
Date |
2009-11-06 |
Time |
15:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2009-09-18 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2009-09-18 |
Time |
16:33 |
Rev Time |
0.50 |
Received By |
eschneid |
Date |
2009-09-18 |
Time |
16:33 |
Sent To |
|
|
Notes |
2009-09-18 17:02:05 | FAILED | | | | 1) THE NEW EXTENDED SLAB AND STEPS ARE NOT SHOWN ON THE | | PROPOSED SITE PLAN. PLEASE INCLUDE THE DIMENSIONS OF | | THE SLAB AND STEPS AND THE SETBACK TO THE SOUTH AND | | EAST PROPERTY LINES. | | | | 2) THE NEW ROOF IS NOT ACCURATELY SHOWN ON THE PROPOSED | | SITE PLAN. | | | | 3) THE EXISTING COVERED ENTRY IS NOT SHOWN ON THE | | PROPOSED SITE PLAN. THE PROPOSED ELEVATIONS SHOW THAT | | IT IS TO REMAIN. | | | | 4) THE PROPOSED SITE PLAN SHOWS THE DRIVEWAY BEING | | EXTENDED. THIS IS NOT INDICATED ON THE SCOPE OF WORK ON | | THE PERMIT. | | | | 5) THE NEW COLUMNS AND THE RAILING ARE BEING SHOWN | | WITHIN THE REQUIRED 15 FOOT EAST SETBACK. THE PLANS | | SHALL BE REVISED TO MOVE THE COLUMNS AND THE RAILING. | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. |
|
|