2009-09-03 12:21:00 | 2007 FBC W/2009 REVISIONS |
| LEVEL 2 ALTERATION |
| |
| DENIED BY BUILDING |
| |
| 1) BEFORE A PERMIT TO CONSTRUCT CAN BE |
| ISSUED, IMPACT FEES MUST BE PAID TO |
| PALM BEACH COUNTY. THE PLANS MUST BE |
| STAMPED AND THE RECEIPT ATTACHED TO THE |
| APPLICATION. 233-5025 |
| |
| 2) THE PLANS INDICATE THAT THE STORAGE AREA IS TO BE |
| CONDITIONED SPACE ADDED TO THE EXISTING CONDITIONED |
| SPACE AND SHARING THE EXISTING MECHANICAL SYSTEM. |
| SUBMIT ENERGY CALCULATIONS AS REQUIRED BY 2007 FBC |
| ENERGY GLITCH AMENDMENTS. N1100.0 |
| |
| 3) SPECIFY THE R-VALUE OF THE INSULATION THAT WILL BE |
| INSTALLED ON THE EXTERIOR BLOCK WALL AND IN THE CEILING |
| ABOVE THE ROOM. |
| |
| 4) SPECIFY THE SIZE AND TYPE OF DOOR THAT WILL BE |
| INSTALL IN THE ADJACENT WALL BETWEEN THE NEW ROOM AND |
| THE UNCONDITIONED GARAGE. SEE N1103.AB |
| |
| 5) THE PLANS INDICATE THAT THE TRACKS FOR THE OVERHEAD |
| DOOR ARE TO BE REMOVED AND THE DOOR IS TO BE CAULKED. |
| PLEASE CLARIFY HOW THE DOOR WILL REMAIN AS A COMPONENT |
| TO RESIST THE WIND LOADS AT THE OPENING OR IS THE NEW |
| WALL INTENDED TO RESIST THE WIND LOADS. IF THE NEW WALL |
| INTENDED TO RESIST WIND FORCES, PROVIDE A DETAILED WALL |
| SECTION AND SHOW ALL CONNECTIONS FOR WIND LOAD |
| RESISTANCE. |
| |
| 6) WALL SECTION A SPECIFIES 25 GAUGE STEEL STUDS. |
| INDICATE HOW THE METAL TRACK WILL BE ATTACHED TO THE 2 |
| X 4 WOOD PLATES AT THE TOP AND BOTTOM. |
| |
| 7) SPECIFY THE LEVEL OF ALTERATION ON THE PLANS AS |
| REQUIRED BY THE 2007 FBC EXISTING BUILDING CODE. |
| |
| 8) IF THE OVERHEAD GARAGE DOOR IS MODIFIED SUCH THAT IT |
| IS NO LONGER TO BE USED TO RESIST WIND PRESSURES AS |
| TESTED. SPECIFY THE WIND SPEED, EXPOSURE CATEGORY (AS |
| REVISED IN THE 2007 FBC) AND WIND LOAD PRESSURES AT THE |
| OPENING. |
| |
| 9) PROVIDE DIMENSIONS OF THE ROOM ON THE FLOOR PLANS. |
| |
| ROBERT MCDOUGAL |
| BLDG. PLAN REVIEW |
| (561)805-6714 |
| [email protected] |