Plan Review Details - Permit 09080776
Plan Review Stops For Permit 09080776 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2009-10-28 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2009-10-28 |
Time |
09:57 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2009-10-28 |
Time |
09:57 |
Sent To |
|
|
Notes |
2009-10-28 14:27:01 | ****PASSED W/REDLINE**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBC FLORIDA BUILDING CODE 2007 WITH 2009 SUPPLEMENTS | | FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING | | CODE | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | FAC FLORIDA ADMINISTRATIVE CODE | | FS FLORIDA STATUTE | | | | 1. FROM PREVIOUS TWO COMMENT LISTS, SHEATHING NAILING | | DOES NOT COMPLY WITH FBC R803.2.3.1, SHEET 2, VARIOUS | | DETAILS. ZONE 3 REQUIRES 4" AT EDGES, PLAN SPECIFIES | | 6". THIS IS PRESCRIPTIVE IN THE CODE AND CANNOT BE | | REDUCED. | | | | THE DETAILS ON SHEET 2 SPECIFY 30# FELT; THE PRODUCT | | APPROVAL SUBMITTED DOES NOT ALLOW 30#. PLEASE EITHER | | REMOVE FROM THE DETAIL OR REVISE SO THAT IT IS | | CONSISTENT WITH OTHER DETAILS. | | | | PLANS HAVE BEEN REDLINED; THE NON CODE COMPLIANT DETAIL | | HAS BEEN REMOVED. 4"/6" ROOF SHEATHING REQUIRED | | | | 2. ROOF PERMIT REQUIRED. FOR A ROOF PERMIT, ENHANCED | | FASTENING CALCULATIONS REQUIRED PER NOA 08-0221.11, SEE | | GENERAL LIMITATION #7. THIS MAY BE SUBMITTED SEPARATELY | | WITH THE ROOF PERMIT APPLICATION. APPROVED ASSEMBLY | | MUST BE SELECTED AND ENHANCED FASTENING PATTERN | | SUBMITTED PRIOR TO ROOF PERMIT ISSUANCE. | | | | REGARDING THE ROOF DOCUMENTS SUBMITTED: | | | | A. ENGINEERING SPECIFIES EXPOSURE B. | | B. THE NOA SUBMITTED IS FOR "RECOVER DECKS." THIS IS | | FOR RECOVER APPLICATION, NOT NEW CONSTRUCTION. SUBMIT | | THE APPROPRIATE NOA. | | C. AN APPROVED ASSEMBLY MUST BE SELECTED. IT IS NOT | | CLEAR HOW THE ENGINEER HAS DETERMINED ROOF FASTENER | | SPACING, MUST DO CALCULATIONS IN ACCORDANCE WITH | | RAS117. IT APPEARS THAT HE HAS ROUNDED UP, FROM 5.9" TO | | 6", BUT SEE RAS117 WHICH SPECIFICALLY STATES THAT | | FASTENING MUST BE ROUNDED DOWN TO THE NEAREST INCH. | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2009-09-14 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2009-10-22 |
Time |
09:22 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2009-09-14 |
Time |
16:07 |
Sent To |
Z |
|
Notes |
2009-09-14 16:26:46 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBC FLORIDA BUILDING CODE 2007 WITH 2009 SUPPLEMENTS | | FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING | | CODE | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | FAC FLORIDA ADMINISTRATIVE CODE | | FS FLORIDA STATUTE | | | | 1. THIS PROPERTY IS LOCATED IN EXPOSURE C, SEE | | ASCE7-05. EITHER REVISE EXPOSURE AND DESIGN OR PROVIDE | | RATIONALE FOR EXPOSURE B. FBC R301 | | | | 2. PLEASE EXPLAIN DESIGN PRESSURES; FOR INSTANCE, ROOF | | ZONE 3, 10SF, -68.1 PSF. FBC R301 | | | | 3. WIND DESIGN INFORMATION, REFERENCE TO 3 SECOND | | "BURST," PLEASE CLARIFY, DO YOU MEAN "GUST?" SEE | | FBC1609, FBC R301, ASCE7-05. | | | | 4. SHEATHING NAILING DOES NOT COMPLY WITH FBC | | R803.2.3.1, SHEET 2, VARIOUS DETAILS. | | | | 5. FLORIDA STATE OR LOCAL PRODUCT APPROVAL OR NOA | | REQUIRED FOR HARDIBOARD SIDING. | | | | 6. ROOF PERMIT REQUIRED. FOR A ROOF PERMIT, ENHANCED | | FASTENING CALCULATIONS REQUIRED PER NOA 08-0221.11, SEE | | GENERAL LIMITATION #7. THIS MAY BE SUBMITTED SEPARATELY | | WITH THE ROOF PERMIT APPLICATION. APPROVED ASSEMBLY | | MUST BE SELECTED AND ENHANCED FASTENING PATTERN | | SUBMITTED PRIOR TO ROOF PERMIT ISSUANCE. | | | | 7. ADDITIONAL FEES DUE (VALUATION ADJUSTMENT, ICC | | TABLE, TYPE V, UTILITY, $37.87/SF). PLEASE PAY PRIOR TO | | RESUBMITTAL (CAN BE PAID ONLINE). | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2009-10-19 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-10-19 |
Time |
14:15 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2009-10-19 |
Time |
14:15 |
Sent To |
Z |
|
Notes |
2009-10-22 09:22:14 | 10/22, ROUTED PLANS FROM B2 TO SMH DESK | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2009-09-21 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2009-09-21 |
Time |
15:19 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2009-08-31 |
Time |
15:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2009-10-21 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2009-10-21 |
Time |
15:15 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2009-10-21 |
Time |
15:15 |
Sent To |
B |
|
Notes |
2009-10-21 15:16:52 | ZONING PLAN REVIEW | | | | PERMIT NO.: 09080776 | | ADDRESS: 430 LYTLE STREET | | CONTRACTOR/CONTACT: PETER SEIDLE | | TELEPHONE NO.: 561.596.2766 | | SCOPE OF REVIEW: INSTALLATION OF ACCESSORY SHED. | | | | REVIEW STATUS: PASSED WITH PROVISOS | | | | THIS REVIEW HAS BEEN PASSED SUBJECT TO THE FOLLOWING | | PROVISOS: | | | | 1) PRIOR TO CERTIFICATE OF OCCUPANCY, THE EXISTING | | ABOVE-GROUND POOL SHALL BE REMOVED IN ITS ENTIRETY. | | | | 2) PRIOR TO CERTIFICATE OF OCCUPANCY, THE EXISTING SHED | | SHALL BE REMOVED IN ITS ENTIRETY. | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | JOHN ROACH, SENIOR PLANNER | | CITY OF WEST PALM BEACH | | PLANNING AND ZONING DEPARTMENT | | 401 CLEMATIS STREET - P.O. BOX 3366 | | WEST PALM BEACH, FLORIDA 33402 | | | | PHONE: 561.822.1435 | | FAX: 561.822.1460 | | | | EMAIL: [email protected] | | | | WWW.CITYOFWPB.COM | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2009-09-21 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2009-09-21 |
Time |
08:38 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2009-09-21 |
Time |
08:38 |
Sent To |
|
|
Notes |
2009-09-21 08:48:35 | ZONING PLAN REVIEW | | | | PERMIT NO.: 09080776 | | ADDRESS: 430 LYTLE STREET | | CONTRACTOR/CONTACT: PETER SEIDLE | | TELEPHONE NO.: 561-533-7139 | | SCOPE OF REVIEW: WOOD FRAME SHED. | | | | REVIEW STATUS: FAILED | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | REVIEW COMMENTS: | | | | 1) PLEASE PROVIDE THE SEPARATION DIMENSION BETWEEN THE | | PRIMARY RESIDENCE AND THE PROPOSED SHED. PURSUANT TO | | SECTION 94-304(B)(3) OF THE CITY'S ZONING AND LAND | | DEVELOPMENT REGULATIONS (ZLDRS), ACCESSORY STRUCTURES | | SHALL BE LOCATED NO CLOSER THAN SIX (6) FEET TO THE | | PRIMARY STRUCTURE. | | | | 2) ACCORDING TO THE SURVEY SUBMITTED, ANOTHER ACCESSORY | | STRUCTURE IS ALREADY LOCATED ON THE PROPERTY; THIS | | STRUCTURE IS NOT LOCATED ON THE SITE PLAN. PLEASE | | CLARIFY. IF THE STRUCTURE CURRENTLY EXISTS, PLEASE | | INDICATE IT ON THE SITE PLAN AND LABEL AS "EXISTING". | | | | 3) IF THE STRUCTURE ON THE SURVEY DOES EXIST, PLEASE | | PROVIDE THE TOTAL SQUARE FOOTAGE OF ALL EXISTING | | ACCESSORY STRUCTURES. PURUSANT TO SECTION 94-304(B)(1) | | OF THE CITY'S ZLDRS, THE TOAL AREA OF ALL ROOFED | | ACCESSORY STRUCTURES SHALL NOT EXCEED 75 PERCENT OF THE | | GROSS FLOOR AREA OF THE PRIMARY STRUCTURE, WITH A | | MAXIMUM OF 1,000 SQUARE FEET. | | | | 4) ACCORDING TO THE SURVEY SUBMITTED, THERE IS AN | | EXISTING ABOVE-GROUND POOL. PLEASE CLARIFY AS TO | | WHETHER OR NOT THIS CURRENTLY EXISTS. PURSUANT TO | | SECTION 94-304(D)(1)(B) OF THE CITY'S ZLDRS, | | ABOVE-GROUND POOLS ARE PROHIBITED. IF THE POOL | | CURRENTLY EXISTS, IT SHALL BE REMOVED PRIOR TO THE | | ISSUANCE OF THIS BUILDING PERMIT. | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | JOHN ROACH, SENIOR PLANNER | | CITY OF WEST PALM BEACH | | PLANNING AND ZONING DEPARTMENT | | 401 CLEMATIS STREET - P.O. BOX 3366 | | WEST PALM BEACH, FLORIDA 33402 | | | | PHONE: 561.822.1435 | | FAX: 561.822.1460 | | | | EMAIL: [email protected] | | | | WWW.CITYOFWPB.COM | | |
|
|
|