Plan Review Details - Permit 09080586
Plan Review Stops For Permit 09080586
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2009-09-23 Cont ID  
Sent By jwitmer Date 2009-09-23 Time 09:46 Rev Time 0.25
Received By jwitmer Date 2009-09-23 Time 09:26 Sent To  
Notes
2009-09-23 09:47:51A.1 & LS -2 & LS2.1 TENANT WALL RATING REVISION

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2009-08-27 Cont ID  
Sent By jwitmer Date 2009-08-27 Time 09:00 Rev Time 0.66
Received By jwitmer Date 2009-08-27 Time 08:20 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2009-10-29 Cont ID  
Sent By btrobaug Date 2009-10-29 Time 11:23 Rev Time 0.00
Received By btrobaug Date 2009-10-29 Time 11:22 Sent To  
Notes
2009-10-29 11:23:01 
  
 LOW VOLTAGE VOICE/DATA REVISION PER DOUG./WRT.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2009-08-31 Cont ID  
Sent By dwise Date 2009-08-31 Time 19:16 Rev Time 0.00
Received By dwise Date 2009-08-31 Time 19:16 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2009-09-03 Cont ID  
Sent By mawillia Date 2009-09-03 Time 11:40 Rev Time 0.00
Received By mawillia Date 2009-09-03 Time 11:01 Sent To  
Notes
2009-09-03 11:15:32*****APPROVED*****
  
 THE COMMENTS FROM THE PREVIOUS REVIEW HAVE BEEN
 ADDRESSED; PLAN SHEETS LS-2, LS-2.1, E-3, & FP-1 WERE
 STAMPED, INITIALED, AND DATED.
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722
  
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2009-08-26 Cont ID  
Sent By mawillia Date 2009-08-26 Time 15:20 Rev Time 0.00
Received By mawillia Date 2009-08-26 Time 15:05 Sent To  
Notes
2009-08-26 15:20:36*****PARTIAL APPROVAL*****
  
 1. THE PROJECT SITE ADDRESS, INCLUDING THE SUITE NUMBER
 SHALL BE IN THE TITLE BLOCK OF EACH SUBMITTED PLAN
 SHEET.
  
 2. BE ADVISED OF THE CURRENTLY ADOPTED CODE EDITIONS AS
 FOLLOWS: NFPA 1 -2006 EDITION, NFPA 101 - 2006 EDITION,
 NFPA 241 - 2004 EDITION .......ON SHEET LS-2.1, AMEND
 APPLICABLE CODES
  
 3. ON SHEET LS-2.1, A SMOKE DETECTOR IS SHOWN IN OFFICE
 D2.202 BUT NOT IN OFFICE D2.201; HOWEVER ON SHEET E-3,
 A SMOKE DETECTOR IS SHOWN IN BOTH OF THESE OFFICES.
 THESE SHEETS SHOULD CORRELATE
  
 (PLAN SHEETS LS-2, LS-2.1, E-3, & FP-1 TO BE
 FIRE-STAMPED WHEN THE ABOVE AS WELL AS ANY OTHER PLAN
 EXAMINERS' COMMENTS HAVE BEEN ADDRESSED)
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2009-09-22 Cont ID  
Sent By lmartine Date 2009-09-22 Time 16:41 Rev Time 0.00
Received By lmartine Date 2009-09-22 Time 16:41 Sent To  
Notes
2009-09-22 16:41:46GAVE TO JIM

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-08-31 Cont ID  
Sent By dwise Date 2009-08-31 Time 19:20 Rev Time 0.00
Received By dwise Date 2009-08-27 Time 19:20 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2009-08-31 Cont ID  
Sent By dwise Date 2009-08-31 Time 19:17 Rev Time 0.00
Received By dwise Date 2009-08-31 Time 19:17 Sent To  
Notes
2009-08-31 19:19:35APPROVED WITH PROVISO:
 1. MUST SUBMIT A REVISED MECHANICAL PLAN WHICH INCLUDES
 REQUIRED FIRE DAMPERS TO BE INSTALLED IN RATED WALL
 PENETRATIONS. PLEASE INCLUDE SPECIFICATIONS AND
 INSTALLATION DETAILS FOR THE DAMPERS SPECIFIED WHICH
 ARE STAMPED "APPROVED AS NOTED" BY THE DESIGN
 PROFESSIONAL.

Review Stop P PLUMBING
Rev No 1 Status N Date 2009-08-31 Cont ID  
Sent By dwise Date 2009-08-31 Time 19:20 Rev Time 0.00
Received By dwise Date 2009-08-31 Time 19:19 Sent To  
Notes
***NONE***