Plan Review Stops For Permit 09080125 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2009-09-03 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2009-09-03 |
Time |
07:44 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2009-09-03 |
Time |
07:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2009-08-14 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2009-08-14 |
Time |
18:17 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2009-08-14 |
Time |
18:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2009-09-02 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2009-09-02 |
Time |
17:30 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2009-09-02 |
Time |
17:00 |
Sent To |
B |
|
Notes |
2009-09-02 17:30:49 | TO SAMANTHA./WRT. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2009-08-17 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2009-08-17 |
Time |
13:33 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2009-08-17 |
Time |
12:00 |
Sent To |
|
|
Notes |
2009-08-17 13:33:03 | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | THE 2007 FLORIDA BUILDING CODE, 2009 REVISIONS, 2005 | | NEC, 2004 FBC AS AMENDED, CHAPTER 1.AND FOUND | | NONCOMPLIANT WITH THE FOLLOWING: | | | | 1} THE SQUARE FOOTAGE AND LIGHTING POWER COMPLIANCE IN | | THE FLA/COM AND THE LIGHTING PERFORMANCE CALCULATIONS | | ON SHEET E-1.1DO NOT CORRELATE. 13-415,AB,5. THE DESIGN | | WATTS ARE OVER THE ALLOWABLE WATTS IN THE LIGHTING | | PERFORMANCE CALCULATION, SHEET E-1.1. | | | | 2} 240.24(D) NOT IN VICINITY OF EASILY IGNITIBLE | | MATERIAL OVERCURRENT DEVICES SHALL NOT BE LOCATED IN | | THE VICINITY OF EASILY IGNITIBLE MATERIAL, SUCH AS IN | | CLOTHES CLOSETS. | | EXAMPLES OF LOCATIONS WHERE COMBUSTIBLE MATERIALS MAY | | BE STORED ARE LINEN CLOSETS, PAPER STORAGE CLOSETS, AND | | CLOTHES CLOSETS.INDICATE WHAT MATERIALS ARE INTENDED TO | | BE STORED IN ROOM 105. ALSO SEE 110.26. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2009-09-02 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2009-09-02 |
Time |
13:38 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2009-09-02 |
Time |
13:13 |
Sent To |
|
|
Notes |
2009-09-02 13:37:49 | *****APPROVED***** | | | | | | PLAN SHEETS A-1.1, A-2.1, E-1.1, AND FP-1 WERE STAMPED, | | INITIALED, AND DATED. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2009-08-18 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2009-08-18 |
Time |
12:43 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2009-08-18 |
Time |
12:19 |
Sent To |
|
|
Notes |
2009-08-18 12:39:55 | *****FIRE-STAMPING NEEDED***** | | | | THE APPROPIATE PLAN SHEETS TO BE FIRE-STAMPED WHEN THE | | OTHER PLAN REVIEWER(S)' COMMENTS HAVE BEEN ADDRESSED. | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2009-09-01 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2009-09-01 |
Time |
11:15 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2009-09-01 |
Time |
11:15 |
Sent To |
|
|
Notes |
2009-09-02 13:02:02 | ************$$EXPEDITED$$******************* | 2009-09-01 11:16:25 | SENT TO B-6. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2009-08-18 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2009-08-18 |
Time |
12:40 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2009-08-07 |
Time |
16:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2009-08-15 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2009-08-15 |
Time |
16:41 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2009-08-15 |
Time |
16:41 |
Sent To |
|
|
Notes |
2009-08-15 16:42:09 | RETURN AIR TRANSFER DUCT IN OFFICE SHALL BE MIN. 13" | | ROUND PER FBC-M 601.4. | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | RONALD J. REGUEIRO | | 561.805.6719 | | [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2009-08-14 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2009-08-14 |
Time |
17:26 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2009-08-14 |
Time |
17:26 |
Sent To |
|
|
Notes |
|
|