Plan Review Details - Permit 09080114
Plan Review Stops For Permit 09080114
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2009-08-24 Cont ID  
Sent By jwitmer Date 2009-08-24 Time 09:25 Rev Time 0.25
Received By jwitmer Date 2009-08-24 Time 09:05 Sent To  
Notes
2009-08-24 09:26:20REVISION:
 TRAVEL DISTANCE
 MATERIAL SPECS

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2009-08-11 Cont ID  
Sent By jwitmer Date 2009-08-11 Time 12:15 Rev Time 0.77
Received By jwitmer Date 2009-08-11 Time 11:21 Sent To  
Notes
2009-08-11 12:14:55BUILDING PLAN REVIEW
 PERMIT: 09080114
 ADD: 223 CLEMATIS ST.
 CONT: PAUL DAVIS CONSTRUCTION
 TEL: (561)718-8161
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 AUGUST 11/2009 1ST REVIEW
  
 BUILDING PROVISO:
  
 1) PLANS INDICATE A TRAVEL DISTANCE OF 75'-6" FROM THE
 BOOTH FURTHEST FROM THE ENTRY AND CHOICE OF TO MEANS OF
 EGRESS, PLEASE SUBMIT A REVISION COMPLYING WITH:
 1014.4.3.3 TABLE AND SEATING AISLE ACCESS WAY LENGTH.
 THE LENGTH OF TRAVEL ALONG THE AISLE ACCESS WAY SHALL
 NOT EXCEED 30 FEET (9144 MM) FROM ANY SEAT TO THE POINT
 WHERE A PERSON HAS A CHOICE OF TWO OR MORE PATHS OF
 EGRESS TRAVEL TO SEPARATE EXITS.
  
 2) GENERAL NOTE# 11 INDICATES THAT CONTRACTOR TO SUBMIT
 TO THE ARCHITECT OF RECORD DOCUMENTATION FOR FLAME
 SPREAD AND SMOKE DEVELOPMENT ON DRAPERIES, SEATING
 (BUILT INS) AND OTHER ITEMS BEFORE SUBMITTAL TO THE
 BUILDING DEPARTMENT.
  
 3) GC TO PROVIDE AN INCRASED VALUE FOR BUILT INS.
  
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
 SURVEY:
 WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2009-08-20 Cont ID  
Sent By mawillia Date 2009-08-20 Time 12:17 Rev Time 0.00
Received By mawillia Date 2009-08-20 Time 11:56 Sent To B
Notes
2009-08-20 12:09:38*****APPROVED*****
  
 PLAN SHEET A-1 (OF 1) STAMPED, INITIALED,AND DATED.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-08-20 Cont ID  
Sent By jwitmer Date 2009-08-20 Time 16:12 Rev Time 0.00
Received By jwitmer Date 2009-08-07 Time 16:27 Sent To  
Notes
2009-08-07 16:27:26B-11

Review Stop Z ZONING
Rev No 1 Status N Date 2009-08-18 Cont ID  
Sent By aaponte Date 2009-08-18 Time 16:05 Rev Time 0.00
Received By aaponte Date 2009-08-18 Time 16:05 Sent To  
Notes
2009-08-18 16:05:39ALL INTERIOR CHANGES.