Plan Review Details - Permit 09070391
Plan Review Stops For Permit 09070391
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2009-09-09 Cont ID  
Sent By jwitmer Date 2009-09-09 Time 15:50 Rev Time 0.33
Received By jwitmer Date 2009-09-09 Time 15:30 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2009-07-24 Cont ID  
Sent By jwitmer Date 2009-07-24 Time 15:06 Rev Time 0.55
Received By jwitmer Date 2009-07-24 Time 14:30 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By btrobaug Date 2009-10-29 Time 16:05 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2009-09-20 Cont ID  
Sent By dpalmer Date 2009-09-20 Time 09:36 Rev Time 0.00
Received By dpalmer Date 2009-09-20 Time 09:11 Sent To PC
Notes
2009-09-20 09:36:51** PROVISO/ REVISION REQUIRED **
  
 PLANS ARE REQUIRED TO BE REVISED BEFORE ROUGH
 ELECTRICAL INSPECTION.
  
  
 1) NOTE: ALL EMERGENCY/EXIT LIGHTS SHALL BE CIRCUITED
 TO LOCAL LIGHTING BRANCH CIRCUIT PER 700.12F. AS SHOWN
 ON PLANS, THE CIRCUITING DOES NOT MEET THE EXCEPTION IN
 THE NEC. SHOWN ON A NEW CIRCUIT #5, WHEN THEY ARE
 REQUIRED TO BE SPLIT BETWEEN #6 AND #8.
  
 2) NOTE: AUTOMATED LIGHTING CONTROLS FOR NEW BEING
 INSTALLED IS REQUIRED FOR NEW OFFICE AREA. PLEASE SEE
 13-415.AB.1.1,.1.2. THIS IS A BUILDING BY DEFINITION
 GREATER THAN 5K SQ FT.
  
 3) NOTE: EXTERIOR LIGHTING CONTROL SHALL MEET
 13-415.AB.1.4. PLANS INDICATE A SINGLE POLE SWITCH
 WHICH IS NOT PERMITTED. THE CODE REQUIRES ONE OF THE
 METHODS NOTED IN SECTION GIVEN. THIS HAS NOTHING TO DO
 WHETHER OR NOT THE BUILDING IS GREATER THAN 5K SQ FT.
  
 4) NOTE: PLEASE ACCURATELY SHOW THE ENTIRE ELECTRICAL
 SERVICE OF THE BUILDING. SERVICE AS SHOWN IS NOT
 ACCURATE FOR ENTIRE SERVICE ON BUILDING.
  
 5) NOTE: FIXTURES ON PLANS NEED TO BE SPECIFIC IN ORDER
 TO VERIFY 13-415.AB.5. STATING A 2X4 FIXTURE COULD MEAN
 THE FIXTURE COULD BE 30VA,32VA, 56VA, 58VA, 60VA, 64VA
 OR MORE. THE LPD SHOWN ON PLANS CAN NOT BE CONFIRMED AS
 MEETING THE MAXIMUM ALLOWANCES.
  
  
 ** LOW VOLTAGE SYSTEMS, INCLUDING FIRE ALARMS ARE NOT
 INCLUDED. SEPARATE PERMITS AS INDICATED ON PLANS
 REQUIRED.
  
  
  
 IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT
 TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO
 CONTACT THIS REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2009-07-29 Cont ID  
Sent By btrobaug Date 2009-07-29 Time 12:12 Rev Time 0.00
Received By btrobaug Date 2009-07-29 Time 12:04 Sent To  
Notes
2009-07-29 16:23:38 
 PROVISO
  
 THE PLANS ARE INCOMPLETE. PLEASE RESUBMIT A REVISION
 SHOWING ACTUAL CONDITIONS PRIOR TO CALLING ROUGH
 ELECTRICAL INSPECTION. THE REVIEWED PLAN MUST BE ON THE
 JOB SITE AT TIME OF INSPECTION. ALLOW AT LEAST ONE WEEK
 (PER TRADE) FOR PLAN REVIEW.
  
 1} THE EM LIGHTS MUST BE SHOWN WIRED TO THE LOCAL
 BRANCH CIRCUIT, 700.12(F)(4).
  
 2} SHOW THE LOCATION OF THE A/C EQUIPMENT ON THE PLAN.
 ALSO SHOW COMPLIANCE WITH THE REQUIRED DISCONNECT PER
 440.14, RECEPTACLE PER 210.63.
  
 3} A RECEPTACLE PER 210.63 IS REQUIRED ON THE ROOF.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2009-09-15 Cont ID  
Sent By mawillia Date 2009-09-15 Time 13:04 Rev Time 0.00
Received By mawillia Date 2009-09-15 Time 12:54 Sent To  
Notes
2009-09-15 13:04:29*****APPROVED*****
  
 THE COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEW HAVE
 BEEN ADDRESSED; PLAN SHEETS A-2 AND E-1 WERE STAMPED,
 INITIALED, AND DATED.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2009-08-05 Cont ID  
Sent By mcarsill Date 2009-08-05 Time 13:03 Rev Time 0.00
Received By mcarsill Date 2009-08-05 Time 12:48 Sent To  
Notes
2009-08-05 13:03:531650 MERCER AVENUE
 BUILD INTERIOR OFFICE SPACE WITH BATHROOM, PER PLAN.
  
 1. ONE EXIT SIGN FROM OFFICE LEADS YOU TO THE EXISTING
 STORAGE AREA.
  
 2. PLEASE EXPLAIN EXITING FROM THE BUILDING. IT APPEARS
 THAT ONLY ONE EXTERIOR SWINGING DOR EXISTS. PLEASE
 INDICATE HOW MEANS OF EGRESS PER INDUSTRIAL OCCUPANCIES
 40.2.4.1.1 IS ACHEIVED.
  
 3. SEPARATE PLANS AND PERMITS REQUIRED FOR FIRE
 SPRINKLER REMODEL.
  
 4. PLEASE ILLUSTRATE ALL FIRE AND LIFE SAFETY SYSTEMS
 AND DEVICES WITHIN THE BUILDING. THESE INCLUDE EXIT
 DOORS, EMERGENCY LIGHTS, PORTABLE FIRE EXTINGUISHER,
 ETC. PLEASE INDICATE CODE PROVISIONS THAT ALLOWS
 VERTICAL ROLLING DOORS TO BE USED AS EXITS.
  
 5. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY
 WITH NFPA 241.
  
 DENIED
  
  
 MIKE CARSILLO, BATTALION CHIEF
 BUREAU OF FIRE PREVENTION

Review Stop I INCOMING/PROCESSING
Rev No 3 Status   Date 2009-10-22 Cont ID  
Sent By btrobaug Date 2009-10-22 Time 09:09 Rev Time 0.00
Received By btrobaug Date 2009-10-22 Time 09:09 Sent To  
Notes
2009-10-22 09:10:34TO ME./WRT.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2009-08-31 Cont ID  
Sent By lmartine Date 2009-08-31 Time 14:59 Rev Time 0.00
Received By lmartine Date 2009-08-31 Time 14:58 Sent To  
Notes
2009-08-31 15:23:52B-4

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-08-10 Cont ID  
Sent By kstevens Date 2009-08-10 Time 10:04 Rev Time 0.00
Received By kstevens Date 2009-07-16 Time 10:04 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2009-09-08 Cont ID  
Sent By rregueir Date 2009-09-08 Time 16:43 Rev Time 0.00
Received By rregueir Date 2009-09-08 Time 16:34 Sent To  
Notes
2009-09-08 16:43:41MINI-SPLIT REMOVED, REPLACED WITH PROTABLE WALL UNIT
 A/C. EXHAUST FAN IS ONLY MECHANICAL SCOPE.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2009-07-29 Cont ID  
Sent By rregueir Date 2009-07-29 Time 14:20 Rev Time 0.00
Received By rregueir Date 2009-07-29 Time 13:38 Sent To  
Notes
2009-07-29 14:20:55REVIEW #: 1ST
 ACTION: DENIED
  
 FBC 2007 CODE FAMILY W/ 2009 SUPPLEMENTS
 FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH
  
 1. PREVIOUSLY UNCONDITIONED EXISTING BUILDINGS WHICH
 WERE PERMITTED PRIOR TO MARCH 15, 1979 TO WHICH HEATING
 OR COOLING SYSTEMS ARE ADDED SHALL MEET THE
 PRESCRIPTIVE REQUIREMENTS CONTAINED IN METHOD B OF
 SUBCHAPTER 13-4 FOR COMMERCIAL APPLICATIONS AND METHOD
 B OF SUBCHAPTER 13-6 FOR RESIDENTIAL APPLICATIONS OF
 THE CODE FOR INSULATION, HVAC SYSTEMS AND EXTERIOR
 ENVELOPE FOR THOSE COMPONENTS WHICH ARE BEING
 RETROFITTED OR REPLACED IN ACCORDANCE WITH FBC-B
 SECTION 13-101.4.1.1.
  
 2. PROVIDE COOLING LOAD CALCULATIONS ATTACHED TO THE
 METHOD B ENERGY CODE COMPLIANCE FORM IN ACCORDANCE WITH
 FBC-B SECTION 13-407.AB.1.
  
 3. PROVIDE ENSTALLATION DETAIL FOR INSTALLATION OF
 CONDENSING UNITS ON THE ROOF IN ACCORDANCE WITH FBC-M
 301.12 AND FBC-B 1509.7.
  
 4. APPLIANCES ON ROOFS OR ELEVATED STRUCTURES SHALL
 COMPLY WITH THE REQUIREMENTS OF FBC-M 304.10 FOR GUARDS
 AND FBC-M 306.5 FOR ACCESS.
  
 5. PROVIDE AN EQUIPMENT SCHEDULE ON THE PLANS IN
 ACCORDANCE WITH FBC-M 303.1
  
 6. A RECEPTACLE OUTLET SHALL BE PROVIDED AT OR NEAR THE
 ROOFTOP EQUIPMENT LOCATION IN ACCORDANCE WITH FBC-M
 306.5.2.
  
 7. SHOW MEANS AND LOCATION OF CONDENSATE DISPOSAL IN
 ACCORDANCE WITH FBC-M 307.2.1.
  
 8. SHOW TEMINATION LOCATION OF BATHROOM EXHAUST IN
 ACCORDANCE WITH FBC-M 401.4 AND FBC-M 501.2.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT:
 RONALD J. REGUEIRO
 561.805.6719
 [email protected]

Review Stop P PLUMBING
Rev No 2 Status P Date 2009-08-31 Cont ID  
Sent By kstevens Date 2009-08-31 Time 15:55 Rev Time 0.00
Received By kstevens Date 2009-08-31 Time 15:55 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2009-08-10 Cont ID  
Sent By kstevens Date 2009-08-10 Time 10:01 Rev Time 0.00
Received By kstevens Date 2009-08-10 Time 10:01 Sent To  
Notes
2009-08-10 10:08:25DENIED
 REFERENCE:
 FBC-2007 PLUMBING
 FBC-2007 CHAPTER 1
  
 1. A WATER ISOMETRIC RISER DIAGRAM IS REQUIRED SHOWING
 ALL PIPE SIZES, VALVES, AND (WHERE REQUIED BY SECTION
 604.9) WATER HAMMER ARRESTORS. SECTION
 106.3.5.1.3(3)(8)(10)(13).
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]
  

Review Stop Z ZONING
Rev No 1 Status N Date 2009-07-27 Cont ID  
Sent By eschneid Date 2009-07-27 Time 15:07 Rev Time 0.33
Received By eschneid Date 2009-07-27 Time 15:07 Sent To  
Notes
2009-07-27 15:11:22INTERIOR IMPROVEMENTS VALUED LESS THAN 50% OF
 STRUCTURE.
  
 2008 STRUCTURE VALUE - $491,669