Plan Review Details - Permit 09070219
Plan Review Stops For Permit 09070219
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2009-07-17 Cont ID  
Sent By rmcdouga Date 2009-07-17 Time 09:41 Rev Time 0.00
Received By rmcdouga Date 2009-07-17 Time 09:41 Sent To  
Notes
2009-07-17 09:41:25BUILDING PROVISO
  
 1) SUBMIT 2 COPIES OF PRODUCT APPROVALS FOR THE SLIDING
 GLASS DOORS.
  
 2) SUBMIT 2 SETS OF REVISED TRUSS LAYOUTS THAT MATCH
 THE STRUCTURAL PLANS AND TRUSS DRAWINGS FOR GIRDER
 TRUSSES D1G AND K1G AS DISCUSSED WITH THE ENGINEER OF
 RECORD FOR THE PROJECT ( STEVE WALSH).
  
 3) SUBMIT 2 COPIES OF A DETAIL OF THE WOOD FRAME
 PORTION OF THE COMMON WALLS SHOWING THAT THE R-VALUE
 USED FOR THE INSULATION LEVEL IS THE R-VALUE OF THE
 ADDED INSULATION ONLY, AS REQUIRED BY CHAPTER 13 OF THE
 FLORIDA BUILDING CODE.
  
 THE ABOVE ITEMS ARE TO BE SUBMITTED AND APPROVED PRIOR
 TO INSTALLATION.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2009-07-29 Cont ID  
Sent By rmcdouga Date 2009-07-29 Time 09:55 Rev Time 0.00
Received By rmcdouga Date 2009-07-29 Time 09:55 Sent To  
Notes
2009-07-29 09:57:49REVIEWED FOR CODE COMPLIANCE BY DOUG WISE

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2009-07-24 Cont ID  
Sent By efabian Date 2009-07-24 Time 15:11 Rev Time 0.00
Received By efabian Date 2009-07-24 Time 15:11 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2009-07-30 Cont ID  
Sent By mawillia Date 2009-07-30 Time 11:25 Rev Time 0.00
Received By mawillia Date 2009-07-30 Time 11:16 Sent To B1
Notes
2009-07-30 11:22:46*****PROVISO*****
  
  
 AS TO BE DISCUSSED WITH THE WEST PALM BEACH BUILDING
 OFFICIAL AND RELAYED TO THE PROJECT MANAGER/DEVELOPER,
 ANY REVISION(S) TO THIS PLAN SET AND/OR ANY OTHER
 FUTURE PLAN SUBMITTALS FOR THE OAKTON COMMONS PROJECT
 SHALL INCLUDE THE FOLLOWING CORRECTION(S) OR
 ADDENDUM(S) FOR FIRE PLAN REVIEW'S APPROVAL:
  
 1. ON SHEET LP-1, THE FIRE HYDRANT SHOWN AT THE
 SOUTHWEST CORNER OF THE BUILDING SHOULD HAVE THE
 4"/4.5"OUTLET (STEAMER CAP) FACING THE ROADWAY (FOXTAIL
 VIEW COURT).
  
 2. ONLY FOR BUILDINGS WHICH CONTAIN 3 OR MORE DWELLING
 UNITS UNDER A COMMON ROOF, NFPA 101 - LIFE SAFETY CODE
 - 2006 EDITION SHALL BE REFERENCED. ADD TO CODE SECTION
  
 3. SHOW THE LOCATION OF THE 2A:10BC RATED FIRE
 EXTINGUISHER(S) THAT SATISFY THE 75 ' TRAVEL DISTANCE.
 THIS MAY BE ACCOMPLISHED ONE OF TWO WAYS: 1) PROVIDE AN
 ENCLOSED/PROTECTED FIRE EXTINGUISHER ON THE EXTERIOR
 ELEVATION COMMON TO THE BUILDING OR BETTER YET 2) THE
 PLACEMENT OF FIRE EXTINGUISHER(S) INSIDE EACH
 INDIVIDUAL DWELLING UNIT.
  
 4. ON SHEET A-3.1, FRONT ELEVATION, DISPLAY/SHOW THE
 ACTUAL NUMERICAL ADDRESS NUMBER FOR EACH UNIT. AS PER
 WEST PALM BEACH CODE, THE NUMBERS SHALL BE NO LESS THAN
 3" IN HEIGHT AND NO LESS THAN 1" IN WIDTH/STROKE.
  
 5. ON SHEETS E1.0 THRU E-1.4, ADD THE FOLLOWING VERBAGE
 AS PER FLORIDA STATUTE 553:885: " AN OPERATIONAL CARBON
 MONOXIDE (CO) ALARM SHALL BE INSTALLED WITHIN 10 FEET
 OF EACH ROOM USED FOR SLEEPING PURPOSES." IT APPEARS
 THAT THE CO DETECTOR SHOWN ON THE SECOND FLOOR OF THE
 DWELLING UNITS CAN BE BETTER CENTERED/ALIGNED TO ATTAIN
 THE DISTANCE REQUIREMENT.
  
 PLAN SHEETS TU-1.0, TU-1.1, TU-2.0, TU-2.1, TU-3.0,
 A-3.1, E-1.0, E1.1, E1.2, E-1.3, AND E-1.4 WERE
 STAMPED, INITIALED, AND DATED.
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722
 FIRE PREVENTION BUREAU
 561-804-4724

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-07-29 Cont ID  
Sent By rmcdouga Date 2009-07-29 Time 10:00 Rev Time 0.00
Received By rmcdouga Date 2009-07-29 Time 10:00 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status P Date 2009-07-28 Cont ID  
Sent By rmcdouga Date 2009-07-28 Time 14:15 Rev Time 0.00
Received By rmcdouga Date   Time   Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2009-07-29 Cont ID  
Sent By rmcdouga Date 2009-07-29 Time 09:58 Rev Time 0.00
Received By rmcdouga Date 2009-07-29 Time 09:58 Sent To  
Notes
2009-07-29 09:58:56REVIEWED FOR CODE COMPLIANCE BY DOUG WISE.

Review Stop P PLUMBING
Rev No 1 Status P Date 2009-07-29 Cont ID  
Sent By rmcdouga Date 2009-07-29 Time 09:59 Rev Time 0.00
Received By rmcdouga Date 2009-07-29 Time 09:59 Sent To  
Notes
2009-07-29 09:59:28REVIEWED FOR CODE COMPLIANCE BY DOUG WISE.

Review Stop Z ZONING
Rev No 1 Status P Date 2009-07-24 Cont ID  
Sent By eschneid Date 2009-07-24 Time 14:28 Rev Time 0.25
Received By eschneid Date 2009-07-24 Time 14:28 Sent To  
Notes
2009-08-10 10:29:02LANDSCAPE PERMIT FOR BUILDING 9 AND SITE SUBMITTED ON
 AUG. 5, 2009.
  
  
2009-07-24 14:29:03PASSED W/PROVISO
  
 1) BUILDING 9 REQUIRES A SEPARATE LANDSCAPE AND
 IRRIGATION PERMITS BE SUBMITTED BY AUGUST 7, 2009. IF
 PERMITS ARE NOT SUBMITTED, THEN ZONING WILL ISSUE A
 HOLD ON FURTHER INSPECTIONS UNTIL SUCH TIME AS THE
 PERMITS ARE SUBMITTED.
  
 2) THE LANDSCAPE AND IRRIGATION REQUIRED BY 1 ABOVE
 SHALL BE INSTALLED AND HAVE FINAL INSPECTION APPROVAL
 PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY
 (C.O.) FOR THIS PERMIT.
  
 3) PLEASE NOTE THAT THE SITE WORK PERMIT, INCLUDING
 LANDSCAPE AND IRRIGATION, FOR THE ROADWAYS AND COMMON
 AREAS WITHIN OAKTON PRESERVE SHALL BE SUBMITTED TO THE
 CONSTRUCTION SERVICES DEPARTMENT BY AUGUST 7, 2009. IF
 PERMITS ARE NOT SUBMITTED, THEN ZONING WILL ISSUE A
 HOLD ON FURTHER INSPECTIONS UNTIL SUCH TIME AS THE
 PERMITS ARE SUBMITTED.
  
 4) THE SITE WORK, INCLUDING LANDSCAPE AND IRRIGATION,
 FOR THE ROADWAYS AND COMMONS AREAS REQUIRED BY 2 ABOVE
 SHALL BE INSTALLED AND HAVE FINAL INSPECTION APPROVAL
 PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY
 (C.O.) FOR THIS PERMIT.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1435.
  