Plan Review Stops For Permit 09060651 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
P |
Date |
2009-09-28 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2009-09-28 |
Time |
13:46 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2009-09-28 |
Time |
13:46 |
Sent To |
|
|
Notes |
2009-09-28 13:46:18 | PASSED W/REDLINES | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
F |
Date |
2009-09-14 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2009-09-14 |
Time |
14:28 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2009-09-14 |
Time |
14:28 |
Sent To |
|
|
Notes |
2009-09-14 14:33:57 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBC FLORIDA BUILDING CODE 2007 WITH 2009 SUPPLEMENTS | | FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING | | CODE | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | FAC FLORIDA ADMINISTRATIVE CODE | | FS FLORIDA STATUTE | | | | 1. SHUTTER MOUNTING CONNECTION TYPE "A" REQUIRES A | | CONCRETE SUBSTRATE; CONCRETE BLOCK SPECIFIED ON THE | | INSTALLATION SCHEDULE (AND "MASONRY" CHECKED AT TOP OF | | FORM). PLEASE SEE SHEET 13 OF THE PRODUCT APPROVAL. | | | | 2. SHUTTER MOUNTING CONNECTION TYPE "I" REQUIRES A | | CONCRETE SUBSTRATE; CONCRETE BLOCK SPECIFIED ON THE | | INSTALLATION SCHEDULE. PLEASE SEE SHEET 15 OF THE | | PRODUCT APPROVAL. ALSO NOTE THAT CONCRETE IS REQUIRED | | TO BE 3KSI (SEE SHEET 14, NOTE 1); RESIDENTIAL SLABS | | ARE USUALLY 2500PSI. PLEASE FEEL FREE TO CONTACT ME IF | | YOU NEED ASSISTANCE WITH THIS ITEM. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2009-08-05 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2009-08-05 |
Time |
15:57 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2009-08-05 |
Time |
15:57 |
Sent To |
|
|
Notes |
2009-08-05 16:03:18 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBC FLORIDA BUILDING CODE 2007 | | FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING | | CODE | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2007 | | FAC FLORIDA ADMINISTRATIVE CODE | | FS FLORIDA STATUTE | | | | | | 1. THE LETTER WAS SUBMITTED WITH WHAT APPEARS TO BE AN | | OLD CODE (PRIOR TO FBC2004 WITH 2007 SUPPLEMENTS). | | ASCE7 HAS NOT HAD AN EXPOSURE A FOR SEVERAL CODE | | CYCLES. PLEASE SEE FBC2007, 2009 SUPPLEMENTS TO THE | | FLORIDA BUILDING CODE. THE DEFINITION OF EXPOSURE C IN | | THE FLORIDA BUILDING CODE HAS BEEN REVISED EVERY YEAR | | FOR SEVERAL YEARS IN A ROW. THEREFORE, IT WOULD BE BEST | | NOT TO RELY ON OUTDATED CODES. THE CODE IS AVAILABLE AT | | WWW.FLORIDABUILDING.ORG, BUT PLEASE NOTE THE | | SUPPLEMENTS/REVISIONS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2009-07-16 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2009-07-16 |
Time |
19:09 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2009-07-16 |
Time |
19:09 |
Sent To |
|
|
Notes |
2009-07-16 19:10:11 | ***PROVISO*** | | THIS PERMIT IS ISSUED WITH PROVISO | | REVISION REQUIRED - INSPECTION HOLD HAS BEEN PLACED ON | | THIS | | PERMIT SUBJECT TO REQUIRED REVISION | | | | COMPLETE THE ATTACHED INSTALLATION SCHEDULE OR PROVIDE | | ALL INFORMATION TO SHOW CODE | | COMPLIANCE IN ANOTHER FORMAT, FBC*106, FBC R301, | | FBC1609. TWO SETS REQUIRED. | | THIS FORM IS AVAILABLE IN THE LOBBY OR ON THE INTERNET | | AT | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_ | | INSTALLATION.PDF | | | | EXPOSURE C DESIGN PRESSURES REQUIRED | | | | REVISION REQUIRED PRIOR TO FIRST INSPECTION | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2009-07-06 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2009-07-06 |
Time |
17:19 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2009-07-06 |
Time |
17:19 |
Sent To |
|
|
Notes |
2009-07-06 17:27:02 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBC FLORIDA BUILDING CODE 2007 WITH 2009 SUPPLEMENTS | | FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING | | CODE | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | FAC FLORIDA ADMINISTRATIVE CODE | | FS FLORIDA STATUTE | | | | 1. PLEASE PROVIDE EVIDENCE THAT THIS JOB IS LOCATED IN | | EXPOSURE B. BASED ON AERIALS, IT APPEARS THAT THIS JOB | | IS LOCATED IN EXPOSURE C, FBC R301. | | | | 2. PLEASE CLARIFY SHUTTER SPAN. THIS IS TYPICALLY THE | | BLADE LENGTH. PLEASE EITHER REVISE TO CORRESPOND WITH | | THE HEIGHT OR EXPLAIN WHY THE SPAN CORRELATES WITH THE | | WIDTH. | | | | 3. SHUTTER MOUNTING CONNECTION TYPE, THIS SHOULD | | CORRELATE WITH THE ANCHOR CHARTS. FOR THIS PRODUCT | | APPROVAL, THIS WILL BE A LETTER; FOR INSTANCE, A W/12 | | (SEE TOP OF FIRST COLUMN, PAGE 13 AND CORRESPONDING | | DETAIL ON SHEET 6. PLEASE NOTE THAT NOT ALL OF THE | | MOUNTING TYPES ARE PERMITTED WITH A CONCRETE BLOCK | | SUBSTRATE. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2009-06-24 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2009-06-24 |
Time |
15:41 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2009-06-24 |
Time |
15:41 |
Sent To |
|
|
Notes |
2009-06-24 15:41:39 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2007 | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | 1. COMPLETE THE SAMPLE INSTALLATION SCHEDULE OR PROVIDE | | ALL INFORMATION TO SHOW CODE COMPLIANCE IN ANOTHER | | FORMAT, FBC*106, FBC R301, FBC1609. TWO SETS REQUIRED. | | THIS FORM IS AVAILABLE IN THE LOBBY OR ON THE INTERNET | | AT | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_ | | INSTALLATION.PDF | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2009-09-24 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2009-09-24 |
Time |
08:34 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2009-09-24 |
Time |
08:34 |
Sent To |
|
|
Notes |
2009-09-24 08:34:50 | GAVE TO SAMANTHA |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2009-07-09 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2009-07-09 |
Time |
13:48 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2009-07-09 |
Time |
13:48 |
Sent To |
|
|
Notes |
2009-07-09 13:48:28 | SENT TO SAMANTA'S DESK. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2009-07-01 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-07-01 |
Time |
08:14 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-07-01 |
Time |
08:14 |
Sent To |
|
|
Notes |
2009-07-01 08:15:34 | SENT TO S HILL'S DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2009-06-24 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2009-06-24 |
Time |
15:41 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2009-06-24 |
Time |
08:35 |
Sent To |
|
|
Notes |
|
|