Plan Review Details - Permit 09060526
Plan Review Stops For Permit 09060526
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2009-07-27 Cont ID  
Sent By jwitmer Date 2009-07-27 Time 11:30 Rev Time 0.00
Received By jwitmer Date 2009-07-27 Time 11:00 Sent To  
Notes
2009-07-27 12:03:04BUILDING PROVISO:
 STUCCO OVER WOOD FRAME CONSTRUCTION REQUIRES A BOND
 BRAKER. 1404.2.1 WHERE CEMENT PLASTER (STUCCO) IS TO BE
 APPLIED TO LATH OVER FRAME CONSTRUCTION, MEASURES SHALL
 BE TAKEN TO PREVENT BONDING BETWEEN THE CEMENT PLASTER
 AND THE WATER RESISTIVE BARRIER. A BOND BREAK SHALL BE
 PROVIDED BETWEEN THE WATER RESISTIVE BARRIER AND THE
 CEMENT PLASTER (STUCCO) CONSISTING OF ONE OF THE
 FOLLOWING:
  
 1. TWO LAYERS OF AN APPROVED WATER-RESISTANT BARRIER OR
  
 2. ONE LAYER OF AN APPROVED WATER-RESISTANT BARRIER
 OVER AN APPROVED PLASTIC HOUSE WRAP, OR
  
 3. OTHER APPROVED METHODS OR MATERIALS APPLIED IN
 ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION
 INSTRUCTIONS.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2009-07-06 Cont ID  
Sent By jwitmer Date 2009-07-06 Time 11:36 Rev Time 3.30
Received By jwitmer Date 2009-07-01 Time 14:20 Sent To  
Notes
2009-07-06 13:05:13BUILDING PLAN REVIEW
 PERMIT:09060526
 ADD: 3512 S DIXIE HWY
 CONT: KARNS CONSTRUCTION
 TEL: (561)767-6118
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW
 ACTION: DENIED
  
 1) INFORMATIONAL 106.1.1* W.P.B. ADMINISTRATIVE
 CODE/2007 -OPTIONS- DRAWINGS & SPECIFICATIONS SHALL
 CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE,
 AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS
 ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH
 INFORMATION SHALL BE SPECIFIC TO THE TECHNICAL CODES
 "SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR THE TERM
 "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE FOR
 SPECIFIC INFORMATION". CONSTRUCTION DOCUMENTS SHALL BE
 SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND
 EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT
 WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL.
  
 NOTE NOA 08-0512.10 IS A TAMKO MODIFIED SYSTEM OVER
 CONCRETE DECKS PRESSURE -622.5 FOR NON-INSULATED
 CONCRETE DECK, IF GIVEN THE OPTION FOR 1 1/2 INCHES OF
 ROOF INSULATION THE WRONG REPORT WOULD HAVE BEEN
 SUBMITTED.
  
 2) MISSING THTTE WIND DESIGN INFORMATION: 1603.1.4 WIND
 DESIGN DATA.
 THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL
 BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE
 DESIGN OF THE LATERAL-FORCE-RESISTING SYSTEM OF THE
 BUILDING:
 2A) BASIC WIND SPEED (3-SECOND GUST), MILES PER HOUR
 (KM/HR).
  
 2B) WIND IMPORTANCE FACTOR, I W , AND BUILDING
 CLASSIFICATION FROM TABLE 1604.5 OR TABLE 6-1, ASCE 7
 AND BUILDING CLASSIFICATION IN TABLE 1-1, ASCE 7.
  
 2C) WIND EXPOSURE, IF MORE THAN ONE WIND EXPOSURE IS
 UTILIZED, THE WIND EXPOSURE AND APPLICABLE WIND
 DIRECTION SHALL BE INDICATED.
  
 2D) THE APPLICABLE ENCLOSURE CLASSIFICATIONS AND, IF
 DESIGNING WITH ASCE 7, INTERNAL PRESSURE COEFFICIENT.
  
 2E) COMPONENTS AND CLADDING. THE DESIGN WIND PRESSURES
 IN TERMS OF PSF (KN/M 2 ) TO BE USED FOR THE SELECTION
 OF EXTERIOR COMPONENTS AND CLADDING MATERIALS NOT
 SPECIFICALLY
 DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL.
  
 3) THE REAR SLOPED ROOFING PRODUCT APPROVAL SUBMITTED
 INDICATES IN THE NOA08-0226.06 A SURFACING PRODUCT FOR
 A FINISHED PRODUCT PLEASE SEE TABLE 4 CIRCLE THE
 PRODUCT TO BE INSTALLED.
  
 4) STUCCO OVER WOOD FRAME CONSTRUCTION REQUIRES A BOND
 BRAKER. 1404.2.1 WHERE CEMENT PLASTER (STUCCO) IS TO BE
 APPLIED TO LATH OVER FRAME CONSTRUCTION, MEASURES SHALL
 BE TAKEN TO PREVENT BONDING BETWEEN THE CEMENT PLASTER
 AND THE WATER RESISTIVE BARRIER. A BOND BREAK SHALL BE
 PROVIDED BETWEEN THE WATER RESISTIVE BARRIER AND THE
 CEMENT PLASTER (STUCCO) CONSISTING OF ONE OF THE
 FOLLOWING:
  
 1. TWO LAYERS OF AN APPROVED WATER-RESISTANT BARRIER OR
  
 2. ONE LAYER OF AN APPROVED WATER-RESISTANT BARRIER
 OVER AN APPROVED PLASTIC HOUSE WRAP, OR
  
 3. OTHER APPROVED METHODS OR MATERIALS APPLIED IN
 ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION
 INSTRUCTIONS.
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
 SURVEY:
 WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2009-07-30 Cont ID  
Sent By dpalmer Date 2009-07-30 Time 15:56 Rev Time 0.00
Received By dpalmer Date 2009-07-30 Time 15:55 Sent To  
Notes
2009-07-30 15:56:15ELEC SUB PERMIT REQUIRED.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2009-07-04 Cont ID  
Sent By dpalmer Date 2009-07-04 Time 12:21 Rev Time 0.00
Received By dpalmer Date 2009-07-04 Time 12:21 Sent To  
Notes
2009-07-04 12:22:06 
 ** DENIED PLANS REVIEW **
  
 1) NOTE: AN ELECTRICAL PERMIT IS BEING APPLIED FOR YET
 NO ELECTRICAL FOR SCOPE OF WORK IS SHOWN.
 PLEASE SUBMIT ANY ELECTRICAL SCOPE IN COMPLIANCE WITH
 APPLICABLE CODES.
 2007 FBC W/2009 SUPPLEMENTS
 2005 NFPA-70
 2006 NFPA-101
  
 IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT
 TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO
 CONTACT THIS REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2009-08-03 Cont ID  
Sent By mawillia Date 2009-08-03 Time 10:36 Rev Time 0.00
Received By mawillia Date 2009-08-03 Time 10:21 Sent To B
Notes
2009-08-03 10:31:02*****APPROVED*****
  
 PLAN SHEET 1 (OF 2) WAS STAMPOED, INITIALED, AND DATED.
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2009-07-09 Cont ID  
Sent By mawillia Date 2009-07-09 Time 09:56 Rev Time 0.00
Received By mawillia Date 2009-07-09 Time 09:47 Sent To  
Notes
2009-07-09 09:55:29*****PROVISO*****
  
  
 THE APPROPIATE PLAN SHEET(S) TO BE FIRE STAMPED WHEN
 THE OTHER EXAMINERS' AS WELL AS THE FOLLOWING COMMENTS
 HAVE BEEN ADDRESSED:
  
 1. STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR
 DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241 - 2004
 EDITION.
  
 2. DISPLAY/SHOW THE THE NUMERICAL ADDRESS ON THE
 EXTERIOR ELEVATION WHICH FRONTS SOUTH DIXIE HIGHWAY. AS
 PER WEST PALM BEACH CODE, THOSE NUMBERS SHALL BE NO
 LESS THAN 6" IN HEIGHT AND NO LESS THAN 1" IN
 WIDTH/STROKE.
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2009-07-15 Cont ID  
Sent By shill Date 2009-07-15 Time 14:01 Rev Time 0.00
Received By shill Date 2009-07-15 Time 14:01 Sent To  
Notes
2009-07-15 14:02:41B8
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-07-15 Cont ID  
Sent By shill Date 2009-07-09 Time 14:01 Rev Time 0.00
Received By shill Date 2009-06-24 Time 09:57 Sent To  
Notes
2009-06-24 09:56:29SENT TO BOB #24

Review Stop Z ZONING
Rev No 2 Status P Date 2009-07-23 Cont ID  
Sent By astelly Date 2009-07-23 Time 16:19 Rev Time 0.00
Received By astelly Date 2009-07-23 Time 16:19 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date   Cont ID  
Sent By   Date 2009-07-07 Time   Rev Time 0.00
Received By astelly Date 2009-07-07 Time 10:15 Sent To  
Notes
2009-07-07 10:16:49AMY STELLY
 PLANNING & ZONING
 822-1442
  
 APPLICANT MUST SUBMIT A SITE PLAN SHOWING PROPOSED
 LOCATION OF PLANTING IN PEDESTRIAN WALKWAY.
 SITE PLAN MUST SHOW THE LOCATION OF ALL SPACES, AND THE
 HANDICAP PARKING STALL MUST BE CLEARLY IDENTIFIED.