Plan Review Details - Permit 09060411
Plan Review Stops For Permit 09060411
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2009-06-18 Cont ID  
Sent By jgomez Date 2009-06-18 Time 14:39 Rev Time 0.00
Received By jgomez Date 2009-06-18 Time 08:43 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status   Date 2009-06-17 Cont ID  
Sent By jgomez Date 2009-06-17 Time 15:48 Rev Time 0.00
Received By jgomez Date 2009-06-17 Time 15:48 Sent To  
Notes
2009-06-17 15:49:43TALKED TO RAY NEED UNDERLAYMENT PRODUCT APPROVAL THAT
 SUPERSEDES NOA SUBMITTED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2009-06-16 Cont ID  
Sent By jgomez Date 2009-06-16 Time 15:29 Rev Time 0.00
Received By jgomez Date 2009-06-16 Time 15:29 Sent To PC
Notes
2009-06-16 16:25:45RESIDENTIAL (R3) RE-ROOF, BUILDING REVIEW CHECKLIST.
 2007 FL. RESIDENTIAL CODE WITH 2009 REVISIONS.
  
 1- ACCORDING TO APPROVED ASSEMBLIES ON SHEET 3 OF
 UNDERLAYMENT NOA 07-1130.01 SUBMITTED THIS UNDERLAYMENT
 CAN ONLY BE USED WHEN THE APPROVED ROOFING ASSEMBLY
 ALLOWS AN ASTM D 1970 UNDERLAYMENT. ROOFING ASSEMBLY
 SUBMITTED DOESN'T ALLOW THIS TYPE OF UNDERLAYMENT.
 PROVIDE UNDERLAYMENT PRODUCT APPROVAL THAT IS ALLOWED
 BY THE ROOFING ASSEMBLY SUBMITTED.
  
 2- LIMITATION #6 ON SHEET 4 OF UNDERLAYMENT NOA
 07-1130.01 SUBMITTED STATES THAT MAXIMUM ROOF PITCH IS
 4:12. PERMIT APPLICATION STATES 9:12 PITCH. THIS
 UNDERLAYMENT DOESN'T WORK FOR PROPOSED INSTALLATION.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-06-17 Cont ID  
Sent By jgomez Date 2009-06-17 Time 09:02 Rev Time 0.00
Received By jgomez Date 2009-06-16 Time 15:29 Sent To  
Notes
***NONE***