Plan Review Details - Permit 09060394
Plan Review Stops For Permit 09060394
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2009-08-31 Cont ID  
Sent By shill Date 2009-08-31 Time 15:46 Rev Time 0.00
Received By shill Date 2009-08-31 Time 15:46 Sent To  
Notes
2009-08-31 15:46:31REVISION SHEET A1 DATED 8/19/9

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2009-07-29 Cont ID  
Sent By shill Date 2009-07-29 Time 11:46 Rev Time 0.00
Received By shill Date 2009-07-29 Time 08:08 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2009-06-18 Cont ID  
Sent By shill Date 2009-06-18 Time 16:31 Rev Time 0.00
Received By shill Date 2009-06-18 Time 16:31 Sent To  
Notes
2009-06-18 16:40:03****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2007
 FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2007
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
 1. DECLARE WIND DESIGN CRITERIA, INCLUDING COMPONENT &
 CLADDING PRESSURES, FBC1603.1.4.
  
 2. PLEASE CLARIFY; GUARDRAILS FOR BALCONIES ARE TO
 REMAIN IN PLACE OR SHOW HOW THIS IMPROVEMENT WILL
 COMPLY WITH FBC1013.1.
  
 3. A1 SHOWS THIS IMPROVEMENT ON THE 24TH FLOOR (BUT
 APPEARS TO HAVE BEEN CHANGED BY HAND), D1 SHOWS 14TH
 FLOOR. PLEASE CORRELATE.
  
 4. IF ALL OPTIONS ON THE PRODUCT APPROVAL DO NOT COMPLY
 WITH DESIGN PRESSURES SPECIFIED (COMMENT 1), PLEASE
 INDICATE WHICH OPTION YOU ARE USING. FBC1609.
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2009-07-30 Cont ID  
Sent By dpalmer Date 2009-07-30 Time 15:29 Rev Time 0.00
Received By dpalmer Date 2009-07-30 Time 15:29 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2009-07-04 Cont ID  
Sent By dpalmer Date 2009-07-04 Time 10:42 Rev Time 0.00
Received By dpalmer Date 2009-07-04 Time 10:42 Sent To  
Notes
2009-07-04 10:42:36 
 ** DENIED PLANS**
  
 1) NOTE: PLANS NEED TO STATE THE FOLLOWING CODES AT A
 MINIMUM.
 2005 NFPA_70
 2006 NFPA-101
 2002 NFPA-72
  
 2) NOTE: ELECTRICAL IS OK IN GENERAL HOWEVER BASED ON
 THE FACT THE ELECTRICAL IS SHOWN ON THE A-1 SHEET WHICH
 NEEDS TO BE REVISED FOR OTHER TRADES, THE SHEETS WILL
 NOT BE STAMPED AT THIS TIME.
  
 IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT
 TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO
 CONTACT THIS REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2009-07-30 Cont ID  
Sent By mawillia Date 2009-07-30 Time 12:49 Rev Time 0.00
Received By mawillia Date 2009-07-30 Time 12:38 Sent To  
Notes
2009-07-30 12:49:17*****APPROVED*****
  
 PLAN SHEET A1 WAS STAMPED, INITIALED, AND DATED
 PREVIOUSLY FIRE-STAMPED ON 6/30/2009.
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2009-06-30 Cont ID  
Sent By mawillia Date 2009-06-30 Time 14:43 Rev Time 0.00
Received By mawillia Date 2009-06-30 Time 14:12 Sent To  
Notes
2009-06-30 14:43:20*****APPROVED*****
  
  
 PLAN SHEET A1 WAS STAMPED, INITIALED, AND DATED.
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2009-08-25 Cont ID  
Sent By lmartine Date 2009-08-25 Time 15:34 Rev Time 0.00
Received By lmartine Date 2009-08-25 Time 15:34 Sent To  
Notes
2009-08-25 15:35:16GAVE TO SAMANTHA

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2009-07-15 Cont ID  
Sent By shill Date 2009-07-15 Time 14:09 Rev Time 0.00
Received By shill Date 2009-07-15 Time   Sent To  
Notes
2009-07-15 14:09:45B12
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2009-07-13 Time   Rev Time 0.00
Received By lmartine Date 2009-06-15 Time 15:49 Sent To R
Notes
2009-06-16 15:50:08GAVE TO SAMANTHA

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status P Date 2009-07-30 Cont ID  
Sent By dpalmer Date 2009-07-30 Time 15:29 Rev Time  
Received By dpalmer Date   Time   Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2009-07-29 Cont ID  
Sent By rregueir Date 2009-07-29 Time 13:31 Rev Time 0.00
Received By rregueir Date 2009-07-29 Time 13:31 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2009-07-13 Cont ID  
Sent By rregueir Date 2009-07-13 Time 14:14 Rev Time 0.00
Received By rregueir Date 2009-07-13 Time 14:14 Sent To R
Notes
2009-07-13 14:14:46NO MECHANICAL PERMIT REQUIRED

Review Stop Z ZONING
Rev No 1 Status P Date 2009-06-25 Cont ID  
Sent By aaponte Date 2009-06-25 Time 10:50 Rev Time 0.00
Received By aaponte Date 2009-06-25 Time 10:50 Sent To  
Notes
***NONE***