Plan Review Details - Permit 09060147
Plan Review Stops For Permit 09060147
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2009-07-22 Cont ID  
Sent By shill Date 2009-07-22 Time 18:20 Rev Time 0.00
Received By shill Date 2009-07-22 Time 18:20 Sent To  
Notes
2009-07-22 18:20:43PASSED W/REDLINE, 45 MIN DOORS IN TENANT SEPARATION
 WALL

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2009-06-15 Cont ID  
Sent By shill Date 2009-06-15 Time 20:37 Rev Time 0.00
Received By shill Date 2009-06-15 Time 20:37 Sent To  
Notes
2009-06-15 20:38:03PASSED W/REDLINE, 45 MIN DOORS IN TENANT SEPARATION
 WALL

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2009-10-28 Cont ID  
Sent By dpalmer Date 2009-10-28 Time 08:38 Rev Time 0.00
Received By dpalmer Date 2009-10-28 Time 08:38 Sent To  
Notes
2009-10-28 08:38:30** DENIED **
  
 SPEC SPACE #6 ON FLOOR 6.
  
 1) NOTE: SHEET E-1 DOES NOT ACTUALLY INDICATE ANY
 REVISION IN THE TITLE BLOCK OR ON THE PLANS.
 SHEET E-2 DOES CONTAIN A REVISION #3 IN THE TITLE BLOCK
 HOWEVER NO REVISION ON PLANS.
 SHEET E-3 DOES CONTAIN A REVISION #3 ON THE TITLE
 BLOCKS HOWEVER NO REVISION ON PLANS.
  
 IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT
 TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO
 CONTACT THIS REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2009-07-21 Cont ID  
Sent By dpalmer Date 2009-07-21 Time 19:10 Rev Time 0.00
Received By dpalmer Date 2009-07-21 Time 19:10 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2009-06-18 Cont ID  
Sent By dpalmer Date 2009-06-18 Time 10:25 Rev Time 0.00
Received By dpalmer Date 2009-06-18 Time 10:25 Sent To  
Notes
2009-06-18 10:25:13 
 ** DENIED PLANS *
  
 1) NOTE: THE ELECTRICAL PLANS NEED TO STATE THE
 FOLLOWING MINIMUM CODES.
 PLEASE BE SURE THE FOLLOWING ARE STATED ON ELECTRICAL
 PLANS.
 2007 FBC W/ 2009 AMENDMENTS.
 2006 NFPA-101 ( PLANS STATE 2007 FOR THIS CODE)
 2002 NFPA-72 (OK)
 2006 NFPA-1
 2005 NFPA-70 ( PLANS STATE 2007) PLEASE BE ADVISED EVEN
 ONCE THE CODE CHANGE GOES INTO AFFECT THE IT WILL BE
 THE 2008 NEC.
  
 PER: FBC CHAPTER 35, FS 553.73, FAC 69A-60.004, .003
  
 2) NOTE: PLEASE SEE 13-415.AB.5 AND 13-415.AB.5.1 FOR
 LIGHTING PERFORMANCE CALCULATIONS. THE SECTION WHICH
 USED TO ALLOW TRADE OFFS FOR OTHER AREAS IS NO LONGER
 IN THE CODE. THE ALLOWANCE FOR SCONCES, CHANDELIERS ETC
 ARE ALSO NOT IN THE CODE.
 PLANS SHOW CALCULATIONS FOR MOST AREAS HOWEVER SOME ARE
 IN QUESTION.
 FOR EXAMPLE: ROOM 643 EXCEEDS ALLOWANCE FOR CLOSET.
  
 3) NOTE: PLEASE INCLUDE ALL DEVICE LOCATIONS, HEIGHTS,
 AND MINIMUM LEVELS PER FBC 11-4.28.1,.2 AND .3.
 THERE ARE SOME DEVICES ON PLANS HOWEVER NO DETAILS OR
 INFORMATION ON SYMBOL LEGEND.
  
 4) NOTE: PLEASE CLARIFY WHY PANEL 6-OHP IS SHOWN.
 FBC 106.1.1, 106.1.2 FOR ADDITIONAL INFORMATION.
 NEC 408,240,
  
  
  
  
  
  
 ** IMPORTANT **
 ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP
 FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE
 ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING.
 DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS.
 PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY
 ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS,
 SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED
 INTO TWO SETS/FOLDERS/BINDERS ETC.
 PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS
 SHOULD BE SUBMITTED FOR REFERENCE.
 THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID
 ANY DELAYS.
  
  
 IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT
 TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO
 CONTACT THIS REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2009-07-22 Cont ID  
Sent By mawillia Date 2009-07-22 Time 16:11 Rev Time 0.00
Received By mawillia Date 2009-07-22 Time 16:02 Sent To B
Notes
2009-07-22 16:10:39*****APPROVED*****
  
 THE PROVISO COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEW
 HAVE BEEN ADDRESSED; PLAN SHEETS A1.1, A2.1, A3.1, AND
 E2 WERE STAMPED, INITIALED, AND DATED.
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2009-06-22 Cont ID  
Sent By mawillia Date 2009-06-22 Time 14:34 Rev Time 0.00
Received By mawillia Date 2009-06-22 Time 14:26 Sent To  
Notes
2009-06-22 14:28:39*****PROVISO*****
  
 1. STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR
 DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241 - 2004
 EDITION.
  
 2. ON SHEET A3.1, GENERAL NOTE #8 AND #9 REFERENCES
 FLORIDA FIRE PREVENTION CODE - 2004 EDITION. CORRELATE
 TO CURRENT EDITION AS CORRECTLY SHOWN ON SHEET T UNDER
 CODES.
  
 3. ON SHEET A3.1, AS PER BUILDING EXAMINER'S
 RED-LINING, THE NEW FIRE RATED DOOR (DOOR A) SHALL BE
 45 MINUTES.
  
 4. WILL THE SCOPE OF WORK HAVE CAUSE FOR THE SPRINKLER
 HEADS TO BE REMODELED IN ANY MANNER? IF SO, PROVIDE A
 LAYOUT OF THE FIRE SPRINKLER. (THEY MAY BE SHOWN ON
 SHEET A2.1, REFLECTED CEILING PLAN).
  
  
 THE APPROPIATE PLAN SHEET(S) TO BE FIRE-STAMPED WHEN
 THE ABOVE AS WELL AS OTHER PLAN EXAMINER(S)' COMMENTS
 HAVE BEEN ADDRESSED
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop I INCOMING/PROCESSING
Rev No 3 Status   Date 2009-10-20 Cont ID  
Sent By btrobaug Date 2009-10-20 Time 13:24 Rev Time 0.00
Received By btrobaug Date 2009-10-20 Time 13:24 Sent To  
Notes
2009-10-20 13:24:18B9

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2009-07-15 Cont ID  
Sent By shill Date 2009-07-15 Time 14:53 Rev Time 0.00
Received By shill Date 2009-07-15 Time 14:53 Sent To  
Notes
2009-07-15 14:54:06B14
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2009-07-06 Time   Rev Time 0.00
Received By rmcdouga Date 2009-06-08 Time 14:23 Sent To PC
Notes
2009-06-08 14:24:29TO B11

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2009-11-06 Cont ID  
Sent By rregueir Date 2009-11-06 Time 09:56 Rev Time 0.00
Received By rregueir Date 2009-11-06 Time 09:56 Sent To  
Notes
2009-11-06 09:56:43REVISED M1 DELTA 4, M2 DELTA 1

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2009-07-06 Cont ID  
Sent By rregueir Date 2009-07-06 Time 15:59 Rev Time 0.00
Received By rregueir Date 2009-07-06 Time 15:59 Sent To PC
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2009-06-17 Cont ID  
Sent By kstevens Date 2009-06-17 Time 16:02 Rev Time 0.00
Received By kstevens Date 2009-06-17 Time 16:01 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status N Date 2009-06-23 Cont ID  
Sent By aaponte Date 2009-06-23 Time 10:55 Rev Time 0.00
Received By aaponte Date 2009-06-23 Time 10:55 Sent To  
Notes
***NONE***