Plan Review Stops For Permit 09060147 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2009-07-22 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2009-07-22 |
Time |
18:20 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2009-07-22 |
Time |
18:20 |
Sent To |
|
|
Notes |
2009-07-22 18:20:43 | PASSED W/REDLINE, 45 MIN DOORS IN TENANT SEPARATION | | WALL |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2009-06-15 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2009-06-15 |
Time |
20:37 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2009-06-15 |
Time |
20:37 |
Sent To |
|
|
Notes |
2009-06-15 20:38:03 | PASSED W/REDLINE, 45 MIN DOORS IN TENANT SEPARATION | | WALL |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2009-10-28 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-10-28 |
Time |
08:38 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-10-28 |
Time |
08:38 |
Sent To |
|
|
Notes |
2009-10-28 08:38:30 | ** DENIED ** | | | | SPEC SPACE #6 ON FLOOR 6. | | | | 1) NOTE: SHEET E-1 DOES NOT ACTUALLY INDICATE ANY | | REVISION IN THE TITLE BLOCK OR ON THE PLANS. | | SHEET E-2 DOES CONTAIN A REVISION #3 IN THE TITLE BLOCK | | HOWEVER NO REVISION ON PLANS. | | SHEET E-3 DOES CONTAIN A REVISION #3 ON THE TITLE | | BLOCKS HOWEVER NO REVISION ON PLANS. | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | CONTACT THIS REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2009-07-21 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-07-21 |
Time |
19:10 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-07-21 |
Time |
19:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2009-06-18 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-06-18 |
Time |
10:25 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-06-18 |
Time |
10:25 |
Sent To |
|
|
Notes |
2009-06-18 10:25:13 | | | ** DENIED PLANS * | | | | 1) NOTE: THE ELECTRICAL PLANS NEED TO STATE THE | | FOLLOWING MINIMUM CODES. | | PLEASE BE SURE THE FOLLOWING ARE STATED ON ELECTRICAL | | PLANS. | | 2007 FBC W/ 2009 AMENDMENTS. | | 2006 NFPA-101 ( PLANS STATE 2007 FOR THIS CODE) | | 2002 NFPA-72 (OK) | | 2006 NFPA-1 | | 2005 NFPA-70 ( PLANS STATE 2007) PLEASE BE ADVISED EVEN | | ONCE THE CODE CHANGE GOES INTO AFFECT THE IT WILL BE | | THE 2008 NEC. | | | | PER: FBC CHAPTER 35, FS 553.73, FAC 69A-60.004, .003 | | | | 2) NOTE: PLEASE SEE 13-415.AB.5 AND 13-415.AB.5.1 FOR | | LIGHTING PERFORMANCE CALCULATIONS. THE SECTION WHICH | | USED TO ALLOW TRADE OFFS FOR OTHER AREAS IS NO LONGER | | IN THE CODE. THE ALLOWANCE FOR SCONCES, CHANDELIERS ETC | | ARE ALSO NOT IN THE CODE. | | PLANS SHOW CALCULATIONS FOR MOST AREAS HOWEVER SOME ARE | | IN QUESTION. | | FOR EXAMPLE: ROOM 643 EXCEEDS ALLOWANCE FOR CLOSET. | | | | 3) NOTE: PLEASE INCLUDE ALL DEVICE LOCATIONS, HEIGHTS, | | AND MINIMUM LEVELS PER FBC 11-4.28.1,.2 AND .3. | | THERE ARE SOME DEVICES ON PLANS HOWEVER NO DETAILS OR | | INFORMATION ON SYMBOL LEGEND. | | | | 4) NOTE: PLEASE CLARIFY WHY PANEL 6-OHP IS SHOWN. | | FBC 106.1.1, 106.1.2 FOR ADDITIONAL INFORMATION. | | NEC 408,240, | | | | | | | | | | | | | | ** IMPORTANT ** | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED | | INTO TWO SETS/FOLDERS/BINDERS ETC. | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | SHOULD BE SUBMITTED FOR REFERENCE. | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | ANY DELAYS. | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | CONTACT THIS REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2009-07-22 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2009-07-22 |
Time |
16:11 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2009-07-22 |
Time |
16:02 |
Sent To |
B |
|
Notes |
2009-07-22 16:10:39 | *****APPROVED***** | | | | THE PROVISO COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEW | | HAVE BEEN ADDRESSED; PLAN SHEETS A1.1, A2.1, A3.1, AND | | E2 WERE STAMPED, INITIALED, AND DATED. | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2009-06-22 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2009-06-22 |
Time |
14:34 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2009-06-22 |
Time |
14:26 |
Sent To |
|
|
Notes |
2009-06-22 14:28:39 | *****PROVISO***** | | | | 1. STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241 - 2004 | | EDITION. | | | | 2. ON SHEET A3.1, GENERAL NOTE #8 AND #9 REFERENCES | | FLORIDA FIRE PREVENTION CODE - 2004 EDITION. CORRELATE | | TO CURRENT EDITION AS CORRECTLY SHOWN ON SHEET T UNDER | | CODES. | | | | 3. ON SHEET A3.1, AS PER BUILDING EXAMINER'S | | RED-LINING, THE NEW FIRE RATED DOOR (DOOR A) SHALL BE | | 45 MINUTES. | | | | 4. WILL THE SCOPE OF WORK HAVE CAUSE FOR THE SPRINKLER | | HEADS TO BE REMODELED IN ANY MANNER? IF SO, PROVIDE A | | LAYOUT OF THE FIRE SPRINKLER. (THEY MAY BE SHOWN ON | | SHEET A2.1, REFLECTED CEILING PLAN). | | | | | | THE APPROPIATE PLAN SHEET(S) TO BE FIRE-STAMPED WHEN | | THE ABOVE AS WELL AS OTHER PLAN EXAMINER(S)' COMMENTS | | HAVE BEEN ADDRESSED | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
|
Date |
2009-10-20 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2009-10-20 |
Time |
13:24 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2009-10-20 |
Time |
13:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2009-07-15 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2009-07-15 |
Time |
14:53 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2009-07-15 |
Time |
14:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2009-07-06 |
Time |
|
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-06-08 |
Time |
14:23 |
Sent To |
PC |
|
Notes |
2009-06-08 14:24:29 | TO B11 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2009-11-06 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2009-11-06 |
Time |
09:56 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2009-11-06 |
Time |
09:56 |
Sent To |
|
|
Notes |
2009-11-06 09:56:43 | REVISED M1 DELTA 4, M2 DELTA 1 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2009-07-06 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2009-07-06 |
Time |
15:59 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2009-07-06 |
Time |
15:59 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2009-06-17 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2009-06-17 |
Time |
16:02 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2009-06-17 |
Time |
16:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
2009-06-23 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2009-06-23 |
Time |
10:55 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2009-06-23 |
Time |
10:55 |
Sent To |
|
|
Notes |
|
|