Plan Review Stops For Permit 09060146 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2009-09-23 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2009-09-23 |
Time |
15:54 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2009-09-23 |
Time |
15:54 |
Sent To |
|
|
Notes |
2009-09-23 15:55:20 | REVISION #2 DATED 9/10/9, SHEET A1.1 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2009-07-22 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2009-07-22 |
Time |
18:31 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2009-07-22 |
Time |
18:31 |
Sent To |
|
|
Notes |
2009-07-22 18:31:26 | PASSED W/REDLINE, 45 MIN DOORS IN TENANT SEPARATION | | WALL |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2009-06-15 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2009-06-15 |
Time |
20:23 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2009-06-15 |
Time |
20:23 |
Sent To |
|
|
Notes |
2009-06-15 20:23:36 | PASSED W/REDLINE, 45 MIN DOOR AT TENANT SEPARATION |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2009-10-28 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-10-28 |
Time |
08:20 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-10-28 |
Time |
08:20 |
Sent To |
|
|
Notes |
2009-10-28 08:20:14 | ** DENIED ** | | | | SPEC SPACE #5 ON FLOOR 6. | | | | 1) NOTE: SHEET E-1 DOES NOT ACTUALLY INDICATE ANY | | REVISION IN THE TITLE BLOCK OR ON THE PLANS. | | SHEET E-2 DOES CONTAIN A REVISION #3 IN THE TITLE BLOCK | | HOWEVER NO REVISION OR #3 CAN BE LOCATED ON THE PLANS. | | SHEET E-3 DOES CONTAIN A REVISION #3 ON THE TITLE | | BLOCKS AND A TRIANGLE #3 ON PLANS HOWEVER THE PLANS | | WERE NOT ACTUALLY REVISED. THE PLANS HAVE NO CHANGES | | THAT COULD BE FOUND. | | SHEETS E-1, 2, AND 3 WERE STAMPED INADVERTENTLY AND ARE | | SINCE VOIDED. | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | CONTACT THIS REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2009-07-21 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-07-21 |
Time |
19:41 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-07-21 |
Time |
19:41 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2009-06-18 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-06-18 |
Time |
08:35 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-06-18 |
Time |
08:35 |
Sent To |
|
|
Notes |
2009-06-18 08:35:31 | | | | | | | | | ** DENIED PLANS * | | | | 1) NOTE: THE ELECTRICAL PLANS NEED TO STATE THE | | FOLLOWING MINIMUM CODES. | | PLEASE BE SURE THE FOLLOWING ARE STATED ON ELECTRICAL | | PLANS. | | 2007 FBC W/ 2009 AMENDMENTS. | | 2006 NFPA-101 ( PLANS STATE 2007 FOR THIS CODE) | | 2002 NFPA-72 (OK) | | 2006 NFPA-1 | | 2005 NFPA-70 ( PLANS STATE 2007) PLEASE BE ADVISED EVEN | | ONCE THE CODE CHANGE GOES INTO AFFECT THE IT WILL BE | | THE 2008 NEC. | | | | PER: FBC CHAPTER 35, FS 553.73, FAC 69A-60.004, .003 | | | | 2) NOTE: PLEASE SEE 13-415.AB.5 AND 13-415.AB.5.1 FOR | | LIGHTING PERFORMANCE CALCULATIONS. THE SECTION WHICH | | USED TO ALLOW TRADE OFFS FOR OTHER AREAS IS NO LONGER | | IN THE CODE. THE ALLOWANCE FOR SCONCES, CHANDELIERS ETC | | ARE ALSO NOT IN THE CODE. | | PLANS SHOW CALCULATIONS FOR MOST AREAS HOWEVER SOME ARE | | IN QUESTION. | | FOR EXAMPLE: ROOM 631 MISSING FROM CALCULATIONS. | | FOR EXAMPLE: SQ FT FOR AREA629 EXCEED SQ FT ON PLANS. | | | | 3) NOTE: PLEASE INCLUDE ALL DEVICE LOCATIONS, HEIGHTS, | | AND MINIMUM LEVELS PER FBC 11-4.28.1,.2 AND .3. | | THERE ARE SOME DEVICES ON PLANS HOWEVER NO DETAILS OR | | INFORMATION ON SYMBOL LEGEND. | | | | 4) NOTE: PLEASE CLARIFY WHY PANEL 6-OHP IS SHOWN. | | FBC 106.1.1, 106.1.2 FOR ADDITIONAL INFORMATION. | | NEC 408,240, | | | | | | | | | | | | | | ** IMPORTANT ** | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED | | INTO TWO SETS/FOLDERS/BINDERS ETC. | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | SHOULD BE SUBMITTED FOR REFERENCE. | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | ANY DELAYS. | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | CONTACT THIS REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2009-07-22 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2009-07-22 |
Time |
15:31 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2009-07-22 |
Time |
15:17 |
Sent To |
B |
|
Notes |
2009-07-22 15:31:11 | *****APPROVED***** | | | | THE COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEW HAVE | | BEEN ADDRESSED; PLAN SHEETS A1.1, A2.1, A3.1, AND E2 | | WERE STAMPED, INITIALED, AND DATED. | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2009-06-19 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2009-06-19 |
Time |
14:51 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2009-06-19 |
Time |
13:59 |
Sent To |
|
|
Notes |
2009-06-19 14:49:45 | *****DENIED***** | | | | 1. ON SHEET T, A WHITE-OUTED AREA IN THE PROJECT DATA | | IS SHOWN. BE ADVISED THAT THE PLANS SHALL BE PRESENTED | | WITH NO INK, PENCIL, AND/OR ANY OTHER MARKINGS. | | | | 2. ON SHEET A3.1, GENERAL NOTE #8 AND #9 REFERENCES | | FLORIDA FIRE PREVENTION CODE - 2004 EDITION. CORRELATE | | TO CURRENT EDITION AS CORRECTLY SHOWN ON SHEET T UNDER | | CODES. | | | | 3. PROVIDE A LAYOUT OF THE FIRE SPRINKLER HEADS FOR THE | | PROJECT SITE. (THEY MAY BE SHOWN ON SHEET A2.1 | | REFLECTED CEILING PLAN. | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | LETTER INDICATING WHERE EACH COMMENT WAS ADDRESSED | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2009-10-20 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2009-10-20 |
Time |
12:46 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2009-10-20 |
Time |
12:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2009-09-15 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2009-09-15 |
Time |
16:36 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2009-09-15 |
Time |
16:36 |
Sent To |
|
|
Notes |
2009-09-15 16:39:12 | SENT TO SHILL. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2009-07-15 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2009-07-15 |
Time |
14:55 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2009-07-15 |
Time |
14:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2009-07-06 |
Time |
|
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-06-08 |
Time |
14:19 |
Sent To |
PC |
|
Notes |
2009-06-08 14:20:08 | TO B10 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2009-11-06 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2009-11-06 |
Time |
10:06 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2009-11-06 |
Time |
10:00 |
Sent To |
|
|
Notes |
2009-11-06 10:06:07 | REVISED M1 DELTA 5, M2 DELTA 1 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2009-07-06 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2009-07-06 |
Time |
15:51 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2009-07-06 |
Time |
15:49 |
Sent To |
PC |
|
Notes |
2009-07-06 15:51:15 | **PROVISO** | | REVISE PAGE M1 TO SHOW MISSING "D1" MOTORIZED VOLUME | | DAMPERS TO CORRESPOND WITH DETAIL ON PAGE M2 FOR SMOKE | | CONTROL SYSTEM. | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | RONALD J. REGUEIRO | | 561.805.6719 | | [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2009-06-17 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2009-06-17 |
Time |
16:00 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2009-06-17 |
Time |
15:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
2009-06-23 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2009-06-23 |
Time |
10:54 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2009-06-23 |
Time |
10:53 |
Sent To |
|
|
Notes |
|
|