Plan Review Details - Permit 09060089
Plan Review Stops For Permit 09060089 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2009-06-25 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2009-06-25 |
Time |
19:16 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2009-06-25 |
Time |
19:16 |
Sent To |
|
|
Notes |
2009-06-25 19:16:29 | REDLINED PER CONTRACTOR | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2009-06-25 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2009-06-25 |
Time |
19:09 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2009-06-25 |
Time |
19:09 |
Sent To |
|
|
Notes |
2009-06-25 19:16:02 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2007 | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | FROM PREVIOUS LIST: | | | | 2. ACCORDION SHUTTERS, TOP CONNECTION, 10" SPACING | | SPECIFIED BUT THIS IS FOR 60PSF (9" REQUIRED FOR | | PRESSURE GREATER THAN 60PSF). | | | | ANCHOR SPACING REVISED TO STATE "NA". THIS INFORMATION | | IS REQUIRED. | | | | NEW COMMENT: | | | | 1ST INSTALL SCHEDULE ANCHOR SPACING FOR CLEAR PANELS | | WAS BLANK. NOW IT STATES 6". -59PSF REQUIRES USE OF | | 120MPH ROW (CANNOT USE -54, TOO LOW), BUT 47 HAS BEEN | | HIGHLIGHTED. 120 PSF REQUIRES 3.7" SPACING. | | | | SHUTTER MOUNTING CONNECTION TYPE STATES "NA;" THIS | | SHOULD SPECIFY ANCHOR DETAIL CORRELATING WITH ANCHOR | | CHARTS. IT APPEARS YOU ARE USING C2. | | | | IF YOU NEED ASSISTANCE WITH THE FORM, PLEASE HAVE THE | | QUALIFIER CONTACT ME TO SCHEDULE A MEETING. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2009-06-10 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2009-06-10 |
Time |
08:37 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2009-06-10 |
Time |
08:37 |
Sent To |
|
|
Notes |
2009-06-10 08:41:51 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2007 | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | 1. COMPLETE THE SAMPLE INSTALLATION SCHEDULE OR PROVIDE | | ALL INFORMATION TO SHOW CODE COMPLIANCE IN ANOTHER | | FORMAT, FBC*106, FBC R301, FBC1609. TWO SETS REQUIRED. | | THIS FORM IS AVAILABLE IN THE LOBBY OR ON THE INTERNET | | AT | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_ | | INSTALLATION.PDF | | | | THE ANCHOR SPACING FOR CLEAR PANELS STATES "NA"; THIS | | INFORMATION IS REQUIRED. | | | | 2. ACCORDION SHUTTERS, TOP CONNECTION, 10" SPACING | | SPECIFIED BUT THIS IS FOR 60PSF (9" REQUIRED FOR | | PRESSURE GREATER THAN 60PSF). | | | | 3. PLEASE CLARIFY EDGE DISTANCE. FOR INSTANCE, OPENING | | 18 STATES 3", BUT IF THE SUBSTRATE IS WOOD, 3" EDGE | | DISTANCE WOULD NOT ALLOW THE ANCHOR TO MEET THE MINIMUM | | EMBEDMENT REQUIREMENT. UNLESS PLYWOOD SUBSTRATE IS | | ALLOWED FOR THE SPECIFIED SHUTTER CONNECTION MOUNTING | | TYPE, 3/4" EDGE DISTANCE IS REQUIRED. | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2009-06-10 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2009-06-10 |
Time |
08:42 |
Rev Time |
0.00 |
Received By |
shill |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2009-06-04 14:32:37 | MISC 1 |
|
|
|