Plan Review Details - Permit 09060076
Plan Review Stops For Permit 09060076
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2009-12-08 Cont ID  
Sent By jwitmer Date 2009-12-08 Time 15:14 Rev Time 1.00
Received By jwitmer Date 2009-12-08 Time 15:14 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2009-10-01 Cont ID  
Sent By jwitmer Date 2009-10-01 Time 15:57 Rev Time 0.50
Received By jwitmer Date 2009-10-01 Time 15:30 Sent To  
Notes
2009-10-01 15:48:04BUILDING PLAN REVIEW
 PERMIT: 09060076
 ADD: 1335 OKEECHOBEE RD SUITE# 1000
 CONT: ATLANTIC GENERAL CONTRACTING
 TEL: (561)434-4171
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 2ND REVIEW
 ACTION: DENIED
  
 NO CHANGE IN INFORMATION!
  
 1) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER
 MARCH 1ST, 2009 SHALL BE REVIEWED TO THE 2007 FBC
 BUILDING WITH 2009 SUPPLEMENTS. PLEASE UPDATE PLANS TO
 ALSO INCLUDE THE 2007 EXISTING BUILDING CODE, CHAPTER
 10 ADDITIONS (MEZZANINE ADDING FUEL LOADS) .
  
 2) 110.2* W. P. B. ADMINISTRATIVE CODE, INFORMATION
 THAT IS REQUIRED FOR RECORD KEEPING & FOR CERTIFICATE
 OF OCCUPANCY:
 A) THE EDITION OFTHE CODE UNDER WHICH THE PROJECT IS
 DESIGNED.
 2007 FL BUILDING CODE, EXISTING BUILDING, ADDING A
 MEZANINE CONSTITUTES AN ADDITION SEE ASSOCIATED
 CHAPTERFOR ADDITIONS.
 B) THE TYPE OF CONSTRUCTION (FOR THE EXISTING BUILDING)
 AS DEFINED IN CHAPTER 5, TABLE 503, CHAPTER 6, TABLE
 601.
 C) PLANS INDICATE THERE IS A FIRE SPRINKLER SYSTEM, IS
 IT A REQUIRED SYSTEM FOR AREA INCREASES IN THE
 BUILDING?
 D) PLANS INDICATE THE OCCUPANCY TYPE TO BE A STORAGE
 OCCUPANCY, S1 OR S2?
  
 3) THE PLAN INDICATES THE MEZZANINE LEVEL OCCUPANCY
 SHALL BE USED FOR STORAGE.
  
 3A) 110.4.2 STORAGE & FACTORY- INDUSTRIAL OCCUPANCIES.
 IT SHALL BE THE RESPONSIBILITY OF THE OWNER, AGENT,
 PROPIETOR OR OCCUPANT OF GROUP S AND GROUP F
 OCCUPANCIES, OR ANY OCCUPANCY WHERE EXCESSIVE FLOOR
 LOADING IS LIKELY TO OCCUR, TO EMPLOY A COMPETENT
 ARCHITECT OR ENGINEER IN COMPUTING THE SAFE FLOOR LOAD
 CAPACITY. ALL SUCH COMPUTATIONS SHALL BE ACCOMPANIED BY
 AN AFFADAVIT FROM THE ARCHITECT OR ENGINEER STATING THE
 SAFE ALLOWABLE FLOOR LOADS ON EACH FLOOR IN POUNDS PER
 SQ FT.THE
 COMPUTATIONS & AFFADAVIT SHALL BE FILED AS A PERMANENT
 RECORD OF THE BLDG DEPT.
  
 3B) 110.4.3.SIGNS REQUIRED. IN EVERY BUILDING OR PART
 OF A BUILDING USED FOR STORAGE, INDUSTRIAL OR HAZARDOUS
 PURPOSES, THE SAFE FLOOR LOADS, AS REVIEWED BY THE
 BUILDING OFFICIAL ON THE PLAN, SHALL BE MARKED ON
 PLATES OF APPROVED DE SIGN WHICH SHALL BE SUPPLIED &
 SECURELY AFFIXED BY THE OWNER OF THE BUILDING IN A
 CONSPICUOUS PLACE IN EACH STORY TO WHICH THEY RELATE.
 SUCH PLATES SHALL NOT BE REMOVED OR DEFACED, & IF LOST,
 REMOVED THE OWNER OF THE BUILDING SHALL REPLACE THEM.
  
 4) NO PLANS WERE SUBMITTED FOR THE STRUCTURAL FRAMING
 OF THE MEZANINE NOR STAIRWAY OR FOR LOADING OF THE
 MEZZANINE LEVEL.
 106.3.5 MINIUMUM PLAN CRITERIA FOR COMMERCIAL
 BUILDINGS.
 NOT HAVING BUILDING INFORMATION TYPE , FIRE RETARDANT
 CONSTRUCTION MAY ALSO BE A FACTOR WITH A PLYWOOD FLOOR.
  
 5) PLANS INDICATE THE BUILDING HAS FIRE SPRINKLER
 SYSTEM ALREADY BUT NO PLANS WERE SUBMITTED FOR FIRE
 SPRINKLERS BENEATH THE MEZZANINE LEVEL.
  
 6) GUARD RAILS, PLEASE PROVIDE COMPLIANCE WITH:
 618.4.6.1 RAILINGS, STAIR-RAILINGS AND OTHER SIMILAR
 SAFEGUARDS SHALL BE DESIGNED TO RESIST A LOAD OF 50
 POUNDS PER LINEAL FOOT (74 KG/M) OR A CONCENTRATED LOAD
 OF 200 POUNDS (690 N) APPLIED IN ANY DIRECTION AT THE
 TOP OF SUCH BARRIERS AT ANY LOCATION ON THE SAFEGUARD,
 WHICHEVER CONDITION PRODUCES THE MAXIMUM STRESSES. THE
 REACTIONS AND STRESSES CAUSED BY THE ABOVE REFERENCED
 UNIFORM AND CONCENTRATED LOADS SHALL BE CONSIDERED NOT
 BE ACTING SIMULTANEOUSLY.
  
 7) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 NOTE: A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME,
 AS A RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
 ON REQUESTED ADDITIONAL COMMENTS MAY APPEAR THAT WERE
 NOT PART OF THIS REVIEW.
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)659-8026
 E-MAIL: [email protected]
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2009-06-19 Cont ID  
Sent By jwitmer Date 2009-06-19 Time 16:00 Rev Time 1.00
Received By jwitmer Date 2009-06-19 Time 15:08 Sent To  
Notes
2009-06-19 16:26:31BUILDING PLAN REVIEW
 PERMIT: 09060076
 ADD: 1335 OKEECHOBEE RD SUITE# 1000
 CONT: ATLANTIC GENERAL CONTRACTING
 TEL: (561)434-4171
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
 1) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER
 MARCH 1ST, 2009 SHALL BE REVIEWED TO THE 2007 FBC
 BUILDING WITH 2009 SUPPLEMENTS. PLEASE UPDATE PLANS TO
 ALSO INCLUDE THE 2007 EXISTING BUILDING CODE, CHAPTER
 10 ADDITIONS (MEZZANINE ADDING FUEL LOADS) .
  
 2) 110.2* W. P. B. ADMINISTRATIVE CODE, INFORMATION
 THAT IS REQUIRED FOR RECORD KEEPING & FOR CERTIFICATE
 OF OCCUPANCY:
 A) THE EDITION OFTHE CODE UNDER WHICH THE PROJECT IS
 DESIGNED.
 2007 FL BUILDING CODE, EXISTING BUILDING, ADDING A
 MEZANINE CONSTITUTES AN ADDITION SEE ASSOCIATED
 CHAPTERFOR ADDITIONS.
 B) THE TYPE OF CONSTRUCTION (FOR THE EXISTING BUILDING)
 AS DEFINED IN CHAPTER 5, TABLE 503, CHAPTER 6, TABLE
 601.
 C) PLANS INDICATE THERE IS A FIRE SPRINKLER SYSTEM, IS
 IT A REQUIRED SYSTEM FOR AREA INCREASES IN THE
 BUILDING?
 D) PLANS INDICATE THE OCCUPANCY TYPE TO BE A STORAGE
 OCCUPANCY, S1 OR S2?
  
 3) THE PLAN INDICATES THE MEZZANINE LEVEL OCCUPANCY
 SHALL BE USED FOR STORAGE.
  
 3A) 110.4.2 STORAGE & FACTORY- INDUSTRIAL OCCUPANCIES.
 IT SHALL BE THE RESPONSIBILITY OF THE OWNER, AGENT,
 PROPIETOR OR OCCUPANT OF GROUP S AND GROUP F
 OCCUPANCIES, OR ANY OCCUPANCY WHERE EXCESSIVE FLOOR
 LOADING IS LIKELY TO OCCUR, TO EMPLOY A COMPETENT
 ARCHITECT OR ENGINEER IN COMPUTING THE SAFE FLOOR LOAD
 CAPACITY. ALL SUCH COMPUTATIONS SHALL BE ACCOMPANIED BY
 AN AFFADAVIT FROM THE ARCHITECT OR ENGINEER STATING THE
 SAFE ALLOWABLE FLOOR LOADS ON EACH FLOOR IN POUNDS PER
 SQ FT.THE
 COMPUTATIONS & AFFADAVIT SHALL BE FILED AS A PERMANENT
 RECORD OF THE BLDG DEPT.
  
 3B) 110.4.3.SIGNS REQUIRED. IN EVERY BUILDING OR PART
 OF A BUILDING USED FOR STORAGE, INDUSTRIAL OR HAZARDOUS
 PURPOSES, THE SAFE FLOOR LOADS, AS REVIEWED BY THE
 BUILDING OFFICIAL ON THE PLAN, SHALL BE MARKED ON
 PLATES OF APPROVED DE SIGN WHICH SHALL BE SUPPLIED &
 SECURELY AFFIXED BY THE OWNER OF THE BUILDING IN A
 CONSPICUOUS PLACE IN EACH STORY TO WHICH THEY RELATE.
 SUCH PLATES SHALL NOT BE REMOVED OR DEFACED, & IF LOST,
 REMOVED THE OWNER OF THE BUILDING SHALL REPLACE THEM.
  
 4) NO PLANS WERE SUBMITTED FOR THE STRUCTURAL FRAMING
 OF THE MEZANINE NOR STAIRWAY OR FOR LOADING OF THE
 MEZZANINE LEVEL.
 106.3.5 MINIUMUM PLAN CRITERIA FOR COMMERCIAL
 BUILDINGS.
 NOT HAVING BUILDING INFORMATION TYPE , FIRE RETARDANT
 CONSTRUCTION MAY ALSO BE A FACTOR WITH A PLYWOOD FLOOR.
  
 5) PLANS INDICATE THE BUILDING HAS FIRE SPRINKLER
 SYSTEM ALREADY BUT NO PLANS WERE SUBMITTED FOR FIRE
 SPRINKLERS BENEATH THE MEZZANINE LEVEL.
  
 6) GUARD RAILS, PLEASE PROVIDE COMPLIANCE WITH:
 618.4.6.1 RAILINGS, STAIR-RAILINGS AND OTHER SIMILAR
 SAFEGUARDS SHALL BE DESIGNED TO RESIST A LOAD OF 50
 POUNDS PER LINEAL FOOT (74 KG/M) OR A CONCENTRATED LOAD
 OF 200 POUNDS (690 N) APPLIED IN ANY DIRECTION AT THE
 TOP OF SUCH BARRIERS AT ANY LOCATION ON THE SAFEGUARD,
 WHICHEVER CONDITION PRODUCES THE MAXIMUM STRESSES. THE
 REACTIONS AND STRESSES CAUSED BY THE ABOVE REFERENCED
 UNIFORM AND CONCENTRATED LOADS SHALL BE CONSIDERED NOT
 BE ACTING SIMULTANEOUSLY.
  
 7) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 NOTE: A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME,
 AS A RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
 ON REQUESTED ADDITIONAL COMMENTS MAY APPEAR THAT WERE
 NOT PART OF THIS REVIEW.
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)659-8026
 E-MAIL: [email protected]
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2009-12-03 Cont ID  
Sent By dpalmer Date 2009-12-03 Time 17:01 Rev Time 0.00
Received By dpalmer Date 2009-12-03 Time 17:01 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2009-10-10 Cont ID  
Sent By dpalmer Date 2009-10-10 Time 08:14 Rev Time 0.00
Received By dpalmer Date 2009-10-10 Time 08:14 Sent To  
Notes
2009-10-10 08:14:49** DENIED**
  
 1) NOTE: NEW LIGHTING AND EXISTING LIGHTING APPEAR TO
 MEET REQUIRED MINIMUMS HOWEVER NEW LIGHTING DOES NOT
 INDICATE HOW OR WHERE THESE WILL BE CONTROLLED?
 FBC 13-415.AB.1.1,.1.2
 NO CIRCUITING ON PLANS TO SHOW WHERE LIGHTS WOULD BE
 FED. SEE 700.12F FOR UNIT EMERGENCY LIGHT FIXTURES TO
 LOCAL LIGHTING BRANCH CIRCUIT.
  
 ** THE ABOVE COULD HAVE BEEN A PROVISO HOWEVER AS THERE
 ARE STILL BUILDING REVIEW COMMENTS THIS SHEET COULD NOT
 BE STAMPED OR GIVEN A PROVISO AT THIS TIME.
  
 **IMPORTANT**
 IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT
 TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO
 CONTACT THIS REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2009-06-18 Cont ID  
Sent By dpalmer Date 2009-06-18 Time 14:11 Rev Time 0.00
Received By dpalmer Date 2009-06-18 Time 14:11 Sent To  
Notes
2009-06-18 14:19:19 
 ** DENIED PLANS *
  
 1) NOTE: THE ELECTRICAL PLANS NEED TO STATE THE
 FOLLOWING MINIMUM CODES.
 PLEASE BE SURE THE FOLLOWING ARE STATED ON ELECTRICAL
 PLANS.
 2007 FBC W/ 2009 AMENDMENTS.
 2006 NFPA-101
 2002 NFPA-72
 2006 NFPA-1
 2005 NFPA-70
  
 PER: FBC CHAPTER 35, FS 553.73, FAC 69A-60.004, .003
  
  
 2) NOTE: PLEASE SEE 13-415.AB.5 AND 13-415.AB.5.1 FOR
 LIGHTING PERFORMANCE CALCULATIONS.
  
 3) NOTE: PLEASE INCLUDE ALL DEVICE LOCATIONS, HEIGHTS,
 AND MINIMUM LEVELS PER FBC 11-4.28.1,.2 AND .3. ONLY IF
 THERE IS FIRE ALARM PANEL AND/OR ANY DEVICES TO BE
 INSTALLED.
  
 4) NOTE: PLEASE PROVIDE LIGHTING FOR NORMAL AND
 EMERGENCY EGRESS FOR STAIRS. SHOW NEW OR EXISTING TO
 MEET NFPA- 101 2006, 7.8.1.3, 7.9.1.2, .2.2
 FAC 61G15-33.004
  
 5) NOTE: NEW LIGHTING CONTROLS SHALL MEET PRESCRIPTIVE
 13-415.AB.1.1,.1.2, .1.3
  
 6) NOTE: VALUE FOR SCOPE OF WORK SHALL BE APPLICABLE TO
 SCOPE. THE PREVIOUS PERMIT FOR THIS SCOPE WHICH WAS
 NEVER ISSUED WAS SUBSTANTIALLY HIGHER. PLEASE SEE FBC
 108.3 AS ADOPTED FOR VALUATION SHALL INCLUDE ALL LABOR,
 MATERIALS, DESIGN COST AND EQUIPMENT WHETHER OR NOT ANY
 OF THESE ARE OWNER SUPPLIED.
  
 7) NOTE: PLEASE PROVIDE LICENSING FOR KC HUBBARD AND
 ASSOCIATES. * DESIGNERS NOT LICENSED UNDER FS 481 OR
 471 ARE NOT PERMITTED TO DESIGN COMMERCIAL WORK PER
 481.229.
 THIS HAS BEEN CONFIRMED WITH THE PROSECUTING ATTORNEY
 FOR THE FLORIDA BOARD OF ARCHITECTS. PLANS MAY BE
 RETAINED.
  
  
  
  
  
  
 ** IMPORTANT **
 ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP
 FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE
 ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING.
 DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS.
 PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY
 ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS,
 SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED
 INTO TWO SETS/FOLDERS/BINDERS ETC.
 PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS
 SHOULD BE SUBMITTED FOR REFERENCE.
 THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID
 ANY DELAYS.
  
  
 IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT
 TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO
 CONTACT THIS REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2009-12-04 Cont ID  
Sent By mawillia Date 2009-12-04 Time 12:57 Rev Time 0.00
Received By mawillia Date 2009-12-04 Time 12:49 Sent To  
Notes
2009-12-04 12:56:03*****APPROVED*****
  
 THE COMMENT(S) FROM THE PREVIOUS REVIEW HAVE BEEN
 ADDRESSED; PLAN SHEET A1 STAMPED, INITIALED, AND DATED.
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2009-10-16 Cont ID  
Sent By mawillia Date 2009-10-16 Time 13:42 Rev Time 0.00
Received By mawillia Date 2009-10-16 Time 13:26 Sent To  
Notes
2009-10-16 13:32:03*****PARTIAL APPROVAL*****
  
  
 THE APPROPIATE PLAN SHEET TO BE FIRE-STAMPED WHEN THE
 PREVIOUS BELOW COMMENT AS WELL AS THE OTHER EXAMINERS'
 COMMENTS HAVE BEEN ADDRESSED:
  
 3. EFFECTIVE DECEMBER 31ST, 2008: NFPA 101, LIFE SAFETY
 CODE, 2006 EDITION SHALL BE REFERENCED. ADD CODE
 REFERENCE TO THE APPROPIATE SHEET
  
  
 TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE
 LETTER, INDICATING WHERE EACH ITEM WAS ADDRESSED
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2009-06-22 Cont ID  
Sent By mawillia Date 2009-06-22 Time 13:36 Rev Time 0.00
Received By mawillia Date 2009-06-22 Time 13:13 Sent To  
Notes
2009-06-22 13:22:08*****DENIED*****
  
  
 1. STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR
 DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241.
  
 2. HOW WILL THIS MEZZANINE IMPACT THE EXISTING FIRE
 SPRINKLER AND FIRE ALARM DEVICES. SPRINKLERS ARE SHOWN,
 HOWEVER PROTECTION NEEDED ABOVE AND BELOW THE MEZZANINE
 FLOOR.
  
 3. EFFECTIVE DECEMBER 31ST, 2008: NFPA 101, LIFE SAFETY
 CODE, 2006 EDITION SHALL BE REFERENCED.
  
  
 TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE
 LETTER, INDICATING WHERE EACH ITEM WAS ADDRESSED
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2009-11-17 Cont ID  
Sent By btrobaug Date 2009-11-17 Time 16:16 Rev Time 0.00
Received By btrobaug Date 2009-11-17 Time 16:16 Sent To  
Notes
2009-11-17 16:16:52B7

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2009-09-30 Cont ID  
Sent By jgomez Date 2009-09-30 Time 08:57 Rev Time 0.00
Received By jgomez Date 2009-09-30 Time 08:50 Sent To  
Notes
2009-09-30 08:51:13SENT TO BOB #10.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-06-22 Cont ID  
Sent By mawillia Date 2009-06-22 Time 13:41 Rev Time 0.00
Received By mawillia Date 2009-06-03 Time 16:08 Sent To  
Notes
2009-06-04 16:08:23TO B2

Review Stop Z ZONING
Rev No 2 Status P Date 2009-10-05 Cont ID  
Sent By eschneid Date 2009-10-05 Time 10:58 Rev Time 0.50
Received By eschneid Date 2009-10-05 Time 10:58 Sent To  
Notes
2009-10-05 10:58:59APPROVED 690 SQ. FT. OF STORAGE MEZZANINE.

Review Stop Z ZONING
Rev No 1 Status F Date 2009-06-08 Cont ID  
Sent By eschneid Date 2009-06-08 Time 14:33 Rev Time 0.50
Received By eschneid Date 2009-06-08 Time 14:33 Sent To  
Notes
2009-06-08 14:40:29FAILED
  
 1) THIS PERMIT IS FOR THE "COMPLETION OF MEZZANINE"
 THAT WAS ORIGINALLY SUBMITTED UNDER PERMIT NO.
 08010311. PERMIT NO. 08010311 WAS NEVER ISSUED.
  
 2) NO SHOP DRAWINGS, SPECIFICATIONS, ETC. WERE
 SUBMITTED WITH THIS PERMIT APPLICATION.
  
 3) THE DRAWINGS INDICATE THAT THE MEZZANINE IS
 PLUS/MINUS 650 SQ. FEET. DUE TO THE PARKING
 REQUIREMENTS FOR THE AUSTRALIAN TRADE CENTER, THE EXACT
 SIZE OF THE MEZZANINE IS REQUIRED.
  
 4) THE DIMENSIONS THAT ARE LISTED FOR THE MEZZANINE
 SHOW A MEZZANINE OF 715 SQ. FEET ONCE THE STAIRS AND
 LANDING ARE NOT INCLUDED. RECTIFY THE DIFFERING SQ.
 FEET AND SHOW ACCURATE DIMENSIONS.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.