2009-06-19 14:03:50 | BUILDING PLAN REVIEW | | PERMIT: 09060005 | | ADD: 1801 S FLAGLER DR UNIT 1411 | | CONT: MARYJULI CONSTRUCTION | | TEL: (561)386-6032 | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | W/ 2009 FBC SUPPLEMENTS | | * WEST PALM BEACH AMENDMENTS | | | | REVIEW | | ACTION: DENIED | | | | 1) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER | | MARCH 1ST, 2009 SHALL BE REVIEWED TO THE 2007 FBC | | BUILDING WITH 2009 SUPPLEMENTS. | | | | 2) SHEET # 1 MISCELLANEOUS NOTE#1 INDICATES THIS TO BE | | A R-4 OCCUPANCY WHEREAS IN THE LISTED ON THE SAME SHEET | | CONSTRUCTION INFORMATION INDICATES A R2 OCCUPANCY. | | TABLE 803.5. | | | | 3) SHEET 4 INDICATES THE USE OF SOFFITS BUT THERE IS NO | | INFORMATION AS TO MATERIALS, FRAMING OR ATTACHMENT TO | | THE DECK ABOVE? ADDITIONAL INFORMATION REQUIRED | | 106.1.2. | | | | JIM WITMER C. B. O. | | BUILDING PLAN REVIEW II | | | | TEL: (561)805-6715 | | FAX: (561)805-6731 | | E-MAIL: [email protected] | | SURVEY: | | WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2009-08-11 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-08-11 |
Time |
14:34 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-08-11 |
Time |
14:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2009-07-04 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-07-04 |
Time |
12:10 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-07-04 |
Time |
12:10 |
Sent To |
|
|
Notes |
2009-07-04 12:10:18 | | | ** DENIED PLANS 2ND REVIEW ** | | SOME NOTES FROM PREVIOUS REVIEW STILL NOT ADDRESSED. | | SOME NEW NOTES BASED ON SOME INFORMATION SHOWN NOT ON | | PREVIOUS PLANS. | | AS STATED ON PREVIOUS REVIEW, IF THERE ARE QUESTIONS OR | | COMMENTS OR IF THERE ARE ANY NOTES NOT TYPED IN A CLEAR | | MANNER PLEASE CALL. NO CONTACT WAS MADE FROM LAST | | REVIEW AND IT APPEARS PERHAPS SOME NOTES WERE NOT | | UNDERSTOOD. | | | | 1) NOTE: AS THE SCALE IS VERY SMALL AND THERE IS A LOT | | OF ITEMS SHOWN ON PLANS. AS STATED ON PREVIOUS REVIEW | | PLANS ARE CONGESTED. CIRCUITING IS NOT CLEAR. SOME | | ITEMS STILL DO NOT INDICATE CIRCUITING. SEE REDLINED | | PLANS. OTHERS SUCH AS CIRCUIT 2A, 9B, 7B AND 12A ARE | | STATED AS GENERAL LIGHTING. PLEASE SEE COMMENTARY FROM | | THE 2005 NEC IN 408.4. THESE NEED TO BE SPECIFIC TO | | ROOMS AND AREAS IN WHICH THEY FEED. LIVING ROOM | | LTS/RECEPTS, KITCHEN LIGHTS ETC OR OTHER DESIGNATION. | | 408.4, 210.52, 210.11 ETC | | | | 2) NOTE: MINIMUM OF TWO SMALL APPLIANCE CIRCUITS IS | | REQUIRED PER 210.52B1, 210.11C1, 220.53. LIGHTING | | CIRCUIT 7B IS SHOWN CONNECTED TO RECEPTACLE IN ONE AREA | | WHICH IS NOT PERMITTED. | | THE KITCHEN PLANS ARE NOT CLEAR. | | | | 3) NOTE: PLEASE SEE GUEST BATH. THIS ROOM SHOWS THE | | CIRCUIT TO GFI AS 5B. THIS IS SHOWN AS A BEDROOM | | CIRCUIT ON PANEL SCHEDULE WITH #14AWG AND 15AMP | | BREAKER. THIS IS NOT PERMITTED. PLEASE SEE 210.11C3 AS | | BATH GFI CIRCUITS/RECEPTACLES ARE ONLY PERMITTED TO BE | | CIRCUITED ONE OF TWO WAYS. IN EITHER CASE THEY ARE ALSO | | REQUIRED TO BE 20AMP AND #12. | | | | 4) NOTE: PLEASE SEE 210.52 AS SOME RECEPTACLES ARE | | MISSING FOR WALL SPACES. SEE ONE SET OF PLANS WHICH ARE | | REDLINED. | | WALL IN MASTER BEDROOM, WALL IN OTHER GUEST ROOM. | | | | 5) NOTE: PLEASE SEE S1 AND S2 NOTES ON PLANS. THE | | SYMBOL LEGEND STATES S 1 AND S2 ARE SMOKE ALARMS, YET | | THE NOTES STATE S2 IS A SMOKE DETECTOR WHICH IS NOT THE | | SAME. S2 NOTE ALSO STATES ONLY TO BE INTERCONNECTED | | WHEN WITHIN 20FT OF COOKING APPLIANCES. | | | | A) ALL SMOKE DETECTION DEVICES WHETHER OR NOT SMOKE | | ALARMS OR DETECTORS ARE REQUIRED TO BE INTERCONNECTED | | IN THIS R OCCUPANCY. | | B) ALL SHALL BE CIRCUITED SINGLE STATION INTERCONNECTED | | AND ON ONE OF THE ARC FAULT PROTECTED CIRCUITS PER | | 210.12. SINCE S2 OUTSIDE SLEEPING ROOM IS REQUIRED TO | | BE INTERCONNECTED WITH THE S1 UNITS, THIS MUST ALSO BE | | ON THE SAME AFCI CIRCUIT. | | | | NFPA-72 11.8.3,11.5.1, NEC 210.12. | | | | | | | | ** ONLY NOTED FOR INFORMATION. LOW VOLTAGE SHOWN ON | | PLANS WILL BE REQUIRED TO BE UNDER SEPARATE PERMIT. MAY | | USE THESE PLANS AS A REFERENCE FOR TURN AROUND PERMIT. | | | | | | ** IMPORTANT ** | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED | | INTO TWO SETS/FOLDERS/BINDERS ETC. | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | SHOULD BE SUBMITTED FOR REFERENCE. | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | ANY DELAYS. | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | CONTACT THIS REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2009-06-17 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-06-17 |
Time |
15:16 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-06-17 |
Time |
15:16 |
Sent To |
|
|
Notes |
2009-06-17 15:16:45 | | | | | | | | | ** DENIED PLANS * | | | | 1) NOTE: THE ELECTRICAL PLANS NEED TO STATE THE | | FOLLOWING MINIMUM CODES. | | PLEASE BE SURE THE FOLLOWING ARE STATED ON ELECTRICAL | | PLANS. | | 2007 FBC W/ 2009 AMENDMENTS. | | 2006 NFPA-101 ( PLANS STATE 2003 FOR THIS CODE) | | 2002 NFPA-72 | | 2006 NFPA-1 | | 2005 NFPA-70 ( PLANS DO NOT GIVE YEAR) | | | | PER: FBC CHAPTER 35, FS 553.73, FAC 69A-60.004, .003 | | | | 2) NOTE: PLEASE SUBMIT ELECTRICAL PLANS WITHOUT THE | | MECHANICAL SHADED OVER THE ELECTRICAL DETAILS. SOME | | ITEMS ARE NOT CLEAR TO BE REVIEWED FOR CODE COMPLIANCE. | | THE KITCHEN PLANS FOR EXAMPLE ARE VERY CONGESTED AND | | NOT EASILY READ FOR CODE COMPLIANCE VERIFICATION OF | | 210.52C1-5 FOR EXAMPLE. | | FBC 106.1.1 FOR CLARITY AND QUALITY OF SUBMITTED PLANS. | | NEC, 300,210,ETC | | | | 3) NOTE: PLEASE SEE NFPA-72 FOR DEFINITIONS OF SMOKE | | DETECTION DEVICES. PER THE SYMBOL LEGEND THE PLANS | | STATE THERE IS GOING TO BE SMOKE DETECTORS. SMOKE | | DETECTORS ARE DEVICE WHICH DETECT HOWEVER DO NOT SOUND | | AN ALARM. IF THESE ARE INDEED SMOKE DETECTORS, PLEASE | | SUBMIT MORE DETAILS ON THE COMPLETE SYSTEM SHOWING THE | | HORNS, STROBES PANEL OR SOUNDING DEVICES TO ALERT THE | | OCCUPANT. | | PLEASE SEE NFPA-72 11.5.1.1, 11.8.3 | | ** PLEASE SEE NFPA-72 DEFINITIONS OF SMOKE ALARMS. IF | | THESE ARE SMOKE ALARMS WHICH DETECT AND SOUND AN ALARM | | PLEASE ADJUST PLANS ACCORDINGLY. | | | | 4) NOTE: PLEASE BE SURE TO SEE 210.4B FOR ANY DEVICES | | OR SINGLE YOKE BEING FED FROM MORE THAN ONE CIRCUIT. | | THIS MAY BE THE DISHWASHER/DISPOSAL WHICH WOULD REQUIRE | | A TWO POLE BREAKER. IT IS NOT CLEAR AT THIS TIME IF | | THIS IS THE SAME YOKE OR NOT. | | | | 5) NOTE: PLEASE SEE 422.13 AS WATER HEATER LOAD UNDER | | THE 2005 NEC IS NOW CONSIDERED A CONTINUOUS LOAD WHICH | | REQUIRES 125% TO BE FIGURED INTO THE CALCULATIONS. | | | | 6) NOTE: PLEASE SEE THE CODE SECTIONS REFLECTED ON THE | | LOAD CALCULATIONS ARE NOT FROM THE CURRENT EDITION OR | | EVEN PREVIOUS EDITION OF THE NEC. IN FACT PLANS STATE | | 202.32, 202.30. THERE IS NO SECTION 202 LOCATED IN | | NFPA70. EVEN IF THESE WERE MISPRINTS TO BE | | 220.30,220.32, THE CURRENT EDITION OF THE NEC WHICH IS | | THE ADOPTED 2005 DOES NOT CONTAIN THESE SECTIONS. | | PLEASE SEE NEW CODE WHICH WENT INTO AFFECT DECEMBER 8TH | | 2006. | | | | 7) NOTE: PLEASE SEE 210.52B1, 210.11C1, 220.53 AS EACH | | OF THE ONE OR MORE SMALL APPLIANCE CIRCUITS SHALL BE | | FIGURED AT 1500VA FOR EACH. NO LOAD IS SHOWN IN THE | | LOAD CALCULATIONS FOR THE DINING ROOM RECEPTACLE | | CIRCUIT. | | | | | | | | ** IMPORTANT ** | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED | | INTO TWO SETS/FOLDERS/BINDERS ETC. | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | SHOULD BE SUBMITTED FOR REFERENCE. | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | ANY DELAYS. | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | CONTACT THIS REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2009-08-12 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2009-08-12 |
Time |
11:10 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2009-08-12 |
Time |
10:54 |
Sent To |
B |
|
Notes |
2009-08-12 11:09:44 | *****APPROVED***** | | | | PLAN SHEETS 6 & 7 WERE STAMPED, INITIALED, AND DATED; | | SHEET 2 WAS PREVIOUSLY FIRE-STAMPED ON 7/20/2009. | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2009-07-20 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2009-07-20 |
Time |
13:25 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2009-07-20 |
Time |
13:06 |
Sent To |
|
|
Notes |
2009-07-20 13:21:42 | *****PROVISO***** | | | | THE COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEW HAS | | BEEN SATISFIED; PLAN SHEET 2 WAS STAMPED, INITIALED, | | AND DATED - HOWEVER SHEETS 6 & 7 ARE TO FIRE-STAMPED | | WHEN THE ELECTRICAL EXAMINER'S COMMENTS HAVE BEEN | | ADDRESSED | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2009-06-18 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2009-06-18 |
Time |
13:53 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2009-06-18 |
Time |
13:17 |
Sent To |
|
|
Notes |
2009-06-18 13:52:56 | *****DENIED***** | | | | | | 1. STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241 - 2004 | | EDITION. ADD COMMENT TO SHEET 2 (OF SEVEN). | | | | 2. EFFECTIVE 12/31/2008, THE 2006 EDITION OF NFPA 101 | | SHALL BE REFERENCED. AMEND ELECTRICAL NOTE #1 AND FIRE | | PROTECTION NOTE #1 ON SHEET 7 (OF SEVEN). | | | | 3. THE SMOKE DETECTOR / SMOKE ALARM DEVICES AREN'T | | READILY VISIBLE DUE TO CLARITY OF PLANS AS SHOWN ON | | SHEET 6 (OF SEVEN). | | | | 4. INDICATE THE TYPE OF DEVICE THAT IS/ARE BEING AND OR | | WILL BE USED IN THE LIVING UNIT. BE ADVISED THAT SMOKE | | DETECTORS (SD) ARE TIED INTO THE BUILDING'S FIRE ALARM | | SYSTEM, WHEREAS SMOKE ALARMS (SA) SHALL SOUND ONLY | | WITHIN THE DWELLING UNIT AND SHALL NOT ACTUATE THE | | BUILDING FIRE ALARM SYSTEM, UNLESS OTHERWISE PERMITTED | | BY THE AUTHORITHY HAVING JURISDICTION (AHJ). | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | LETTER INDICATING WHERE EACH ITEM WAS ADDRESSED | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2009-08-26 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2009-08-26 |
Time |
09:28 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2009-08-26 |
Time |
09:25 |
Sent To |
|
|
Notes |
2009-08-26 09:30:46 | DUCT REVISION | 2009-08-26 09:28:42 | GAVE TO RON |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2009-07-29 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2009-07-29 |
Time |
09:01 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2009-07-29 |
Time |
09:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2009-07-01 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2009-07-01 |
Time |
09:35 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2009-07-01 |
Time |
09:35 |
Sent To |
|
|
Notes |
2009-07-01 09:36:14 | WAITING FOR BOB BOARD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2009-06-19 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2009-06-19 |
Time |
15:26 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2009-06-02 |
Time |
10:56 |
Sent To |
PC |
|
Notes |
2009-06-02 10:56:12 | TO B12 | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2009-08-31 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2009-08-31 |
Time |
16:44 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2009-08-31 |
Time |
16:44 |
Sent To |
|
|
Notes |
2009-08-31 16:44:57 | REVISED DUCT LAYOUT |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2009-08-05 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2009-08-05 |
Time |
09:27 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2009-08-04 |
Time |
16:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2009-07-13 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2009-07-13 |
Time |
16:28 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2009-07-13 |
Time |
16:26 |
Sent To |
|
|
Notes |
2009-07-13 16:28:52 | PREVIOUS COMMENTS ADDRESSED. PLANS NOT STAMPED DUE TO | | FAILED ELECTRICAL REVIEW AND MECHANICAL BEING ON THE | | SAME PAGE. MECHANICAL STAMPS WILL BE APPLIED TO PLANS | | ONCE ELECTRICAL REVIEW IS PASSED UNLESS SEPARATE SHEETS | | ARE SUBMITTED FOR EACH TRADE. | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | RONALD J. REGUEIRO | | 561.805.6719 | | [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2009-06-19 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2009-06-19 |
Time |
15:25 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2009-06-19 |
Time |
15:23 |
Sent To |
PC |
|
Notes |
2009-06-19 15:25:44 | REVIEW #: 1ST | | ACTION: DENIED | | | | FBC 2007 CODE FAMILY W/ 2009 SUPPLEMENTS | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | 1. PLEASE SHOW CFM QUANTITIES FOR EACH SUPPLY REGISTER | | ON PLANS IN ACCORDANCE WITH FBC-M 603.1 | | | | 2. NO BATHROOM EXHAUST IS SHOWN ON PLANS. EXHAUST IS | | REQUIRED IN THE BATHROOM PER FBC-EB 709.1 AND FBC-M | | 402.3.1. | | | | 3. NOTE #4 ON PAGE 6 CALLS FOR WASHER AND DRYER BUT NO | | SUCH APPLIANCES COULD BE FOUND ON PLANS. PLEASE CLARIFY | | IN ACCORDANCE WITH FBC-B 106.1.1. | | | | 4. SOME DUCT SIZES PROPOSED ON PAGE 6 WILL NOT FIT | | BASED ON THE SIZES OF SOFFITS SHOWN ON PAGE 3. PLEASE | | COORDINATE FLOOR PLANS TO ASSURE THE REQUIRED VOLUMES | | OF AIR CAN BE DELIVERED TO EACH SPACE IN ACCORDANCE | | WITH FBC-M 603.1. | | | | 5. PLEASE ENSURE PLANS ARE PROPERLY SIGNED, SEALED AND | | DATED IN ACCORDANCE WITH FS 481. | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | RONALD J. REGUEIRO | | 561.805.6719 | | [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2009-07-10 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2009-07-10 |
Time |
16:41 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2009-07-10 |
Time |
16:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2009-06-17 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2009-06-17 |
Time |
09:29 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2009-06-17 |
Time |
09:29 |
Sent To |
|
|
Notes |
2009-06-17 09:40:00 | DENIED | | REFERENCE: | | FBC-2007 W/2009 SUPPLEMENTS | | FLORIDA ADMINISTRATIVE CODE | | FLORIDA STATUTES | | | | 1. SHT 1 OF 7 GENERAL NOTES #1. THE PLANS FOR ALL | | APPLICATIONS FOR PERMIT ON OR AFTER MARCH 1 2009 SHALL | | BE DESIGNED TO THE FBC-2007 W/2009 SUPPLEMENTS. PLANS | | SHOW THE DESIGN TO BE UNDER THE FBC-2004 CODE. PLEASE | | UPDATE CYCLE. SECTIONS 106.1.1 & 110.1.2. | | | | 2. THE ADDRESS OF RECORD ON THE STATE OF FLORIDA DEPT | | OF PROFESSIONAL REGULATION, (DBPR), 7711 BROOKFIELD | | ROAD, CHEVY CHASE MD. MOST SHEETS HAVE A DIFFERENT | | ADDRESS, 1801 S FLAGLER DRIVE, WEST PALM BEACH. PLEASE | | ADD THE ADDRESS OF RECORD TO ALL SHEETS CONTAINING THE | | LOCAL ADDRESS. FAC 61G1-16.004(1) & FS 481.2055. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | ONE SET OF THEM LOOSELY ON TOP OF THE | | COLLATED PLANS TO BE REVIEWED. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
2009-06-04 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2009-06-04 |
Time |
15:27 |
Rev Time |
0.25 |
Received By |
eschneid |
Date |
2009-06-04 |
Time |
15:26 |
Sent To |
|
|
Notes |
|
|