Plan Review Details - Permit 09050385
Plan Review Stops For Permit 09050385
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2009-09-09 Cont ID  
Sent By rmcdouga Date 2009-09-09 Time 13:39 Rev Time 0.00
Received By rmcdouga Date 2009-09-09 Time 13:39 Sent To  
Notes
2009-09-09 13:43:35REVISIONS FOR REPLACING DOOR AND AND WINDOW ARE OK.
 ALSO REVISION FOR SC3 BASE PLATE AND FASTENING
 CLARIFICATION LETTERS ARE OK.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2009-08-17 Cont ID  
Sent By rmcdouga Date 2009-08-17 Time 10:38 Rev Time 0.00
Received By rmcdouga Date 2009-08-17 Time 10:38 Sent To  
Notes
2009-08-17 10:39:54SUBMITTED ENGINEERED SHOP DRAWINGS FOR HELICAL PIER
 INSTALLATION AS REQUIRED BY PROVISO.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2009-06-12 Cont ID  
Sent By rmcdouga Date 2009-06-12 Time 08:42 Rev Time 0.00
Received By rmcdouga Date 2009-06-12 Time 08:42 Sent To  
Notes
2009-06-12 08:46:03BUILDING PROVISO
  
 1) PRIOR TO INSTALLATION SUBMIT TWO SETS OF ENGINEERED
 SHOP DRAWINGS AND CALCULATIONS FROM THE SPECIALTY
 CONTRACTOR FOR THE HELICAL PIERS THAT WILL BE
 INSTALLED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2009-05-27 Cont ID  
Sent By rmcdouga Date 2009-05-27 Time 13:24 Rev Time 0.00
Received By rmcdouga Date 2009-05-27 Time 13:24 Sent To  
Notes
2009-05-27 15:06:552007 FBC
 LEVEL 2 ALTERATION
  
 DENIED BY BUILDING
  
 1) A MINIMUM OF TWO SETS OF PLANS ARE REQUIRED TO BE
 SUBMITTED FOR PERMIT. FBC 106.1* CITY AMENDMENTS.
  
 2) THE WRONG EDITION OF FBC IS SPECIFIED. THIS PROJECT
 IS UNDER THE 2007 FBC. PLEASE CORRECT.
  
 3) SPECIFY THE LEVEL OF ALTERATION ON THE PLANS. FBC
 EXISTING BUILDING SECTION 401.4
  
 4) ON SHEET A-2 STEEL COLUMN 2 IS MISLABELED AS S.C. 1
 ON THE FOUNDATION PLAN. PLEASE CORRECT.
  
 5) ON SHEET A-1 THE DOOR AND WINDOW NOTES APPEAR TO
 INDICATE THE REPLACEMENT OF WINDOWS AND DOORS. PLEASE
 SPECIFY WHICH WINDOWS AND DOORS WILL BE REPLACED.
 SUBMIT 2 COPIES OF PRODUCT APPROVALS, AS REQUIRED BY
 FAC RULE 9B-72, FOR THE WINDOWS AND DOORS THAT ARE
 BEING REPLACED. IF NONE ARE TO BE REPLACED PLEASE
 CLARIFY.
  
 6) ENGINEERED SHOP DRAWINGS AND CALCULATIONS FROM THE
 SPECIALTY CONTRACTOR WILL BE REQUIRED FOR THE HELICAL
 PIERS USED TO REINFORCE THE EXISTING FOUNDATION AT THE
 STEEL COLUMN LOCATIONS.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2009-07-24 Cont ID  
Sent By btrobaug Date 2009-07-24 Time 11:21 Rev Time 0.00
Received By btrobaug Date 2009-07-24 Time 10:51 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2009-06-12 Cont ID  
Sent By rmcdouga Date 2009-06-12 Time 09:53 Rev Time 0.00
Received By rmcdouga Date 2009-06-12 Time 09:53 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2009-05-28 Cont ID  
Sent By btrobaug Date 2009-05-28 Time 09:26 Rev Time 0.00
Received By btrobaug Date 2009-05-28 Time 08:30 Sent To I
Notes
2009-05-28 08:44:06 
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2007 FLORIDA RESIDENTIAL BUILDING CODE, 2009
 REVISIONS, 2005 NEC, 2004 FBC AS AMENDED, CHAPTER 1.AND
 FOUND NONCOMPLIANT WITH THE FOLLOWING:
  
 1} KITCHEN RECEPTACLE SPACING MUST COMPLY WITH
 210.52(A), 210.52(C), AND 210.8(A)(6) GFI.
  
 2} 210.52(C)(1) WALL COUNTER SPACES A RECEPTACLE OUTLET
 SHALL BE INSTALLED AT EACH WALL COUNTER SPACE THAT IS
 300 MM (12 IN.) OR WIDER. RECEPTACLE OUTLETS SHALL BE
 INSTALLED SO THAT NO POINT ALONG THE WALL LINE IS MORE
 THAN 600 MM (24 IN.) MEASURED HORIZONTALLY FROM A
 RECEPTACLE OUTLET IN THAT SPACE.
  
 3} 210.52(C) (2) ISLAND COUNTER SPACES AT LEAST ONE
 RECEPTACLE SHALL BE INSTALLED AT EACH ISLAND COUNTER
 SPACE WITH A LONG DIMENSION OF 600 MM (24 IN.) OR
 GREATER AND A SHORT DIMENSION OF 300 MM (12 IN.) OR
 GREATER. WHERE A RANGETOP OR SINK IS INSTALLED IN AN
 ISLAND COUNTER AND THE WIDTH OF THE COUNTER BEHIND THE
 RANGETOP OR SINK IS LESS THAN 300 MM (12 IN.), THE
 RANGETOP OR SINK IS CONSIDERED TO DIVIDE THE ISLAND
 INTO TWO SEPARATE COUNTERTOP SPACES AS DEFINED IN
 210.52(C)(4).
  
 4} BATH CIRCUIT REQUIRED TO HAVE A 20 AMP RECEPTACLE
 PER 210.11(C) (3), LOCATED PER 210.52(D), AND BE GFI
 PROTECTED PER 210.8(A) (1).
  
 5} 106.1 SUBMITTAL DOCUMENTS. CONSTRUCTION DOCUMENTS,
 SPECIAL INSPECTION AND STRUCTURAL OBSERVATION PROGRAMS,
 AND OTHER DATA SHALL BE SUBMITTED IN TWO OR MORE SETS
 WITH EACH APPLICATION FOR A PERMIT. ONLY ONE SET WAS
 SUBMITTED FOR REVIEW.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2009-07-22 Cont ID  
Sent By lmartine Date 2009-07-22 Time 15:44 Rev Time 0.00
Received By lmartine Date 2009-07-22 Time 15:44 Sent To  
Notes
2009-07-22 15:44:58TO MCDOUGLE

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-05-28 Cont ID  
Sent By btrobaug Date 2009-05-28 Time 09:27 Rev Time 0.00
Received By btrobaug Date 2009-05-19 Time 13:35 Sent To PC
Notes
2009-05-20 13:41:55R-3

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2009-06-12 Cont ID  
Sent By rmcdouga Date 2009-06-12 Time 08:47 Rev Time 0.00
Received By rmcdouga Date 2009-06-12 Time 08:47 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2009-05-27 Cont ID  
Sent By rmcdouga Date 2009-05-27 Time 15:21 Rev Time 0.00
Received By rmcdouga Date 2009-05-27 Time 15:21 Sent To E
Notes
2009-05-27 16:29:472007 FBC
 LEVEL 2 ALTERATION
  
 DENIED BY MECHANICAL
  
 1) TWO SETS OF PLANS ARE REQUIRED TO BE SUBMITTED FOR
 PERMIT. FBC 106.1* CITY AMENDMENTS.
  
 2) UPDATE PLANS TO 2007 FBC, WHICH WENT INTO EFFECT ON
 MARCH 1, 2009.
  
 3) SUBMIT MANUFACTURER'S SPECIFICATIONS, LISTING AND
 DUCTING REQUIREMENTS FOR THE UNDER FLOOR VENTED
 COOKTOP. FBC R M1503.3
  
 4) CLEARLY INDICATE THE SCOPE OF MECHANICAL WORK ON THE
 PLANS.
  
 5) PROVIDE PLANS SHOWING THE LOCATION OF EXISTING
 EQUIPMENT AND DUCTS AND SPECIFY THE NEW LOCATIONS OF
 THE EQUIPMENT AND DUCT WORK.
  
 6) IF INSTALLING NEW SYSTEM SHOW COMPLIANCE WITH 2007
 FBC R MECHANICAL. SUBMIT 2 COPIES OF MECHANICAL PLANS,
 MANUAL J CALCULATIONS, ETC.
  
 7) INDICATE THE CFM CAPACITY OF THE NEW BATHROOM VENT.
 FBC M1507.3
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop P PLUMBING
Rev No 2 Status P Date 2009-06-12 Cont ID  
Sent By rmcdouga Date 2009-06-12 Time 08:46 Rev Time 0.00
Received By rmcdouga Date 2009-06-12 Time 08:46 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2009-05-22 Cont ID  
Sent By kstevens Date 2009-05-22 Time 14:50 Rev Time 0.00
Received By kstevens Date 2009-05-22 Time 14:50 Sent To  
Notes
2009-05-22 15:29:59DENIED
 REFERENCE:
 FBC-2007 W/2009 SUPPLEMENTS
 FBC-2007 RESIDENTIAL
 FBC-2007 CHAPTER 1
  
 1. A MINIMUM 2 SETS OF PLANS ARE REQUIRED FOR REVIEW.
 SECTION 106.1. ONLY ONE SET OF PLANS WAS SUBMITTED.
  
 2. ALL PLANS SUBMITED WITH APPLICATIONS FOR PERMIT ON
 OR AFTER MARCH 1, 2009 SHALL BE DESIGNED UNDER THE
 FBC-2007 W/2009 SUBMITTALS. SHT A-1 INDICATES FBC-2004
 W/2006 REVISIONS. PLEASE DESIGN PLANS UNDER CURRENT
 CODE CYCLE. SECTION 106.1.1.
  
 3. SHT A-2 PLUMBING NOTES NUMBER ONE REFERENCES THE
 STANDARD PLUMBING CODE. PLEASE CHANGE REFERENCE TO
 CURRENT CODE CYCLE, FBC-2007 W/2009 SUPPLEMENTS.
 SECTION 106.1.1.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]
  