Plan Review Stops For Permit 09050385 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2009-09-09 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-09-09 |
Time |
13:39 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-09-09 |
Time |
13:39 |
Sent To |
|
|
Notes |
2009-09-09 13:43:35 | REVISIONS FOR REPLACING DOOR AND AND WINDOW ARE OK. | | ALSO REVISION FOR SC3 BASE PLATE AND FASTENING | | CLARIFICATION LETTERS ARE OK. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2009-08-17 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-08-17 |
Time |
10:38 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-08-17 |
Time |
10:38 |
Sent To |
|
|
Notes |
2009-08-17 10:39:54 | SUBMITTED ENGINEERED SHOP DRAWINGS FOR HELICAL PIER | | INSTALLATION AS REQUIRED BY PROVISO. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2009-06-12 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-06-12 |
Time |
08:42 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-06-12 |
Time |
08:42 |
Sent To |
|
|
Notes |
2009-06-12 08:46:03 | BUILDING PROVISO | | | | 1) PRIOR TO INSTALLATION SUBMIT TWO SETS OF ENGINEERED | | SHOP DRAWINGS AND CALCULATIONS FROM THE SPECIALTY | | CONTRACTOR FOR THE HELICAL PIERS THAT WILL BE | | INSTALLED. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2009-05-27 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-05-27 |
Time |
13:24 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-05-27 |
Time |
13:24 |
Sent To |
|
|
Notes |
2009-05-27 15:06:55 | 2007 FBC | | LEVEL 2 ALTERATION | | | | DENIED BY BUILDING | | | | 1) A MINIMUM OF TWO SETS OF PLANS ARE REQUIRED TO BE | | SUBMITTED FOR PERMIT. FBC 106.1* CITY AMENDMENTS. | | | | 2) THE WRONG EDITION OF FBC IS SPECIFIED. THIS PROJECT | | IS UNDER THE 2007 FBC. PLEASE CORRECT. | | | | 3) SPECIFY THE LEVEL OF ALTERATION ON THE PLANS. FBC | | EXISTING BUILDING SECTION 401.4 | | | | 4) ON SHEET A-2 STEEL COLUMN 2 IS MISLABELED AS S.C. 1 | | ON THE FOUNDATION PLAN. PLEASE CORRECT. | | | | 5) ON SHEET A-1 THE DOOR AND WINDOW NOTES APPEAR TO | | INDICATE THE REPLACEMENT OF WINDOWS AND DOORS. PLEASE | | SPECIFY WHICH WINDOWS AND DOORS WILL BE REPLACED. | | SUBMIT 2 COPIES OF PRODUCT APPROVALS, AS REQUIRED BY | | FAC RULE 9B-72, FOR THE WINDOWS AND DOORS THAT ARE | | BEING REPLACED. IF NONE ARE TO BE REPLACED PLEASE | | CLARIFY. | | | | 6) ENGINEERED SHOP DRAWINGS AND CALCULATIONS FROM THE | | SPECIALTY CONTRACTOR WILL BE REQUIRED FOR THE HELICAL | | PIERS USED TO REINFORCE THE EXISTING FOUNDATION AT THE | | STEEL COLUMN LOCATIONS. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2009-07-24 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2009-07-24 |
Time |
11:21 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2009-07-24 |
Time |
10:51 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2009-06-12 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-06-12 |
Time |
09:53 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-06-12 |
Time |
09:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2009-05-28 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2009-05-28 |
Time |
09:26 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2009-05-28 |
Time |
08:30 |
Sent To |
I |
|
Notes |
2009-05-28 08:44:06 | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | THE 2007 FLORIDA RESIDENTIAL BUILDING CODE, 2009 | | REVISIONS, 2005 NEC, 2004 FBC AS AMENDED, CHAPTER 1.AND | | FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | 1} KITCHEN RECEPTACLE SPACING MUST COMPLY WITH | | 210.52(A), 210.52(C), AND 210.8(A)(6) GFI. | | | | 2} 210.52(C)(1) WALL COUNTER SPACES A RECEPTACLE OUTLET | | SHALL BE INSTALLED AT EACH WALL COUNTER SPACE THAT IS | | 300 MM (12 IN.) OR WIDER. RECEPTACLE OUTLETS SHALL BE | | INSTALLED SO THAT NO POINT ALONG THE WALL LINE IS MORE | | THAN 600 MM (24 IN.) MEASURED HORIZONTALLY FROM A | | RECEPTACLE OUTLET IN THAT SPACE. | | | | 3} 210.52(C) (2) ISLAND COUNTER SPACES AT LEAST ONE | | RECEPTACLE SHALL BE INSTALLED AT EACH ISLAND COUNTER | | SPACE WITH A LONG DIMENSION OF 600 MM (24 IN.) OR | | GREATER AND A SHORT DIMENSION OF 300 MM (12 IN.) OR | | GREATER. WHERE A RANGETOP OR SINK IS INSTALLED IN AN | | ISLAND COUNTER AND THE WIDTH OF THE COUNTER BEHIND THE | | RANGETOP OR SINK IS LESS THAN 300 MM (12 IN.), THE | | RANGETOP OR SINK IS CONSIDERED TO DIVIDE THE ISLAND | | INTO TWO SEPARATE COUNTERTOP SPACES AS DEFINED IN | | 210.52(C)(4). | | | | 4} BATH CIRCUIT REQUIRED TO HAVE A 20 AMP RECEPTACLE | | PER 210.11(C) (3), LOCATED PER 210.52(D), AND BE GFI | | PROTECTED PER 210.8(A) (1). | | | | 5} 106.1 SUBMITTAL DOCUMENTS. CONSTRUCTION DOCUMENTS, | | SPECIAL INSPECTION AND STRUCTURAL OBSERVATION PROGRAMS, | | AND OTHER DATA SHALL BE SUBMITTED IN TWO OR MORE SETS | | WITH EACH APPLICATION FOR A PERMIT. ONLY ONE SET WAS | | SUBMITTED FOR REVIEW. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2009-07-22 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2009-07-22 |
Time |
15:44 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2009-07-22 |
Time |
15:44 |
Sent To |
|
|
Notes |
2009-07-22 15:44:58 | TO MCDOUGLE |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2009-05-28 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2009-05-28 |
Time |
09:27 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2009-05-19 |
Time |
13:35 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2009-06-12 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-06-12 |
Time |
08:47 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-06-12 |
Time |
08:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2009-05-27 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-05-27 |
Time |
15:21 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-05-27 |
Time |
15:21 |
Sent To |
E |
|
Notes |
2009-05-27 16:29:47 | 2007 FBC | | LEVEL 2 ALTERATION | | | | DENIED BY MECHANICAL | | | | 1) TWO SETS OF PLANS ARE REQUIRED TO BE SUBMITTED FOR | | PERMIT. FBC 106.1* CITY AMENDMENTS. | | | | 2) UPDATE PLANS TO 2007 FBC, WHICH WENT INTO EFFECT ON | | MARCH 1, 2009. | | | | 3) SUBMIT MANUFACTURER'S SPECIFICATIONS, LISTING AND | | DUCTING REQUIREMENTS FOR THE UNDER FLOOR VENTED | | COOKTOP. FBC R M1503.3 | | | | 4) CLEARLY INDICATE THE SCOPE OF MECHANICAL WORK ON THE | | PLANS. | | | | 5) PROVIDE PLANS SHOWING THE LOCATION OF EXISTING | | EQUIPMENT AND DUCTS AND SPECIFY THE NEW LOCATIONS OF | | THE EQUIPMENT AND DUCT WORK. | | | | 6) IF INSTALLING NEW SYSTEM SHOW COMPLIANCE WITH 2007 | | FBC R MECHANICAL. SUBMIT 2 COPIES OF MECHANICAL PLANS, | | MANUAL J CALCULATIONS, ETC. | | | | 7) INDICATE THE CFM CAPACITY OF THE NEW BATHROOM VENT. | | FBC M1507.3 | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2009-06-12 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-06-12 |
Time |
08:46 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-06-12 |
Time |
08:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2009-05-22 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2009-05-22 |
Time |
14:50 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2009-05-22 |
Time |
14:50 |
Sent To |
|
|
Notes |
2009-05-22 15:29:59 | DENIED | | REFERENCE: | | FBC-2007 W/2009 SUPPLEMENTS | | FBC-2007 RESIDENTIAL | | FBC-2007 CHAPTER 1 | | | | 1. A MINIMUM 2 SETS OF PLANS ARE REQUIRED FOR REVIEW. | | SECTION 106.1. ONLY ONE SET OF PLANS WAS SUBMITTED. | | | | 2. ALL PLANS SUBMITED WITH APPLICATIONS FOR PERMIT ON | | OR AFTER MARCH 1, 2009 SHALL BE DESIGNED UNDER THE | | FBC-2007 W/2009 SUBMITTALS. SHT A-1 INDICATES FBC-2004 | | W/2006 REVISIONS. PLEASE DESIGN PLANS UNDER CURRENT | | CODE CYCLE. SECTION 106.1.1. | | | | 3. SHT A-2 PLUMBING NOTES NUMBER ONE REFERENCES THE | | STANDARD PLUMBING CODE. PLEASE CHANGE REFERENCE TO | | CURRENT CODE CYCLE, FBC-2007 W/2009 SUPPLEMENTS. | | SECTION 106.1.1. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | ONE SET OF THEM LOOSELY ON TOP OF THE | | COLLATED PLANS TO BE REVIEWED. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | |
|
|