Plan Review Stops For Permit 09050371 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2009-09-24 |
|
|
Cont ID |
|
Sent By |
dwise |
Date |
2009-09-24 |
Time |
13:02 |
Rev Time |
0.00 |
Received By |
dwise |
Date |
2009-09-24 |
Time |
13:01 |
Sent To |
|
|
Notes |
2009-09-24 13:02:26 | STOREFRONT DOOR AND WINDOW SCHEDULES AND PRODUCT | | APPROVALS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2009-07-08 |
|
|
Cont ID |
|
Sent By |
dwise |
Date |
2009-07-08 |
Time |
21:55 |
Rev Time |
0.00 |
Received By |
dwise |
Date |
2009-07-08 |
Time |
21:55 |
Sent To |
FIRE |
|
Notes |
2009-07-08 21:57:14 | APPROVED WITH PROVISOS: | | 1. SUBMIT PRODUCT APPROVALS FOR IMPACT RESISTANT | | STOREFRONT, DOORS, AND EXTERIOR COMPONENTS AND CLADDING | | WHICH HAVE BEEN "ACCEPTED" FOR USE BY THE DESIGN | | PROFESSIONAL FOR REVIEW AND ACCEPTANCE BY THE CITY | | PRIOR TO INSTALLATION IN THE BUILDING. | | 2. SUBMIT REVISED X-RAY SHIELDING SPECIFICATIONS WHICH | | BEAR THE STAMP OF APPROVAL FROM THE DESIGN PROFESSIONAL | | RESPONSIBLE FOR THE PROJECT FOR REVIEW PRIOR TO | | INSTALLATION IN THE BUILDING. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2009-05-28 |
|
|
Cont ID |
|
Sent By |
dwise |
Date |
2009-05-28 |
Time |
20:30 |
Rev Time |
0.00 |
Received By |
dwise |
Date |
2009-05-28 |
Time |
18:00 |
Sent To |
|
|
Notes |
2009-05-28 20:28:13 | 1.SHEET A-1. PLEASE PROVIDE AN EXISTING FLOOR OR DEMO | | PLAN IN ORDER TO CLARIFY THE EXTERIOR ENVELOPE OPENINGS | | THAT ARE BEING REMOVED AND CREATED AS A RESULT OF THIS | | PROJECT. | | 2.SHEET A-1. PLEASE PROVIDE ANY AND ALL REVISED | | EXTERIOR ELEVATIONS. | | 3. SHEET A-1. PLEASE CLARIFY NOTE RELATED TO "IMPACT" | | FILM IS APPLICABLE ONLY TO EXISTING EXTERIOR GLAZING. | | IT SHOULD ALSO BE NOTED THAT THERE IS NO FILM CURRENTLY | | IN EXISTENCE WHICH SATISFIES THE APPLICABLE CODE | | REQUIREMENTS FOR GLAZING PROTECTION IN THE WINDBORNE | | DEBRIS REGION. | | 4. SHEET A-1 PLEASE PROVIDE DESIGN PRESSURES FOR ALL | | EXTERIOR COMPONENTS AND CLADDING (I.E., DOORS AND | | WINDOWS) THAT ARE BEING PROPOSED AS A RESULT OF THIS | | PROJECT. | | 5. INFORMATIONAL ONLY: THE APPLICANT WILL BE REQUIRED | | TO PROVIDE PRODUCT APPROVALS FOR VARIOUS COMPONENTS OF | | THIS PROJECT FOR REVIEW AND APPROVAL BY THE | | CONSTRUCTION SERVICES DEPARTMENT BEFORE THEY ARE | | INSTALLED AT THE SITE. THESE COMPONENTS INCLUDE (BUT | | ARE NOT LIMITED TO) DOOR AND STORE FRONT PRODUCT | | APPROVALS, X-RAY EQUIPMENT, X-RAY SHIELDING, AND | | PERMANENTLY WIRED EQUIPMENT. ALL OF THESE SUBMITTALS | | MUST BEAR THE APPROVAL OF THE APPLICABLE DESIGN | | PROFESSIONAL AT THE TIME OF SUBMITTAL. | | 6. INFORMATIONAL ONLY: SEPERATE APPLICATION, REVIEW, | | ACCEPTANCE AND PERMITTING SHALL BE REQUIRED FOR WORK | | RELATED TO FIRE ALARMS, FIRE SPRINKLERS, GREASE TRAPS, | | GAS, GENERATORS, FENCES, SITE LIGHTING, SITE | | LANDSCAPING, AND SITE IRRIGATION (IF ANY) WHICH MAY BE | | PROPOSED IN CONJUNCTION WITH THIS PROJECT. | | 7. INFORMATIONAL ONLY: IT APPEARS THAT THE APPLICANT | | PROPOSES TO PLACE A GENERATOR AND SLAB OVER TWO | | ABANDONED GREASE TRAPS. THE EXISTING GREASE TRAPS SHALL | | BE ABANDONED PURSUANT TO STATE DEPARTMENT OF HEALTH | | REGULATIONS, AND MAY NOT BE DEEMED SUITABLE AS A | | FOUNDATION FOR THE GENERATOR SLAB BY THE CONSTRUCTION | | SERVICES DEPARTMENT. | | | | PLEASE FEEL FREE TO CONTACT ME DURING NORMAL BUSINESS | | HOURS IF YOU HAVE ANY QUESTIONS ABOUT THIS REVIEW. I | | MAY BE REACHED AT 561-805-6650 OR BY EMAIL AT | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2009-07-08 |
|
|
Cont ID |
|
Sent By |
dwise |
Date |
2009-07-08 |
Time |
21:32 |
Rev Time |
0.00 |
Received By |
dwise |
Date |
2009-07-08 |
Time |
21:32 |
Sent To |
|
|
Notes |
2009-07-08 21:35:31 | APPROVED WITH PROVISO: PURSANT TO PRIOR REQUEST, IT | | STILL APPEARS THAT INADEQUATE ESSENTIAL ELECTRICAL | | SYSTEM TASK LIGHTING HAS BEEN PROVIDED IN THE EXAM | | ROOMS TO PROVIDE FOR THE ORDERLY CESSATION OF | | PROCEDURES IN THE EVENT OF A POWER FAILURE AT THE | | FACILITY. ALTHOUGH SOME EMERGENCY TASK LIGHTING HAS | | BEEN PROVIDED, A SIGNIFICANT NUMBER OF EXAM ROOMS HAVE | | BEEN OMMITED. PLEASE PROVIDE A REVISION WHICH SATISFIES | | THE REQUIREMENTS OF NEC SECTION 517.33. NOTE: BATTERY | | BACKUP EMERGENCY LIGHTS MAY BE UTILIZED. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2009-05-28 |
|
|
Cont ID |
|
Sent By |
dwise |
Date |
2009-05-28 |
Time |
21:07 |
Rev Time |
0.00 |
Received By |
dwise |
Date |
2009-05-28 |
Time |
21:07 |
Sent To |
FIRE |
|
Notes |
2009-05-28 21:12:10 | 1. ESSENTIAL ELECTRICAL SYSTEM TASK LIGHTING DOES NOT | | APPEAR TO BE INSTALLED IN ALL EXAM AND PROCEDURE AREAS | | PURSUANT TO THE REQUIREMENTS OF 517.33. | | 2. THE X RAY DISCONNECTING MEANS APPEARS TO BE LOCATED | | IN A DIFFERENT ROOM THAN THE X RAY CONTROL PANEL AND IS | | THEREFORE NOT READILY ACCESSIBLE PURSUANT TO 517.72 (B) | | 3. SHEET E-1 NOTE 8(B) NON-METALLIC CONDUIT MAY NOT BE | | RUN UNDERGROUND TO SERVE ANY PATIENT CARE AREAS | | PURSUANT TO 517.13.(A) AND (B). | | 4. ALL RECEPTACLES IN PATIENT CARE AREAS SHALL BE | | DESIGNATED AS HOSPITAL GRADE PURSUANT TO 517.18(B), | | 5. SHEET E-3.1. NOTE D. PLEASE ENSURE THAT RECEPTACLES | | IDENTIFIED AS BEING NECESSARY FOR THE ESSENTIAL | | ELECTRICAL SYSTEM MANDATED FOR THIS FACILITY PURSUANT | | TO 517.25 ARE PROVIDED IN EACH AREA SO DESIGNATED. IT | | APPEARS THAT ONLY CERTAIN EXAMINATION AND PROCEDURE | | ROOMS ARE APPROPRIATELY CIRCUITED. PLEASE CLARIFY. | | 6. INFORMATIONAL ONLY: SEPARATE APPLICATIONS AND | | PERMITS ARE REQUIRED FOR THE PROPOSED GENERATOR AND | | FIRE ALARM SYSTEM. | | PLEASE FEEL FREE TO CONTACT ME DURING NORMAL BUSINESS | | HOURS IF YOU HAVE ANY QUESTIONS ABOUT THIS REVIEW. I | | MAY BE REACHED AT 561-805-6650 OR BY EMAIL AT | | [email protected] |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2009-07-13 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2009-07-13 |
Time |
14:50 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2009-07-13 |
Time |
14:08 |
Sent To |
|
|
Notes |
2009-07-13 14:50:28 | *****APPROVED***** | | | | THE COMMENTS FORMO THE PREVIOUS FIRE PLAN REVIEW HAVE | | BEEN ADDRESSED; PLAN SHEETS LS-1, A-1, A-3, A-4, E-2.1, | | E-2.2, E-4.1, E-4.2, E-8, FS-1, FS-2.1, FS-2.2, AND | | FS-3 WERE STAMPED, INITIALED, AND DATED. | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2009-06-02 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2009-06-02 |
Time |
16:13 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2009-06-02 |
Time |
15:13 |
Sent To |
|
|
Notes |
2009-06-02 16:13:20 | *****DENIED***** | | | | 1. PROVIDE A POINT OF COMPASS FOR THE FLOOR PLAN SO AS | | IT RELATES TO PALM BEACH LAKES BOULEVARD. | | | | 2.. ON SHEET A-4, INDICATE FIRE-RATED DOORS. BE ADVISED | | THAT FIRE-RATED DOORS AND ASSEMBLIES SHALL COMPLY WITH | | NFPA 80 - 1999 EDITION. | | | | 3. ON SHEET E-8, FIRE ALARM NOTES, AMEND NOTE #7 TO | | INDICATE THAT: DUCT SMOKE DETECTORS SHALL INITIATE A | | GENERAL FIRE ALARM. | | | | 4. ON SHEET FS-1, UNDER FIRE SPRINKLER NOTES | | -COMPLIANCE, CODE EDITIONS AS FOLLOWS: NFPA 13 - 2002, | | NFPA 13R - 2002, NFPA 14 - 2003, NFPA 20 - 2003, AND | | NFPA 25 - 2002 SHALL BE REFERENCED. | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | LETTER INDICATING WHERE EASCH ITEM WAS ADDRESSED | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2009-11-19 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2009-11-19 |
Time |
08:59 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2009-11-19 |
Time |
08:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2009-11-02 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2009-10-29 |
Time |
16:07 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2009-10-29 |
Time |
16:07 |
Sent To |
|
|
Notes |
2009-11-02 16:08:28 | IN MECHANICAL BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2009-10-22 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2009-10-22 |
Time |
10:46 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2009-10-22 |
Time |
10:46 |
Sent To |
|
|
Notes |
2009-10-22 10:47:13 | SENT TO FIRE. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2009-07-24 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-07-24 |
Time |
08:15 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-07-24 |
Time |
08:15 |
Sent To |
P |
|
Notes |
2009-11-19 09:09:53 | SENT TO C-17 | 2009-07-24 08:15:56 | PLANS TO DW OFFICE. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2009-06-02 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2009-06-02 |
Time |
15:13 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2009-05-19 |
Time |
10:42 |
Sent To |
|
|
Notes |
2009-05-19 10:43:05 | TO COMMERCIAL BOX # C2. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2009-11-10 |
Time |
15:29 |
Sent To |
|
|
Notes |
2009-11-10 15:33:10 | REVISED M-2.1, M2.2, M5, M7 DELTA 2 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2009-07-08 |
|
|
Cont ID |
|
Sent By |
dwise |
Date |
2009-07-08 |
Time |
21:14 |
Rev Time |
0.00 |
Received By |
dwise |
Date |
2009-07-08 |
Time |
21:14 |
Sent To |
|
|
Notes |
2009-07-08 21:17:08 | APPROVED WITH PROVISO: PROVIDE A PRODUCT APPROVAL FOR | | THE ROOFTOP EQUIPMENT STANDS AS SPECIFIED BY THE DESIGN | | PROFESSIONAL TO THE FIELD INSPECTOR AT THE TIME OF | | INSPECTION FOR INCLUSION IN THE CITY FILE. NO DEVIATION | | FROM THE SPECIFIED PRODUCT APPROVAL MAY BE ALLOWED WITH | | EXPRESS CONSENT OF BOTH THE DESIGN PROFESSIONAL AND THE | | CITY. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2009-05-28 |
|
|
Cont ID |
|
Sent By |
dwise |
Date |
2009-05-28 |
Time |
17:43 |
Rev Time |
0.00 |
Received By |
dwise |
Date |
2009-05-28 |
Time |
17:43 |
Sent To |
|
|
Notes |
2009-05-28 17:44:49 | 1. SHEET M-3. KEY NOTE #4 CALLS FOR SCREEN AT DRYER | | EXHAUST OUTLET. SCREEN SHALL NOT BE INSTALLED AT DRYER | | EXHAUST DUCT TERMINATION IN ACCORDANCE WITH FBC-M | | 504.4. | | 2. SHEET M-5. OUTSIDE AIR CALCULATIONS REFERENCE ASHRAE | | 62.1-2007. THIS IS NOT THE CORRECT REFERENCE STANDARD. | | PLEASE CONFIRM VENTILATION DESIGN IS IN COMPLIANCE WITH | | ASHRAE 62.1-2004 IN ACCORDANCE WITH FBC-M 403.4 AND | | FBC-M CHAPTER 15. | | 3. SHEET M-7. PROVIDE AUXILIARY DRAIN PROTECTION. ON | | DOWN-FLOW UNITS AND ALL OTHER COILS THAT DO NOT HAVE A | | SECONDARY DRAIN AND DO NOT HAVE A MEANS TO INSTALL AN | | AUXILIARY DRAIN PAN, A WATER-LEVEL MONITORING DEVICE | | SHALL BE INSTALLED INSIDE THE PRIMARY DRAIN PAN IN | | ACCORDANCE WITH FBC-M 307.2.3.1. | | 4. CONDENSING UNIT IS SHOWN ON A PRE-ENGINEERED A/C | | STAND. THIS IS DEFINED AS A STRUCTURAL COMPONENT IN | | ACCORDANCE WIT FAC RULE 9B-72. PROVIDE PRODUCT APPROVAL | | FOR THE STAND TO BE USED WITH INSTALLATION | | INSTRUCTIONS. | | 5. SHEET M-7. RTU NOTE #7 CALLS FOR CONDENSATE DRAINS | | TO BE ROUTED TO THE NEAREST FLOOR DRAIN. CONDENSATE | | SHALL NOT DISCHARGE INTO THE SANITARY SEWER SYSTEM IN | | ACCORDANCE WITH CITY ORDINANCE. CONDENSATE PIPING SHALL | | BE DISCHARGED AS SHOWN ON SHEET P-4 IN ACCORDANCE WITH | | FBC-M 307.2.1. | | 6. SHEET M-7. EQUIPMENT AND APPLIANCES THAT ARE EXPOSED | | TO WIND SHALL BE DESIGNED AND INSTALLED TO RESIST WIND | | PRESSURES AS DETERMINED IN ACCORDANCE WITH THE FLORIDA | | BUILDING CODE, BUILDING. PROVIDE MANUFACTURER???S DATA | | OR OTHER SUCH SUPPORTING DOCUMENTATION SHOWING RTUS, | | CONDENSERS AND ROOF CAPS ARE DESIGNED FOR WIND | | RESISTANCE IN ACCORDANCE WITH FBC-M 301.12. | | | | PLEASE FEEL FREE TO CONTACT ME DURING NORMAL BUSINESS | | HOURS IF YOU HAVE ANY QUESTIONS ABOUT THIS REVIEW. I | | MAY BE REACHED AT 561-805-6650 OR BY EMAIL AT | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2010-01-13 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2010-01-13 |
Time |
12:27 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2010-01-13 |
Time |
12:17 |
Sent To |
|
|
Notes |
2010-01-13 12:27:59 | REVISION OK |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2009-08-11 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2009-08-11 |
Time |
10:44 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2009-08-11 |
Time |
09:53 |
Sent To |
|
|
Notes |
2009-08-11 10:45:44 | GAS PERMIT REQUIRED |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2009-07-08 |
|
|
Cont ID |
|
Sent By |
dwise |
Date |
2009-07-08 |
Time |
21:06 |
Rev Time |
0.00 |
Received By |
dwise |
Date |
2009-07-08 |
Time |
21:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2009-05-28 |
|
|
Cont ID |
|
Sent By |
dwise |
Date |
2009-05-28 |
Time |
17:42 |
Rev Time |
0.00 |
Received By |
dwise |
Date |
2009-05-28 |
Time |
17:39 |
Sent To |
|
|
Notes |
2009-05-28 17:43:18 | 1. SHEET LS-1:YOU MAY NOT SUBSTITUTE WATER COOLERS OR | | BOTTLED WATER DISPENSERS FOR MORE THAN 50% OF THE | | REQUIRED DRINKING FOUNTAINS. 410.1 APPROVAL. DRINKING | | FOUNTAINS SHALL CONFORM TO ASME A112.19.1M, ASME | | A112.19.2M OR ASME A112.19.9M AND WATER COOLERS SHALL | | CONFORM TO ARI 1010. DRINKING FOUNTAINS AND WATER | | COOLERS SHALL CONFORM TO NSF 61, SECTION 9. WHERE WATER | | IS SERVED IN RESTAURANTS, DRINKING FOUNTAINS SHALL NOT | | BE REQUIRED. IN OTHER OCCUPANCIES, WHERE DRINKING | | FOUNTAINS ARE REQUIRED, WATER COOLERS OR BOTTLED WATER | | DISPENSERS SHALL BE PERMITTED TO BE SUBSTITUTED FOR NOT | | MORE THAN 50 PERCENT OF THE REQUIRED DRINKING | | FOUNTAINS. | | | | 2. IN ADDITION TO THE REQUIREMENTS LISTED ABOVE IN ITEM | | 1 BOTH OF THESE REQUIRED FACILITIES MUST COMPLY WITH | | SECTION 11-4.15: | | 11-4.15.1 MINIMUM NUMBER. DRINKING FOUNTAINS OR WATER | | COOLERS REQUIRED TO BE ACCESSIBLE BY SECTION 11-4.1 | | SHALL COMPLY WITH SECTION 11-4.15. | | 11-4.15.2 SPOUT HEIGHT. SPOUTS SHALL BE NO HIGHER THAN | | 36 INCHES (915 MM), MEASURED FROM THE FLOOR OR GROUND | | SURFACES TO THE SPOUT OUTLET [SEE FIGURE 27(A)]. | | 11-4.15.3 SPOUT LOCATION. THE SPOUTS OF DRINKING | | FOUNTAINS AND WATER COOLERS SHALL BE AT THE FRONT OF | | THE UNIT AND SHALL DIRECT THE WATER FLOW IN A | | TRAJECTORY THAT IS PARALLEL OR NEARLY PARALLEL TO THE | | FRONT OF THE UNIT. THE SPOUT SHALL PROVIDE A FLOW OF | | WATER AT LEAST 4 INCHES (102 MM) HIGH SO AS TO ALLOW | | THE INSERTION OF A CUP OR GLASS UNDER THE FLOW OF | | WATER. ON AN ACCESSIBLE DRINKING FOUNTAIN WITH A ROUND | | OR OVAL BOWL, THE SPOUT MUST BE POSITIONED SO THE FLOW | | OF WATER IS WITHIN 3 INCHES (76 MM) OF THE FRONT EDGE | | OF THE FOUNTAIN. | | 11-4.15.4 CONTROLS. CONTROLS SHALL COMPLY WITH SECTION | | 11-4.27.4. UNIT CONTROLS SHALL BE FRONT MOUNTED OR SIDE | | MOUNTED NEAR THE FRONT EDGE. | | 11-4.15.5 CLEARANCES. | | (1) WALL- AND POST-MOUNTED CANTILEVERED UNITS SHALL | | HAVE A CLEAR KNEE SPACE BETWEEN THE BOTTOM OF THE APRON | | AND THE FLOOR OR GROUND AT LEAST 27 INCHES (685 MM) | | HIGH, 30 INCHES (760 MM) WIDE, AND 17 INCHES TO 19 | | INCHES (430 MM TO 485 MM) DEEP [SEE FIGURE 27(A) AND | | FIGURE 27(B)]. SUCH UNITS SHALL ALSO HAVE A MINIMUM | | CLEAR FLOOR SPACE 30 INCHES BY 48 INCHES (760 MM BY | | 1219 MM) TO ALLOW A PERSON IN A WHEELCHAIR TO APPROACH | | THE UNIT FACING FORWARD. | | (2) FREE-STANDING OR BUILT-IN UNITS NOT HAVING A CLEAR | | SPACE UNDER THEM SHALL HAVE A CLEAR FLOOR SPACE AT | | LEAST 30 INCHES BY 48 INCHES (760 MM BY 1219 MM) THAT | | ALLOWS A PERSON IN A WHEELCHAIR TO MAKE A PARALLEL | | APPROACH TO THE UNIT [SEE FIGURE 27(C) AND FIGURE | | 27(D)]. THIS CLEAR FLOOR SPACE SHALL COMPLY WITH | | SECTION 11-4.2.4. | | | | 3. SHEET LS-1 THE REQUIRED NUMBER OF FIXTURES HAS BEEN | | INCORRECTLY STATED IN THE FIXTURE TABULATION. 403.3 | | NUMBER OF OCCUPANTS OF EACH SEX. THE REQUIRED WATER | | CLOSETS, LAVATORIES, AND SHOWERS OR BATHTUBS SHALL BE | | DISTRIBUTED EQUALLY BETWEEN THE SEXES BASED ON THE | | PERCENTAGE OF EACH SEX ANTICIPATED IN THE OCCUPANT | | LOAD. THE OCCUPANT LOAD SHALL BE COMPOSED OF 50 PERCENT | | OF EACH SEX, UNLESS STATISTICAL DATA APPROVED BY THE | | CODE OFFICIAL INDICATE A DIFFERENT DISTRIBUTION OF THE | | SEXES (SEE ALSO SECTION 403.1.1).THE TOTAL NUMBER OF | | OCCUPANTS IS 167. THE OCCUPANT LOAD FOR EACH SEX IS | | THEREFORE 84. UTILIZING TABLE 403.1 THIS REQUIRES: | | WATER CLOSETS 3 MALE, 3 FEMALE; LAVATORIES 3 MALE, 3 | | FEMALE. YOU MAY NOT UNDERSTATE THE REQUIRED NUMBER OF | | FIXTURES EVEN THOUGH YOU HAVE PROPOSED TO CONSTRUCT | | MORE THAN THE MINIMUM REQUIRED. | | | | 4. SHEET LS-1 THERE IS A CITED A CODE REFERENCE WHICH | | DOES NOT EXIST OR DOES NOT APPLY TO THIS PROJECT (403.2 | | 01 FPC EXCEPTION 2), AND CLAIMED AN ALTERNATE EXEMPTION | | (FBC 104.11) TO THE REQUIRED NUMBER OF DRINKING | | FOUNTAINS WHICH DIRECTLY CONTRADICTS SECTION 410.1 OF | | THE PLUMBING CODE. | | | | 5. SHEET A-6 DETAIL 1. A FOLDING DOOR IS SHOWN WHICH | | ENCROACHES ON THE REQUIRED CLEAR FLOOR SPACE FOR THE | | WATER CLOSET IN VIOLATION OF 11-4.22.2(1). ALTHOUGH YOU | | HAVE PROVIDED AN ???EXTRA??? TOILET ROOM IN THE | | FACILITY, YOU HAVE CALLED THIS ONE OUT AS AN | | ???EMPLOYEE RESTROOM???. AS, SUCH IT MUST COMPLY WITH | | THE REFERENCED SECTION. | | | | PLEASE FEEL FREE TO CONTACT ME DURING NORMAL BUSINESS | | HOURS IF YOU HAVE ANY QUESTIONS ABOUT THIS REVIEW. I | | MAY BE REACHED AT 561-805-6650 OR BY EMAIL AT | | [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2009-07-16 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2009-07-16 |
Time |
11:57 |
Rev Time |
0.25 |
Received By |
eschneid |
Date |
2009-07-16 |
Time |
11:57 |
Sent To |
|
|
Notes |
2009-07-16 11:59:53 | PASSED W/PROVISOS | | | | 1) A PERMIT FOR THE LANDSCAPE AND SITE IMPROVEMENTS | | SHALL BE SUBMITTED PRIOR TO THE INTERIOR BUILDING | | FRAMING INSPECTION. | | | | 2) THE LANDSCAPE AND SITE IMPROVEMENTS SHALL BE | | COMPLETED AND A FINAL INSPECTION PASSED PRIOR THE C.O. | | FOR THIS PERMIT. | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2009-07-15 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2009-07-15 |
Time |
14:37 |
Rev Time |
0.25 |
Received By |
eschneid |
Date |
2009-07-15 |
Time |
14:37 |
Sent To |
|
|
Notes |
2009-07-15 14:38:18 | FAILED | | | | COMMENTS FROM THE MAY 28, 2009 REVIEW HAVE NOT BEEN | | ADDRESSED. | | | | 1) THE ZONING AND LAND DEVELOPMENT REGULATIONS REQUIRE | | THAT IF RENOVATIONS TO A BUILDING EXCEED 50% OF THE | | VALUE OF THE BUILDING, THEN THE SITE SHALL BE BROUGHT | | INTO CONFORMITY WITH THE CITY'S LANDSCAPE REGULATIONS. | | | | 2) THE PALM BEACH COUNTY PROPERTY APPRAISER VALUES THE | | BUILDING AT $753,490. THE VALUE OF THIS PERMIT | | ($600,000) PLUS THE VALUE OF THE INTERIOR DEMOLITION | | PERMIT ($15,000) TOTALS $615,000. THEREFORE, THE | | RENOVATIONS EXCEED 50% OF THE VALUE OF THE BUILDING AND | | THE SITE SHALL BE BROUGHT INTO CONFORMITY WITH ARTICLE | | XIV OF THE ZONING AND LAND DEVELOPMENT REGULATIONS. A | | LANDSCAPE PLAN, PREPARED BY A FLORIDA REGISTERED | | LANDSCAPE ARCHITECT, IS REQUIRED AS PART OF THIS | | PERMIT, OR AS PART OF A SEPARATE SITE WORK PERMIT, | | PRIOR TO ZONING APPROVING THE RENOVATION PERMIT. ALL | | REQUIRED LANDSCAPE WORK, TO INCLUDE IRRIGATION, SHALL | | BE COMPLETED PRIOR TO THE CERTIFICATE OF OCCUPANCY IS | | ISSUED FOR THE BUILDING RENOVATIONS INCLUDED AS PART OF | | THIS PERMIT. | | | | 3) NOTE: THE LANDSCAPE REQUIREMENT CITED ABOVE DOES NOT | | APPLY IF A CURRENT CERTIFIED APPRAISAL OF THE BUILDING | | AT 2007 PALM BEACH LAKES BOULEVARD, SHOWING THE VALUE | | IN EXCESS OF $1,230,000, IS PROVIDED AS PART OF THE | | PERMIT RESUBMITTAL. | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2009-05-28 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2009-05-28 |
Time |
13:59 |
Rev Time |
0.75 |
Received By |
eschneid |
Date |
2009-05-28 |
Time |
13:59 |
Sent To |
|
|
Notes |
2009-05-28 15:21:06 | FAILED | | | | THE ZONING AND LAND DEVELOPMENT REGULATIONS REQUIRE | | THAT IF RENOVATIONS TO A BUILDING EXCEED 50% OF THE | | VALUE OF THE BUILDING, THEN THE SITE SHALL BE BROUGHT | | INTO CONFORMITY WITH THE CITY'S LANDSCAPE REGULATIONS. | | | | THE PALM BEACH COUNTY PROPERTY APPRAISER VALUES THE | | BUILDING AT $753,490. THE VALUE OF THIS PERMIT | | ($600,000) PLUS THE VALUE OF THE INTERIOR DEMOLITION | | PERMIT ($15,000) TOTALS $615,000. THEREFORE, THE | | RENOVATIONS EXCEED 50% OF THE VALUE OF THE BUILDING AND | | THE SITE SHALL BE BROUGHT INTO CONFORMITY WITH ARTICLE | | XIV OF THE ZONING AND LAND DEVELOPMENT REGULATIONS. A | | LANDSCAPE PLAN, PREPARED BY A FLORIDA REGISTERED | | LANDSCAPE ARCHITECT, IS REQUIRED AS PART OF THIS | | PERMIT, OR AS PART OF A SEPARATE SITE WORK PERMIT. ALL | | REQUIRED LANDSCAPE WORK, TO INCLUDE IRRIGATION, SHALL | | BE COMPLETED PRIOR TO THE CERTIFICATE OF OCCUPANCY IS | | ISSUED FOR THE BUILDING RENOVATIONS INCLUDED AS PART OF | | THIS PERMIT. | | | | NOTE: THE LANDSCAPE REQUIREMENT CITED ABOVE DOES NOT | | APPLY IF A CURRENT CERTIFIED APPRAISAL OF THE BUILDING | | AT 2007 PALM BEACH LAKES BOULEVARD, SHOWING THE VALUE | | IN EXCESS OF $1,230,000, IS PROVIDED AS PART OF THE | | PERMIT RESUBMITTAL. | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1435. | | |
|
|