Plan Review Details - Permit 09050247
Plan Review Stops For Permit 09050247
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2009-05-15 Cont ID  
Sent By jnguyen Date 2009-05-15 Time 17:36 Rev Time 0.00
Received By jnguyen Date 2009-05-15 Time 15:54 Sent To  
Notes
2009-05-15 16:37:23I CALLED & TALKED TO THE CONTRACTOR, JEFF FISHER. FROM
 MY UNDERSTANDING, HE STATED THAT SUITE # 101 WAS BEING
 CONVERTED TO # 125, WHEREAS # 103 WOULD BE KNOWN AS #
 150. UNDER SECTION 1.3 OF THE CITY'S ADDRESSING POLICY
 STATING, "IT WILL BE THE DEVELOPER'S RESPONSIBILITY TO
 ASSIGN UNIT (DESIGNATORS) ADDRESSES TO ALL UNITS INSIDE
 THE STRUCTURE. THE LIST OF ADDRESSES MUST BE APPROVED
 BY THE MIS SUPPORT SERVICES DEPARTMENT. THE UNIT
 DESIGNATORS SHALL BE NUMERIC & NOT INCLUDE ALPHA
 CHARACTERS." SINCE THE PROPOSED CHANGES FROM # 101 TO
 #125 & # 103 TO #150 DO NOT VIOLATE OUR ADDRESSING
 POLICY, THE DEVELOPER CAN PROCEED WITH MAKING THE
 CHANGES AT HIS/HER DISCRETION. HOWEVER, IT WILL BE
 HIS/HER RESPONSIBILITY TO NOTIFY USPS & THEIR BILLING
 COMPANIES OF THE CHANGING SUITE ADDRESSES. UNDER PCN#
 74434329160010091, I HAVE ADJUSTED SEQUENTIAL UNIT
 RECORD 0003 FROM 2400 CENTREPARK WEST DR # 101 TO #
 125, WHEREAS THERE WAS ALREADY AN EXISTING SEQUENTIAL
 UNIT RECORD 0004 FOR 2400 CENTREPARK WEST DR # 150. I
 ALSO CALLED & LEFT A MESSAGE FOR THE ARCHITECT, ALLEN
 BIRSE TO CALL ME BACK AT HIS CONVENIENCE, AS THE SITE
 PLANS STILL LIST SUITES # 101 & # 103, AND MAY NEED TO
 BE ADJUSTED TO # 125 & # 150. I HAVE RETURNED THE
 FOLDER OF DOCUMENTS BACK TO THE C21 BOX.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2009-09-15 Cont ID  
Sent By jwitmer Date 2009-09-15 Time 08:27 Rev Time 0.50
Received By jwitmer Date 2009-09-15 Time 08:27 Sent To  
Notes
2009-09-15 08:28:22REVISION DATED SEPT 11/2009

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2009-07-15 Cont ID  
Sent By jwitmer Date 2009-07-15 Time 16:33 Rev Time 0.55
Received By jwitmer Date 2009-07-15 Time 16:33 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2009-05-29 Cont ID  
Sent By jwitmer Date 2009-05-29 Time 14:53 Rev Time 0.77
Received By jwitmer Date 2009-05-29 Time 14:40 Sent To  
Notes
2009-05-29 15:10:48BUILDING PLAN REVIEW
 PERMIT: 090050247
 ADD: 2400 CENTERPARK WEST DR SUITE 125 & 150
 CONT: FISHER CONTRACTING CORP
 TEL: (561) 691-4716
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
 1) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER
 MARCH 1ST, 2009 SHALL BE REVIEWED TO THE 2007 FBC
 BUILDING WITH 2009 SUPPLEMENTS, 2007 EXISTING BUILDING
 CODE WITH 2009 SUPPLEMENTS, PLEASE PROVIDE THE LEVEL OF
 ALTERATION WHICH WILL BE COMPLETED UNDER THIS PERMIT.
 401.4 A DESIGN PROFESSIONAL OR AN OWNER MUST ELECT ONE
 OR A COMBINATION OF LEVELS OF ALTERATION PURSUANT TO
 SECTIONS 403, 404 AND 405 OF THIS CODE. PLEASE UPDATE
 CODE REFRENECED STANDARDS AND PROJECT DATA.
  
 2) DISCREPANCY BETWEEN THE PERMIT APPLICATION
 INDICATING WORK TO BE COMPLETED IN SUITES 125 & 150
 VERSES THE PLANS INDICATING THE WORK TO BE COMPLETED
 UNDER THIS PERMIT IN
 SUITES 101 & 103 PLEASE CORRELATE ADDRESSES AS TO THE
 LOCATION OF WORK.
  
 3) THE NEW FLOOR PLAN LOCATED ON SHEET A2 INDICATES (3)
 NEW "A" TYPE DOORS, NEITHER A2 NOR THE DETAIL ON A3
 INDICATE THE DOOR SIZE OR HARDWARE FOR DOOR TYPE "A".
 11-4.13.5 THE MINIMUM CLEAR DOOR WIDTH (OPENING) 32
 INCHES WITH THE DOOR OPEN 90 DEGREES, MEASURED FROM THE
 FACE OF THE DOOR AND THE OPPOSITE DOOR STOP.
  
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2009-07-05 Cont ID  
Sent By dpalmer Date 2009-07-05 Time 15:20 Rev Time 0.00
Received By dpalmer Date 2009-07-05 Time 15:20 Sent To  
Notes
2009-07-05 15:21:23REDLINED,
  
  
  
 ALL LOW VOLTAGE WORK UNDER SEPARATE PERMIT(S). ANY LV
 ON THESE PLANS MAY BE REFERENCE FOR TURN AORUND PERMIT.
  
 ** ANY REVISIONS AT THE JOB SITE PER BUILDING OFFICIAL
 ARE REQUIRED TO BE DONE BEFORE ROUGH.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2009-05-26 Cont ID  
Sent By dpalmer Date 2009-05-26 Time 10:03 Rev Time 0.00
Received By dpalmer Date 2009-05-26 Time 10:02 Sent To  
Notes
2009-05-26 10:03:09**DENIED **
  
 1) NOTE: PLEASE BE SURE THE FOLLOWING CODES ARE LISTED
 AT A MINIMUM.
 2007 FBC W/ 2009 REVISIONS.
 2006 NFPA-101
  
  
 2) NOTE: PLEASE LABEL ALL MAINS. ONLY ONE IS INDICATED.
 WILL THERE NOW BE A TOTAL OF 6 MAINS? THIS IS WHAT THE
 RISER APPEARS TO SHOW. PLEASE LABEL, 1 OF X, 2 OF X, 3
 OF X ETC. THE 1200 AMP MAIN IS SHOWN 1 OF 4, YET THIS
 APPEARS TO BE THE MAIN TO FEED GUTTER. THE TENANTS
 WOULD BE THEN TENANT MAINS?
 230.2E
  
 3) NOTE: PLEASE INDICATE CONDUCTORS FROM GUTTER TO
 METER AND METER TO NEW TENANT MAIN. PLEASE ALSO
 INDICATE A FLOATING NEUTRAL KIT IS REQUIRED IF THE 1200
 AMP MAIN INDEED FEEDS GUTTER.
 250.6,250.24,310.16,240.4.
  
 4) NOTE: PLEASE INCLUDE THE LOAD ON THE EXISTING MAIN
 WITH THE ADDITION OF THE NEW LOAD FOR TENANT.
 220. PLEASE BE SURE TO SHOW ALL CONTINUOUS LOADS AT
 125%.
  
 5) NOTE: PLEASE SEE CURRENT ADOPTED FLORIDA BUILDING
 CODE CHAPTER 13. A NOTE ON PLANS, MENTIONS THE SCONCES
 ARE NOT INCLUDED PER SECTION CITED. HOWEVER EVEN UNDER
 THE PREVIOUS CODES, THE SCONCES OR DECRETIVE TYPES OF
 FIXTURES WERE NEVER *EXEMPT*. THERE WAS AN ADDITIONAL
 ALLOWANCE FOR THOSE TYPES OF FIXTURE HOWEVER NOT
 EXEMPTED. IN BOTH CASES PLEASE SEE THE NEW ENERGY CODE
 AS THERE IS NO MORE ADDITIONAL ALLOWANCES FOR ANY
 DECRETIVE FIXTURES. ALL MUST BE FIGURED PER
 13-415.AB.5.
 TRADE OFF OF SPACES IS NOT LONGER PERMITTED EITHER.
 PLEASE BE SURE TO SEE THE ADOPTED REVISIONS TO CHAPTER
 13.
  
 6) NOTE: THE UNIT/SUITE NEEDS TO BE DETERMINED AS
 CORRECT. PERMIT APPLICATION STATES 125 AND 150, YET
 PLANS CALL FOR SUITE #103. PLEASE CORRELATE ALL OF
 THESE AND ADJUST AS NEEDED.
 WHEN RE-SUBMITTING PLANS IT IS IMPORTANT TO INDICATE
 THE CORRECTED SUITE NUMBER TO FRONT COUNTER STAFF IN
 ORDER FOR SYSTEM TO BE UPDATED WITH CORRECTED
 INFORMATION.
 FAC 61G15-23.002, 61G1-16.004, FBC 106.5
  
  
  
 * IMPORTANT **
 ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP
 FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE
 ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING.
 DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS.
 PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY
 ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS,
 SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED
 INTO TWO SETS/FOLDERS/BINDERS ETC.
 PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS
 SHOULD BE SUBMITTED FOR REFERENCE.
 THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID
 ANY DELAYS.
  
 IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT
 TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO
 CONTACT THIS REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2009-07-28 Cont ID  
Sent By mawillia Date 2009-07-28 Time 12:33 Rev Time 0.00
Received By mawillia Date 2009-07-28 Time 12:07 Sent To B
Notes
2009-07-28 12:27:37*****APPROVED*****
  
 THE COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEW HAVE
 BEEN ADDRESSED; PLAN SHEETS A-1, A-2, FP-1, E-1, AND
 E-3 WERE STAMPED, INITIALED, AND DATED.
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2009-05-28 Cont ID  
Sent By mawillia Date 2009-05-28 Time 13:48 Rev Time 0.00
Received By mawillia Date 2009-05-28 Time 12:53 Sent To  
Notes
2009-05-28 13:48:14*****DENIED*****
  
 1. THE PROJECT DETAIL AS DESCRIBED ON THE APPLICATION
 IS FOR THE RECONFIGURATION OF SUITES 125 AND 150,
 HOWEVER THE PLANS REFLECT THAT THE PROJECT SCOPE OF
 WORK IS FOR SUITES 101 AND 103. PLEASE
 CORRELATE/CLARIFY.
  
 2. THE ACTUAL SUITE(S) SHALL BE INCLUDED IN THE ADDRESS
 LISTED IN THE TITLE BLOCK OF EACH SUBMITTED PLAN SHEET.
  
 3. ON SHEET T, REFERENCE STANDARDS SHALL BE AS FOLLOWS:
 FLORIDA FIRE PREVENTION CODE 2007 EDITION, NFPA 101 -
 LIFE SAFETY CODE - 2006 EDITION, AND NFPA 1 - UNIFORM
 FIRE CODE - 2006 EDITION.
  
 4. ON SHEET E-2, ELECTRICAL NOTE #2, AMEND EDITION OF
 NFPA 101 FROM 2003 TO 2006.
  
 5. SHOW THE LOCATION OF THE 2A:10BC RATED FIRE
 EXTINGUISHERS WHICH SATISFY THE 75' TRAVEL DISTANCE.
  
  
 TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE
 LETTER INDICATING WHERE EACH ITEM WAS ADDRESSED
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2009-09-10 Cont ID  
Sent By lmartine Date 2009-09-10 Time 12:32 Rev Time 0.00
Received By lmartine Date 2009-09-10 Time 12:32 Sent To  
Notes
2009-09-10 12:32:50GAVE TO JIM W.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2009-06-24 Cont ID  
Sent By shill Date 2009-06-24 Time 14:43 Rev Time 0.00
Received By shill Date 2009-06-24 Time 14:43 Sent To  
Notes
2009-06-24 14:43:44C8
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2009-06-09 Time   Rev Time 0.00
Received By shill Date 2009-05-14 Time 11:23 Sent To PC
Notes
2009-05-14 11:24:09TO COMMERCIAL BOARD #21
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2009-07-20 Cont ID  
Sent By rregueir Date 2009-07-20 Time 16:33 Rev Time 0.00
Received By rregueir Date 2009-07-20 Time 16:23 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2009-06-09 Cont ID  
Sent By rregueir Date 2009-06-09 Time 15:23 Rev Time 0.00
Received By rregueir Date 2009-06-09 Time 15:04 Sent To PC
Notes
2009-06-09 15:23:47REVIEW #: 1ST
 ACTION: DENIED
  
 FBC 2007 CODE FAMILY W/ 2009 SUPPLEMENTS
 FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH
  
 1. SHT 'T' INDICATES THE PLANS WERE DESIGNED TO THE
 2004 FLORIDA BUILDING CODE. ALL PERMITS APPLIED FOR ON
 OR AFTER MARCH 1, 2009 SHALL BE DESIGNED TO THE
 FBC-2007 WITH 2009 SUPPLEMENTS. PLEASE CHANGE THE
 DESIGN REFERENCES AND DESIGN THE PLANS TO CURRENT CODE
 CYCLE. SECTION 106.1.1.
  
 2. APPLICATION INDICATES THE SUITE NUMBERS AS 125 &
 150, BUT THE PLANS SHOW THE PROJECT TO BE IN SUITES 101
 & 103. PLEASE CORRELATE THE APPLICATION INFORMATION
 WITH THE PLAN INFORMATION. SECTION 106.1.1.
  
 3. MECHANICAL PLANS ARE APPROVED BUT REVIEW RESULTS
 WILL REMAIN IN FAILED STATUS UNTIL COMMENTS 1 & 2 ABOVE
 ARE ADDRESSED.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT:
 RONALD J. REGUEIRO
 561.805.6719
 [email protected]

Review Stop P PLUMBING
Rev No 2 Status P Date 2009-07-20 Cont ID  
Sent By kstevens Date 2009-07-13 Time 16:24 Rev Time 0.00
Received By kstevens Date 2009-07-13 Time 16:24 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2009-05-22 Cont ID  
Sent By kstevens Date 2009-05-22 Time 11:01 Rev Time 0.00
Received By kstevens Date 2009-05-22 Time 11:01 Sent To  
Notes
2009-05-22 11:10:02DENIED
 REFERENCE:
 FBC-2007 W/2009 SUPPLEMENTS
 FBC-2007 PLUMBING
 FBC-2007 CHAPTER 1
 FBC-2007 CHAPTER 11
  
 1. SHT 'T' INDICATES THE PLANS WERE DESIGNED TO THE
 2004 FLORIDA BUILDING CODE. ALL PERMITS APPLIED FOR ON
 OR AFTER MARCH 1, 2009 SHALL BE DESIGNED TO THE
 FBC-2007 WITH 2009 SUPPLEMENTS. PLEASE CHANGE THE
 DESIGN REFERENCES AND DESIGN THE PLANS TO CURRENT CODE
 CYCLE. SECTION 106.1.1.
  
 2. APPLICATION INDICATES THE SUITE NUMBERS AS 125 &
 150, BUT THE PLANS SHOW THE PROJECT TO BE IN SUITES 101
 & 103. PLEASE CORRELATE THE APPLICATION INFORMATION
 WITH THE PLAN INFORMATION. SECTION 106.1.1.
  
 3. PLUMBING PLANS ARE APPROVED BUT REVIEW RESULTS WILL
 REMAIN IN FAILED STATUS UNTIL COMMENTS 1 & 2 ABOVE ARE
 ADDRESSED.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]
  