Plan Review Details - Permit 09050228
Plan Review Stops For Permit 09050228 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2009-05-19 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2009-05-19 |
Time |
15:30 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2009-05-19 |
Time |
15:30 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2009-05-14 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2009-05-14 |
Time |
11:53 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2009-05-14 |
Time |
11:53 |
Sent To |
PC |
|
Notes |
2009-05-14 13:04:03 | RESIDENTIAL (R3) RE-ROOFING, BUILDING REVIEW SECOND | | CHECKLIST. | | REVIEW UNDER 2007 FLORIDA RESIDENTIAL CODE WITH 2009 | | REVISIONS. | | | | 1- ENGINEER NEEDS TO REVISE RAS 117 CALCULATIONS. | | SELECTED FLAT ROOF ASSEMBLY ON NOA 08-0226.06 CALLS FOR | | THREE ROWS OF NAILS IN THE CENTER OF SHEET FOR ROOF | | ZONE 1. ENGINEER SPECIFIES TWO ROWS OF NAILS FOR ROOF | | ZONE 1. ENGINEER CAN'T REDUCE THE NUMBER OF NAILS. | | REVISE AS REQUIRED. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ | | (561)805-6712 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2009-05-12 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2009-05-12 |
Time |
17:07 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2009-05-12 |
Time |
17:07 |
Sent To |
PC |
|
Notes |
2009-05-12 17:08:44 | RESIDENTIAL (R3) RE-ROOF, BUILDING REVIEW CHECKLIST. | | REVIEW UNDER 2007 FLORIDA RESIDENTIAL CODE WITH 2009 | | REVISIONS. | | | | 1- ENGINEER TO REVISE RAS 117 CALCULATIONS: | | A) BUILDING IS LOCATED ON EXPOSURE "C" NOT "B" AS | | REQUIRED BY 2009 REVISIONS TO THE 2007 FLORIDA | | RESIDENTIAL CODE. REVISE CALCULATED DESIGN PRESSURES | | ACCORDINGLY. SEE SECTIONS R301.2.1.4 THRU R301.2.1.4.2 | | OF 2009 REVISIONS. | | | | B) NOA 06-0410.06 FILE IS CLOSED BY MIAMI-DADE COUNTY | | PRODUCT APPROVAL DIVISION. SEE ATTACHED COPY FROM DADE | | COUNTY WEBSITE. NEED TO PROVIDE CURRENT PRODUCT | | APPROVAL. | | | | 2- FLAT ROOF PRODUCT APPROVAL FL1654 SUBMITTED ALSO | | REQUIRES CALCULATIONS FOR NAIL ENHANCING DONE BY A | | DESIGN PROFESSIONAL. SEE NOTE #6 OF THE NOTES THAT | | APPLY TO THE SELECTED SYSTEM. SEE ATTACHED COPY FROM | | FLORIDA PRODUCT APPROVAL FL1654-R4. | | **NOTE: USE EITHER THE FLORIDA PRODUCT APPROVAL OR | | CURRENT NOA. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2009-05-12 |
|
|
Cont ID |
|
Sent By |
mmiller |
Date |
2009-05-12 |
Time |
11:39 |
Rev Time |
0.00 |
Received By |
mmiller |
Date |
2009-05-12 |
Time |
11:39 |
Sent To |
|
|
Notes |
2009-05-12 11:39:42 | APPROVED PER JILLIAN PAPA MMILLER |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2009-05-12 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2009-05-12 |
Time |
17:08 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2009-05-12 |
Time |
17:07 |
Sent To |
|
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |