Plan Review Details - Permit 09050218
Plan Review Stops For Permit 09050218
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2009-05-22 Cont ID  
Sent By jgomez Date 2009-05-22 Time 10:50 Rev Time 0.00
Received By jgomez Date 2009-05-22 Time 10:50 Sent To PC
Notes
2009-05-22 10:50:51RECEIVED REVISED INSTALLATION SCHEDULE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By jgomez Date 2009-05-21 Time 11:07 Sent To  
Notes
2009-05-21 11:07:07TALKED TO DIANNE TO GO OVER COMMENTS. SHE SAID JOHN
 WILL CALL ME TO GO OVER COMMENTS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2009-05-13 Cont ID  
Sent By jgomez Date 2009-05-13 Time 15:29 Rev Time 0.00
Received By jgomez Date 2009-05-13 Time 15:29 Sent To PC
Notes
2009-05-13 15:46:33RESIDENTIAL (R3) SHUTTERS, BUILDING REVIEW CHECKLIST.
 REVIEW UNDER 2007 FLORIDA RESIDENTIAL CODE WITH 2009
 REVISIONS.
  
 1- ACCORDION SHUTTERS DRAWINGS NO 05-578 SUBMITTED
 DON'T CORRESPOND TO FLORIDA FL10753-R1 PRODUCT APPROVAL
 SUBMITTED. GO TO WWW.FLORIDABUILDING.ORG TO DOWNLOAD
 CORRESPONDING DRAWINGS TO FLORIDA PRODUCT APPROVAL
 SUBMITTED.
  
 2- REVISE DESIGN PRESSURES CALCULATIONS SUBMITTED.
 ACCORDING TO THE 2009 REVISIONS TO THE 2007 FLORIDA
 RESIDENTIAL CODE, THIS BUILDING IS LOCATED ON EXPOSURE
 "C". SEE REVISED AND NEW SECTIONS R301.2.1.4 THRU
 R301.2.1.4.3 OF 2007 FLORIDA RESIDENTIAL CODE.
  
 3- PROVIDE COMPLETE INSTALLATION SCHEDULE. SEE ATTACHED
 SAMPLE. ALSO, CLEARLY MARK ON SHUTTERS DRAWINGS
 SPECIFIC MOUNTING CONDITIONS (EG: WALL MOUNTED, BUILT
 OUT, ETC) AND SPECIFIC ANCHOR TYPE AND SPACING TO BE
 USED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2009-05-20 Cont ID  
Sent By rmcdouga Date 2009-05-20 Time 16:43 Rev Time 0.00
Received By rmcdouga Date 2009-05-20 Time 16:43 Sent To  
Notes
2009-05-20 16:43:48TO J GOMEZ

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-05-13 Cont ID  
Sent By jgomez Date 2009-05-13 Time 15:59 Rev Time 0.00
Received By jgomez Date 2009-05-11 Time 14:31 Sent To  
Notes
2009-05-13 14:31:33UNDER $ 5000


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved